Logo Altronix MaximalLogo Altronix Maximal 2
Leuwih ti saukur power.™
Seri FD maksimal
Dual Power Supply
Pangendali Daya Aksés (PTC)

Maximal FD Series Dual Power Supply Aksés Power Controllers

Model Kalebet:

Maximum 11FD
- Catu daya 1: 12VDC @ 3.3A atanapi 24VDC @ 3.6A.
- Catu daya 2: 12VDC @ 3.3A atanapi 24VDC @ 3.6A.
– Genep belas (16) kaluaran kawates kakuatan PTC-ditangtayungan.
Maximum 33FD
- Catu daya 1: 12VDC @ 5.3A atanapi 24VDC @ 5.6A.
- Catu daya 2: 12VDC @ 5.3A atanapi 24VDC @ 5.6A.
– Genep belas (16) kaluaran kawates kakuatan PTC-ditangtayungan.
Maximum 55FD
- Catu daya 1: 12VDC @ 9.3A.
- Catu daya 2: 12VDC @ 9.3A.
– Genep belas (16) kaluaran kawates kakuatan PTC-ditangtayungan.
Maximum 75FD
- Catu daya 1: 12VDC @ 9.3A.
- Catu daya 2: 24VDC @ 9.6A.
– Genep belas (16) kaluaran kawates kakuatan PTC-ditangtayungan.
Maximum 77FD
- Catu daya 1: 24VDC @ 9.6A.
- Catu daya 2: 24VDC @ 9.6A.
– Genep belas (16) kaluaran kawates kakuatan PTC-ditangtayungan.

Guide instalasi
Altronix Maximal FD Series Dual Power Supply Aksés Power Controllers - sambol 1
Wahyu MDFD052419
Perusahaan Masang: _______________ Nama Perwakilan Layanan: __________________
Alamat: ________________________ No. Telepon: ___________________

MaximalFD Series Leuwihview:

MaximalFD Aksés Power / Controllers ngadistribusikaeun sarta pindah kakuatan pikeun aksés sistem kontrol jeung asesoris. Aranjeunna ngarobah input 120VAC 60Hz kana genep belas (16) bebas dikawasa kaluaran 12VDC atanapi 24VDC PTC-ditangtayungan.
Kaluaran diaktipkeun ku tilelep kolektor kabuka atanapi input pemicu garing biasana kabuka (NO) tina Sistem Kontrol Aksés, Card Reader, Keypad, Tombol Push, PIR, jsb. , Serangan Listrik, Panyekel Panto Magnétik, jsb. Kaluaran bakal beroperasi dina modeu Gagal-Aman sareng/atawa Gagal-Aman. Antarmuka FACP ngaktifkeun Emergency Egress, sareng Alarm Monitoring, atanapi tiasa dianggo pikeun memicu alat bantu anu sanés. Fitur pegatkeun sambungan alarem seuneu tiasa dipilih masing-masing pikeun salah sahiji atanapi sadayana tina dalapan (8) kaluaran.

Bagan Konfigurasi Seri MaximalFD:

Altronix Maximal FD Series Dual Power Supply Aksés Power Controllers - sambol 2

Daptar Agénsi:

UL Listing pikeun
Pamasangan AS: UL 294 * - UL Didaptarkeun pikeun Unit Sistem Kontrol Aksés.
*ANSI/UL 294 7th Ed. Tingkat Kinerja Kontrol Aksés:
Serangan Destructive - I; Daya tahan - I; Kaamanan Jalur - I; Daya stand-by - II, III, IV.

UL Listing pikeun
Pamasangan Kanada: ULC-S319-05 - Sistem Kontrol Aksés Éléktronik Kelas I.
CSA C22.2 No.205 - Equipment sinyal.
ULC-S319-05 Sistem Kontrol Aksés Éléktronik bakal dibatalkeun ku ngagunakeun sagala tambihan, ékspansi, mémori, atanapi modul sanés anu diproduksi ku produsén atanapi pabrikan sanés.

Keunggulan Seri MaximalFD:

Modul Kontrol Daya Aksés ACM8CB:

