mypin DA8-RRB

Manual Instruksi Méter Sénsor Digital mypin DA8-RRB

Multi-Functional Intelligent LED Display with 2 Relay Alarm Output

1. Bubuka

The mypin DA8-RRB is a versatile digital sensor meter designed for precise measurement and monitoring of various industrial signals. It features a clear 4-digit LED display for Process Value (PV) and Set Value (SV), and supports multiple input types including 0-75mV, 4-20mA, and 0-10V. Equipped with two relay alarm outputs, this meter provides stable performance and is easy to operate, making it suitable for integration with a wide range of sensors such as transformers, pressure sensors, weighing sensors, and more.

2. Émbaran Kasalametan

  • Always disconnect power before making any wiring connections or performing maintenance.
  • Ensure all wiring is done by qualified personnel and complies with local electrical codes.
  • Pariksa catu daya voltage matches the meter's specifications (90-265V AC/DC).
  • Avoid exposing the device to excessive moisture, dust, or extreme temperatures.
  • Do not attempt to open or repair the device yourself; refer to qualified service personnel.
  • Pastikeun grounding ditangtoskeun pikeun nyegah shock listrik.

3. Produk Langkungview

3.1 Panel payun

Front panel of mypin DA8-RRB Digital Sensor Meter
Figure 1: Front panel showing PV/SV displays, control buttons, and alarm indicators (AL1, AL2, OUT).

The front panel features a large 4-digit LED display for the Process Value (PV) and a smaller 4-digit LED display for the Set Value (SV). Control buttons include SET, <<RST (Reset/Shift), Up arrow, and Down arrow for configuration and operation. Indicators for AL1, AL2 (Alarm 1, Alarm 2), and OUT (Output) are also present.

3.2 Rear Panel and Terminals

Rear panel with terminal block and wiring diagram
Gambar 2: Tukangeun view of the meter, detailing the terminal block for power, input, and output connections, along with product specifications.

The rear panel houses the terminal block for all electrical connections, including power input, auxiliary power, sensor inputs, and relay outputs. A detailed wiring diagram is provided on the label for easy installation.

3.3 Pasang Klip

Samping view of the meter with mounting clips
Gambar 3: Sisi view showing the included mounting clips for panel installation.

The meter comes with mounting clips for secure panel installation. These clips slide into grooves on the side of the meter and are tightened to hold the unit in place.

4. Spésifikasi

ParameterSpésifikasi
ModélDA8-RRB
Sinyal Input0-75mV, 4-20mA, 0-10V
Sasayogian tanaga90-265V AC / DC
Suplai kakuatan bantu24V DC
Konsumsi DayaKirang ti 3W
Akurasi0.3%F.S ±2dgt
Sampling Laju≤8 times/second
Kaluaran Alarm2 x RELAY (Normal Open, AC250V/3A or DC 30V/3A COS=1)
Kaluaran analog4-20mA (Wiring not explicitly shown on provided diagram)
Ukuran (W x H x D)48mm x 96mm x 80mm
Beurat171g
BahanABS

5. Setélan

5.1 Pamasangan

  1. Prepare a panel cutout of appropriate dimensions for the meter (typically 45mm x 92mm, though not explicitly stated, this is standard for 48x96mm meters).
  2. Insert the meter into the panel cutout from the front.
  3. Slide the provided mounting clips into the grooves on the sides of the meter from the rear.
  4. Tighten the screws on the mounting clips to secure the meter firmly in the panel.

5.2 Diagram Wiring

Detailed wiring diagram on the meter's rear label
Figure 4: Close-up of the wiring diagram on the rear label. Refer to this diagram for all electrical connections.

5.3 Sambungan Terminal

Refer to Figure 4 and the following instructions for correct wiring:

Terminal No.KateranganCatetan
1, 2Power Supply (90-265V AC/DC)Connect to main power source.
3, 4Auxiliary Power (24V DC)For external devices or sensors requiring 24V DC.
5, 6Alarm Output 1 (AL1)Relay output, Normally Open (NO). Max AC250V/3A or DC30V/3A.
7, 8Alarm Output 2 (AL2)Relay output, Normally Open (NO). Max AC250V/3A or DC30V/3A.
9Common (com.mV.mA.V)Common terminal for mV, mA, and V inputs.
10mV / mA InputConnect positive terminal of 0-75mV or 4-20mA sensor here.
11Voltage Input (V)Connect positive terminal of 0-10V sensor here.
12Positip (+)Typically for 4-wire sensors or external sensor power.

penting: Ensure correct polarity for all input signals. Incorrect wiring can damage the meter or sensor.

6. Parentah Operasi

6.1 Kakuatan Hurung

After completing all wiring, apply power to the meter. The LED displays will illuminate, showing the current Process Value (PV) and potentially a Set Value (SV).

6.2 Fungsi Tombol

  • Tombol SET: Used to enter parameter setting mode and confirm selections.
  • <<RST button: Used to shift digits during value setting or to reset certain functions.
  • Up (↑) button: Used to increase values or navigate through menu options.
  • Down (↓) button: Used to decrease values or navigate through menu options.

