EARU EARU-1006

EARU Electric Single Phase Énergi Méter 220V 80A Instruksi Manual

Model: EARU-1006

1. Bubuka

The EARU Electric Single Phase Energy Meter (Model EARU-1006) is designed for accurate monitoring of electrical parameters in single-phase 220V, 80A systems. It provides real-time data for voltage (V), current (A), power (W), power factor (PF), frequency (Hz), and kilowatt-hour (kWh) consumption. This device assists in understanding energy usage and identifying potential inefficiencies in your electrical system.

2. Émbaran Kasalametan

  • Pamasangan kedah dilakukeun ku tukang listrik anu mumpuni luyu sareng kode sareng peraturan listrik lokal.
  • Ensure the main power supply is disconnected before installation or maintenance to prevent electric shock.
  • Entong jalankeun alat upami katingalina ruksak.
  • This device is designed for indoor use in a dry environment. Avoid exposure to moisture or extreme temperatures.
  • The maximum current rating is 80A. Do not exceed this limit.

3. Produk Langkungview

The EARU-1006 energy meter features a clear LCD display that shows various electrical parameters simultaneously. It is designed for DIN rail mounting, allowing for easy integration into standard electrical distribution boards.

EARU Electric Single Phase Energy Meter front view kalawan tampilan LCD

Gambar 1: Hareupeun view of the EARU Electric Single Phase Energy Meter, showing the LCD display with various electrical readings.

Close-up of EARU Electric Energy Meter LCD display showing readings

Gambar 2: Detil view of the LCD display, illustrating the layout of voltage, current, power, frequency, power factor, and kWh readings.

4. Eusi Paket

Paket biasana kalebet:

  • 1 x EARU Electric Single Phase Energy Meter (Model EARU-1006)

5. Spésifikasi

Technical data table for EARU Electric Energy Meter

Figure 3: Technical data table providing detailed specifications of the energy meter.

Spésifikasi teknis
ParameterNilai
merekEARU
ModélEARU-1006
Dipeunteun VoltageAC110V/220V (230 Volts)
Dipeunteun Ayeuna80A
Frékuénsi50/60Hz
Akurasi Pangukuran±1% / Class 1
Konsumsi Daya<2W
Pamasangan35mm DIN Rail
Suhu Gawé-10°C nepi ka +55°C
Suhu Panyimpenan-40°C nepi ka +70°C
Kalembaban Gawé5% nepi ka 95% RH
Tipe tampilanLCD
Max kWh Record999999kWh
Dimensi produk10 x 5 x 10 cm
Item Beurat450 g
Dimensions of EARU Electric Energy Meter in millimeters and inches

Figure 4: Dimensional drawing of the energy meter, showing measurements in both millimeters and inches.

6. Setup jeung Instalasi

penting: Pastikeun sadaya kakuatan dipegatkeun sateuacan neraskeun pamasangan.

  1. Pamasangan: The EARU-1006 is designed for 35mm DIN rail mounting. Snap the meter onto the DIN rail securely within your electrical panel.
  2. Wiring: Refer to the wiring diagram below for correct connection. This is a single-phase, 2-wire direct connection meter.
    • Connect the Live (L) input wire to the designated 'L In' terminal.
    • Connect the Neutral (N) input wire to the designated 'N In' terminal.
    • Connect the Live (L) output wire to the designated 'L Out' terminal.
    • Connect the Neutral (N) output wire to the designated 'N Out' terminal.
  3. Daya Hurung: Once all connections are secure and verified, restore power to the circuit. The LCD display should illuminate and begin showing readings.
Wiring diagram for EARU Electric Single Phase Energy Meter

Figure 5: Wiring diagram illustrating the correct connections for the single-phase energy meter.

7. Parentah Operasi

The energy meter operates automatically once powered on. The LCD display continuously cycles through or shows multiple parameters simultaneously.

  • Reading Parameters: The display shows Voltage (V), Current (A), Power (W), Power Factor (PF), Frequency (Hz), and Kilowatt-hour (kWh).
  • kWh Reading: The meter records total kWh consumption. This reading is permanent and accumulates over time.
  • kWh Reset: The meter features a manual reset function for the kWh reading. Consult the device's physical buttons or specific instructions on the meter itself for the reset procedure. Typically, a long press on a designated button (if present) will reset the temporary kWh value. The total kWh value is usually non-resettable.

8. Pangropéa

  • beberesih: Anggo lawon anu garing sareng lemes pikeun ngabersihan bagian luar meter. Ulah make cleaners abrasive atawa pangleyur.
  • Pamariksaan: Periodically inspect the wiring connections to ensure they are tight and free from corrosion.
  • Lingkungan: Pastikeun lingkungan operasi tetep dina kisaran suhu sareng kalembaban anu ditangtukeun.

9. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Paparanana kosongTeu aya catu daya; Kabelna salahCheck power connections and ensure power is supplied. Verify wiring against the diagram.
Bacaan anu salahIncorrect wiring; Faulty connectionDouble-check all wiring connections. Ensure wires are securely fastened.
kWh not accumulatingNo load connected; Meter malfunctionEnsure there is an active electrical load connected through the meter. If problem persists, contact support.

10. Garansi jeung Rojongan

The EARU Electric Single Phase Energy Meter (Model EARU-1006) typically comes with a 1-year warranty from the date of purchase. Please retain your purchase receipt for warranty claims.

For technical support, troubleshooting assistance, or warranty inquiries, please contact your retailer or the manufacturer directly. Refer to the product packaging or manufacturer's websitus pikeun detil kontak.