  • Genep belas (16) bebas pemicu kaluaran dikawasa. Pilihan kaluaran:
    a) Genep belas (16) kaluaran kakuatan disaring Gagal-Aman.
    b) Genep belas (16) kaluaran kakuatan disaring Gagal-Aman.
    c) Sakur kombinasi di luhur.
  • genep belas (16) Aksés Control System micu inputs. Pilihan pemicu input:
    a) Genep belas (16) biasana muka (NO) input pemicu garing.
    b) Genep belas (16) input collector kabuka.
    c) Sakur kombinasi di luhur.
  • Genep belas (16) aux disaring unswitched. kaluaran kakuatan (output dipeunteun @ 2.5A).
  • LEDs beureum dina dewan ACM8CB nunjukkeun kaluaran individu dipicu (relays energized).
  • Pegatkeun sambungan Alarm Seuneu (latching atanapi non-latching) bisa dipilih individual pikeun salah sahiji atawa sakabéh genep belas (16) kaluaran.
    Alarm seuneu pegatkeun sambungan pilihan pemicu input:
    a) Biasana kabuka (NO) atanapi normal ditutup (NC) input pemicu garing.
    b) Input ngabalikeun polaritasna tina sirkuit sinyal FACP.
  • Héjo LED dina dewan ACM8CB nunjukkeun FACP megatkeun sambungan dipicu.
  • Relay kaluaran FACP nunjukkeun yén input FACP dipicu (bentuk kontak "C" dipeunteun @ 1A / 28VDC henteu dievaluasi ku UL).
  • eFlow Power Supply / Charger nyadiakeun kakuatan umum pikeun dewan ACM8CB (wiring pabrik) jeung sakabeh alat kontrol aksés disambungkeun (wiring sawah).
  • sekering utama dewan ACM8CB dipeunteun @ 10A. PTCs kaluaran dipeunteun @ 2.5A.

eFlow Power Supply/Charger:

  • Input: 120VAC, 60Hz.
  • Pikeun kaluaran voltage jeung suplai ayeuna tingal Bagan Konfigurasi runtuyan MaximalFD, pg. 3.
  • Kelas Auxiliary 2 Power-Limited output dipeunteun @ 1A (unswitched).
  • Overvoltage panyalindungan.
  • Carjer diwangun-di pikeun asam kalungguhan disegel atanapi accu tipe gél.
  • muatan maksimum ayeuna 1.54A.
  • Pindah otomatis kana batré stand-by nalika AC gagal. Transfer ka daya batre stand-by sakedapan tanpa gangguan.
  • Diawasan Alarm Seuneu megatkeun sambungan (latching atanapi non-latching) 10K EOL résistor. Beroperasi dina pemicu normally open (NO) atawa normally closed (NC).
  • AC gagal pangawasan (bentuk kontak "C").
  • Batré gagal & pangawasan ayana (bentuk kontak "C").
  • shutdown kakuatan low. Mareuman terminal kaluaran DC lamun vol batrétage turun di handap 71-73% pikeun unit 12V sareng 70-75% kanggo unit 24V (gumantung kana catu daya). Nyegah ngaleupaskeun batré jero.
  • Pikeun sekering, ratings tingal Bagan Konfigurasi runtuyan MaximalFD, pg. 3.
  • Héjo AC Power LED nunjukkeun 120VAC hadir.
  • Input AC sareng kaluaran DC indikator LED.
  • sirkuit pondok tur panyalindungan overload.
  • Kandang nampung nepi ka opat (4) batré 12VDC/12AH.
    Dimensi kandang (H x W x D): 26" x 19" x 6.25" (660.4mm x 482.6mm x 158.8mm).

Parentah Instalasi MaximalFD:

Métode wiring kedah saluyu sareng Kode Listrik Nasional / NFPA 70 / ANSI, Kode Listrik Kanada, Bagian I, Bagian II, sareng sadaya kode lokal sareng otoritas anu gaduh yurisdiksi. Produk dimaksudkeun pikeun pamakéan jero rohangan wungkul.