6.3 Basic Operation (General)

While specific programming steps are not detailed in the provided information, typical operation involves:

  1. Viewing PV/SV: The main display shows the current Process Value (PV). The smaller display shows the Set Value (SV), which might be an alarm setpoint or other configured parameter.
  2. Setélan Parameter: Press the SET button to enter the parameter setting mode. Use the Up/Down arrows to select parameters and adjust their values. Use the <<RST button to shift between digits when setting numerical values. Press SET again to confirm and save changes.
  3. Fungsi Alarm: The AL1 and AL2 indicators will light up when the measured PV exceeds or falls below their respective setpoints, triggering the corresponding relay outputs.

For detailed parameter configuration, refer to the full product manual (if available from the manufacturer) or contact technical support.

7. Pangropéa

  • beberesih: Lap layar sareng c lalaunanasing ku lawon anu lemes sareng garing. Ulah make cleaners abrasive atawa pangleyur.
  • Pariksa sambungan: Pariksa sadaya sambungan kabel sacara berkala pikeun mastikeun éta aman sareng bébas tina korosi.
  • Kaayaan Lingkungan: Ensure the operating environment remains within the specified temperature and humidity ranges to prolong the life of the device.

8. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Méter teu hurung.Teu aya catu daya atanapi kabelna salah.Check power connections (Terminals 1, 2) and ensure voltage is within 90-265V AC/DC.
Display shows "----" or erratic readings.Incorrect sensor wiring, sensor malfunction, or wrong input type selected.Verify sensor connections (Terminals 9-12) and ensure the sensor is functioning correctly. Check meter configuration for correct input signal type.
Alarm outputs (AL1/AL2) not activating.Alarm setpoints incorrect or relay wiring issue.Check alarm setpoints (SV) and ensure they are configured correctly relative to the PV. Verify wiring to external alarm devices (Terminals 5-8).
Bacaan teu akurat.Sensor calibration issue or environmental interference.Calibrate the sensor if possible. Ensure the meter is not exposed to strong electromagnetic interference.

9. Tips pamaké

  • Input Signal Selection: Before connecting your sensor, ensure the meter is configured for the correct input signal type (mV, mA, or V) to avoid incorrect readings or potential damage.
  • Hapus Labeling: For complex setups, clearly label all wires connected to the terminal block to simplify future troubleshooting or maintenance.
  • Uji Alarm: After setting alarm points, perform a test to ensure the relay outputs activate as expected.

10. Garansi jeung Rojongan

For warranty information, technical support, or service inquiries, please contact your point of purchase or the manufacturer directly. Keep your purchase receipt as proof of purchase.

Dokumén Patali - DA8-RRB

Praview Manual Instruksi Méter Sensor Cerdas MYPIN Seri D | Spésifikasi & Kabel
Manual instruksi lengkep pikeun MYPIN Seri D Intelligent Sensor Meter. Ngawengku spésifikasi, operasi, setélan parameter, diagram kabel, sareng ngungkulan masalah pikeun modél sapertos DM8A, DK8A, sareng DM8E.
Praview Manual Instruksi Meter Daya Fase Tunggal MYPIN Seri DW - Panduan Téknis
Manual instruksi lengkep pikeun méteran daya fase tunggal MYPIN Seri DW. Ngawengku spésifikasi, operasi, diagram kabel, setélan parameter, sareng aplikasi pikeun pangukuran listrik anu akurat.
Praview Manual Instruksi Pangontrol Timbangan MYPIN Seri LM sareng Pitunjuk Pangguna Modbus
Pituduh lengkep pikeun Pangontrol Timbangan MYPIN LM Series, anu ngawengku pamasangan, operasi, setélan parameter, sareng protokol komunikasi Modbus. Ngawengku spésifikasi lengkep, inpormasi pesenan, sareng diménsi pamasangan.
Praview MYPIN FH Series Méter Intelligent: Frékuénsi, Tacho, Cacah, Angkatan - Spésifikasi Téknis
Spésifikasi téknis komprehensif, fitur, sareng modeu operasional pikeun séri MYPIN FH méter calakan, kalebet fungsi frekuensi, tacho, cacah, sareng angkatan. Dokumén ieu ngécéskeun dimensi, parameter, sareng diagram sambungan.
Praview Manual Instruksi Panghitung/Panjang/Méter Batch MYPIN Seri FH
Manual instruksi pikeun MYPIN FH Series pikeun Counter, Length, sareng Batch Meter. Ngawengku spésifikasi, fitur, urutan, operasi, mode input/output, sareng sambungan terminal pikeun modél FH4, FH7, sareng FH8.
Praview Alat Panghitung Digital sareng Pangukur Panjang MYPIN Seri FH/FC - Spésifikasi sareng Manual
Manual lengkep pikeun counter digital MYPIN Seri FH/FC sareng méter panjang. Spésifikasi lengkep, kode pesenan, operasi, setélan parameter, sareng sambungan terminal pikeun modél FH4, FH6, FH7, FH8, FH9, FH10.