AKO D14012

AKO D14012 12V Panel-Mounted Digital Temperature Display User Manual

1. Bubuka

This user manual provides detailed instructions for the installation, operation, and maintenance of the AKO D14012 12V Panel-Mounted Digital Temperature Display. This device is designed for precise temperature indication in either Celsius (°C) or Fahrenheit (°F), featuring selectable NTC/PTC probe programs and a simple single-button interface for settings. Please read this manual thoroughly before using the device to ensure correct operation and to prevent damage.

2. Émbaran Kasalametan

  • Kasalametan listrik: Ensure the power supply is disconnected before installation or maintenance. The device operates on 12V DC. Incorrect voltage atanapi polaritasna tiasa ngaruksak unit.
  • Pamasangan: Installation should only be performed by qualified personnel. Follow all local electrical codes and regulations.
  • Lingkungan: Ulah kakeunaan alat ieu ka kalembaban anu kaleuleuwihi, lebu, atanapi suhu anu ekstrim di luar rentang operasi anu ditangtukeun.
  • Penanganan Probe: Handle the temperature probe carefully. Do not bend or crimp the cable excessively.
  • beberesih: Anggo kaén anu lemes sareng garing pikeun beberesih. Ulah make cleaners abrasive atawa pangleyur.

3. Eusi Paket

Pariksa heula sadaya barang aya sareng teu ruksak nalika dibuka bungkusanna:

  • AKO D14012 Digital Temperature Display Unit
  • Temperature Probe (NTC/PTC compatible)
  • Pasang Klip (2 unit)
AKO D14012 digital temperature display unit with probe and mounting clips

Gambar 3.1: Contents of the AKO D14012 package, showing the main display unit, the coiled temperature probe, and two mounting clips.

4. Produk Langkungview

The AKO D14012 is a compact digital temperature display designed for integration into control panels. It features a clear digital display for temperature readings and a single "SET" button for configuration. The unit is powered by 12V DC and connects to an external temperature probe.

4.1. komponén konci

  • Digital tampilan: Némbongkeun suhu ayeuna.
  • Tombol SET: Used to access and adjust device settings and parameters.
  • Probe Input: Connection point for the NTC/PTC temperature sensor.
  • Input kakuatan: Terminals for 12V DC power supply.

5. Setélan

5.1. Pamasangan Panel

The AKO D14012 is designed for panel mounting. Create an opening in your control panel with the following dimensions:

  • lebar: 70.5 mm
  • Jangkungna: 28.5 mm

Insert the display unit into the opening and secure it using the provided mounting clips on the sides of the unit.

Diagram showing panel cutout dimensions 70.5 x 28.5 mm and wiring connections for AKO D14012

Gambar 5.1: Panel cutout dimensions and rear wiring diagram for the AKO D14012 unit.

5.2. Sambungan Wiring

Refer to Figure 5.1 for the wiring diagram. Ensure power is disconnected before making any connections.

  1. Sambungan Probe: Connect the temperature probe to the designated terminals on the left side of the unit (labeled "Sonda" in the diagram).
  2. Sasayogian tanaga: Connect the 12V DC power supply to the terminals on the right side. Ensure correct polarity: connect 12V to the positive terminal and 0V to the negative terminal (labeled "12V=" and "0V" respectively in the diagram). The device is designed for 12V DC operation.

After all connections are made, you can apply power to the unit.

6. Parentah Operasi

6.1. Daya Hurungkeun

Once correctly wired and powered, the display will illuminate and show the current temperature measured by the probe.

6.2. Viewing Suhu

The primary function of the device is to continuously display the temperature. The reading will update automatically as the temperature changes.

6.3. Accessing Settings (SET Button)

The "SET" button is used to access and modify various parameters of the device, such as temperature units (°C/°F) and probe type (NTC/PTC). Specific programming steps will depend on the firmware version. Generally:

  • Pencét pondok: May display a specific parameter or confirm a selection.
  • Pencét Panjang: Typically enters programming mode or saves changes.

Consult the full programming guide for detailed instructions on setting specific parameters, including temperature alarms or calibration, if applicable to your model.

7. Pangropéa

7.1. beberesih

To clean the display unit, gently wipe the surface with a soft, dry, or slightly damp cloth. Do not use harsh chemicals, abrasive cleaners, or solvents, as these can damage the display or casing.

7.2. Probe Inspection

Periodically inspect the temperature probe and its cable for any signs of damage, wear, or corrosion. Replace the probe if any damage is observed to ensure accurate readings.

8. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Teu aya layar / Unit teu tiasa dihurungkeunNo power supply; Incorrect wiring (polarity); Faulty unit.Check 12V DC power connection and polarity. Ensure power source is active. Verify wiring. If problem persists, contact support.
Maca suhu anu salahFaulty probe; Incorrect probe type selected; Probe not properly connected; Environmental interference.Check probe connection. Ensure correct NTC/PTC probe type is configured in settings. Inspect probe for damage. Relocate probe if exposed to external heat sources.
Display shows "Err" or similar error codeProbe disconnected or faulty; Out of temperature range.Check probe connection and integrity. Ensure measured temperature is within -50°C to +150°C range.

9. Spésifikasi

Nomer modélD14012
merekAKO
ProdusénAKO Electronica
Sumber Daya12V DC
Tipe tampilanDigital
Rentang Suhu-50 °C nepi ka +150 °C
Input sénsorNTC Thermistor (PTC selectable)
Tipe PamasanganPanel-dipasang
Panel Cutout Dimensi70.5 mm (Rubak) x 28.5 mm (Jangkungna)
Fitur hususProgrammable, °C/°F selectable

10. Garansi jeung Rojongan

For warranty information, technical support, or service inquiries, please contact your local AKO distributor or the point of purchase. Keep your purchase receipt as proof of purchase for warranty claims.

© 2024 AKO Electronica. All rights reserved.