Power Supply Board LED Diagnostics (kaca. 7)
Aksés Power Controller LED Diagnostics (kaca. 7)
Power Supply Board Stand-by spésifikasi batré (kaca. 7)
Idéntifikasi Terminal Power Supply Board (kaca. 8)
Aksés Power Controller Terminal Identification (kaca. 8)
Power Supply Board Kaluaran Voltage Setélan (kaca. 9)
Aksés Power Controller Diagram Aplikasi Khas (kaca. 9)
FACP / Pilihan Power Supply diagram Hook-up (kaca. 12)
  1. Pasang unit di lokasi anu dipikahoyong. Cirian jeung predrill liang dina témbok pikeun baris nepi ka luhur tilu keyholes di dipager nu. Pasang tilu fasteners luhur jeung screws dina témbok jeung huluna screw protruding. Teundeun keyholes luhur dipager urang ngaliwatan tilu screws luhur, tingkat, jeung aman. Cirian posisi tilu liang handap. Leupaskeun kandang. Bor liang handap tur masang tilu fasteners. Teundeun keyholes luhur dipager urang ngaliwatan tilu screws luhur. Pasang tilu screws handap sarta pastikeun pikeun tighten sadayana screws (Diménsi dipager, pg. 15).
  2. Sambungkeun kakuatan AC unswitched (120VAC 60Hz) ka terminal ditandaan [L, N] (Gbr. 3, pg. 10). Héjo "AC" LED dina dewan catu daya bakal ngahurungkeun. Cahaya ieu tiasa ditingali tina lénsa LED dina panto kandang. Anggo 14 AWG atanapi langkung ageung pikeun sadaya sambungan listrik. Kawat héjo aman nuju kana taneuh bumi.
    Tetep wiring kawates kakuatan misah ti wiring non-daya kawates. Minimum 0.25 "spasi kudu disadiakeun (Gbr. 3, pg. 10).
    PERHATOSAN: Ulah noél bagian logam kakeunaan. Pareuman kakuatan sirkuit cabang sateuacan masang atanapi ngalayanan peralatan. Henteu aya bagian anu tiasa dilayanan ku pangguna di jero.
    Rujuk pamasangan sareng ngalayanan ka tanaga jasa anu mumpuni.
  3. Pilih vol kaluaran DC anu dipikahoyongtage ku netepkeun SW1 ka posisi luyu dina dewan catu daya (Maximal11FD na Maximal33FD), (Gbr. 1, pg. 9). catu daya Maximal55FD diatur pabrik dina 12VDC. Catu daya Maximal77FD diatur pabrik dina 24VDC. Maximal75FD diwangun ku hiji (1) papan catu daya anu diatur pabrik dina 12VDC, sareng hiji (1) papan catu daya anu diatur pabrik dina 24VDC.
  4. Ukur kaluaran voltage tina unit saméméh nyambungkeun sagala alat pikeun mastikeun operasi ditangtoskeun. Teu pantes atawa luhur voltage bakal ngaruksak alat ieu.
  5. Pilihan kaluaran (Gbr. 2, pg. 9):
    Unit bakal nyadiakeun boh genep belas (16) outputs kakuatan switched, genep belas (16) formulir garing "C" outputs, atawa kombinasi mana wae duanana switched kakuatan sarta formulir "C" outputs.
    (a) Kaluaran Kakuatan Gagal-Aman: Kanggo operasi Gagal-Aman sambungkeun input positip (+) tina alat kontrol aksés ka terminal anu ditandaan.
    [NC]. Sambungkeun input négatip (-) alat kontrol aksés ka terminal anu ditandaan [COM].
    (b) Kaluaran Kakuatan Saklar Aman-Gagal:
    Pikeun operasi Gagal-Aman sambungkeun positif (+) input alat kontrol aksés ka terminal ditandaan [NO]. Sambungkeun input négatip (-) alat kontrol aksés ka terminal anu ditandaan [COM].
  6. Kaluaran Daya Bantu ACM8CB (teu diswitch):
    Sambungkeun alat kontrol aksés nu merlukeun kakuatan konstan ka terminal ditandaan [C] positif (+) jeung [COM] négatip (-).
    Kaluaran bantu eFlow (teu diswitch):
    Pikeun sambungan alat bantu, kaluaran ieu moal kapangaruhan ku Low Power Disconnect atanapi Seuneu Alarm Interface. Sambungkeun alat ka terminal ditandaan [+ AUX -] (Gbr. 3, pg. 10).
  7. Pilihan pemicu input (Gbr. 2, pg. 9):
    (a) Biasana Buka pemicu input [NO]:
    Input 1-8 diaktipkeun ku input tilelep kolektor biasana kabuka atanapi kabuka. Sambungkeun kaluaran panel kontrol aksés, keypads, tombol push, REX PIRs, jsb ka terminal ditandaan [IN] jeung [GND].
    (b) Input Open Collector Sink:
    Sambungkeun panel kontrol aksés kabuka collector tilelep positif (+) ka terminal ditandaan [IN] jeung négatip (-) ka terminal ditandaan [GND].
  8. Pilihan Interface Alarm Seuneu ACM8CB (Gbr. 5-9, pg. 12):
    Pemicu input [NC] biasana ditutup atanapi buka [NO] biasana tina panel kontrol alarem seuneu atanapi input ngabalikeun polaritasna tina sirkuit sinyal FACP bakal mangaruhan kaluaran anu dipilih. Pikeun Aktipkeun FACP Pegatkeun pikeun kaluaran ngahurungkeun switch pakait (es) [SW1-SW8] OFF on unggal dewan ACM8CB. Pikeun nganonaktipkeun FACP pegatkeun pikeun kaluaran ngahurungkeun switch pakait (es) [SW1-SW8] ON on unggal dewan ACM8CB.
    (a) Biasana Buka input [NO]:
    Pikeun non-latching hook-up tingal Gbr. 6, pg. 12. Pikeun latching hook-up tingal Gbr. 7, pg. 12.
    (b) Input [NC] Biasana Ditutup:
    Pikeun non-latching hook-up tingal Gbr. 8, pg. 12. Pikeun latching hook-up tingal Gbr. 9, pg. 12.
    (c) Pemicu input Sirkuit Sinyal FACP:
    Sambungkeun positip (+) sareng négatif (-) tina kaluaran sirkuit sinyal FACP ka terminal anu ditandaan [+ INP -]. Sambungkeun FACP EOL ka terminal anu ditandaan [+ RET –] (polaritas dirujuk dina kaayaan alarm). Jumper lokasina gigireun TRG LED kudu motong (Gbr. 2a, pg. 9 jeung Gbr. 6, pg. 12).
  9. FACP formulir garing "C" kaluaran (teu dievaluasi ku UL) (Gbr. 2b, pg. 9):
    Kontak formulir "C" FACP tiasa dianggo pikeun memicu alat ngalaporkeun atanapi sinyal. Kontak ieu pindah kana pemicu input alarem seuneu ka papan ACM8CB.
  10. Sambungan Batré Stand-by (Gbr. 3, pg. 10):
    Pikeun aplikasi AS Access Control, batréna opsional. Batré dipikabutuh pikeun pamasangan Kanada (ULC-S319). Nalika accu teu dipaké, leungitna AC bakal ngakibatkeun leungitna kaluaran voltage. Nalika nganggo batré stand-by anu dipikahoyong, aranjeunna kedah janten asam timah atanapi jinis gél. Sambungkeun batré ka terminal ditandaan [- BAT +] (Gbr. 3, pg. 10). Anggo dua (2) batré 12VDC dihubungkeun sacara séri pikeun operasi 24VDC (kaasup batréna). Paké accu - Castle CL1270 (12V / 7AH), CL12120 (12V / 12AH), CL12400 (12V / 40AH), CL12650 (12V / 65AH) accu atawa UL-dipikawanoh BAZR2 na BAZR8 batré tina hiji rating luyu.
  11. Batré sareng Output Pengawasan AC (Gbr. 3, pg. 10):
    Diperlukeun pikeun nyambungkeun alat ngalaporkeun masalah pengawasan ka kaluaran anu ditandaan [AC Fail, BAT Fail] sareng output relay pengawasan anu ditandaan [NC, C, NO] kana alat bewara visual anu luyu. Anggo 22 AWG dugi ka 18 AWG pikeun AC Gagal sareng ngalaporkeun Lemah / Henteu Batré.
  12. Pikeun reureuh ngalaporkeun AC salila 2 WIB, Setel saklar DIP [AC Delay] ka posisi OFF (Gbr. 3, pg. 10).
    Pikeun reureuh laporan AC pikeun 1 mnt., Nyetél saklar DIP [Tunda AC] ka posisi ON (Gbr. 3, pg. 10).
  13. Pareum Daya Lemah (Gbr. 3, pg. 10):
    Pikeun ngaktipkeun Low Output Power Shutdown, setel saklar DIP [Shutdown] ka posisi ON.
    Pikeun nganonaktipkeun Low Output Power Shutdown, setel saklar DIP [Shutdown] ka posisi OFF.
  14. Pamasangan Tamper Switch (Gbr. 3a, pg. 10):
    Gunung UL Didaptarkeun tamper switch (model Altronix TS112 atawa sarimbag) dina luhureun dipager nu. Ngageser tamper switch bracket onto ujung dipager kira 2 "ti sisi katuhu (Gbr. 3a, pg. 10). Nyambungkeun tamper switch wiring ka input Control Panel Aksés atawa alat ngalaporkeun UL Listed luyu. Pikeun ngaktipkeun sinyal alarm, buka panto kandang.
  15. Sababaraha inputs catu daya (Gbr. 2, pg. 9) (Teu dievaluasi ku UL):
    Lamun ngagunakeun catu daya éksternal didaptarkeun tambahan, jumpers J1 na J2 lokasina dina dewan ACM8CB pakait kudu motong (Gbr. 2c, pg. 9 jeung Gbr. 5, pg. 12). Sambungkeun catu daya kontrol aksés kawates Daya Terdaptar éksternal ka terminal anu ditandaan [– Control +] (Terminal ieu disajajarkeun sareng terminal [– Power +]). Nalika nganggo catu daya DC, polaritasna kedah diperhatoskeun. Nalika nganggo catu daya AC, polaritasna henteu kedah diperhatoskeun (Gbr. 2d, pg. 9). Kabéh sambungan wiring widang kudu dilakukeun employing cocok gauge CM atanapi FPL jacketed kawat (atawa diganti sarimbag) (Gbr. 4a, pg. 11).

Pangropéa:

Unit kedah diuji sahenteuna sakali sataun pikeun operasi anu leres sapertos kieu:

Pengawasan FACP: Pikeun mastikeun sambungan ditangtoskeun jeung operasi tina Seuneu Alarm megatkeun hookup.
Mangga tuturkeun prosedur anu luyu di handap ieu:
Biasana Buka Input: Nempatkeun pondok antara terminal ditandaan [T] jeung [+ INP] bakal pemicu nu
Seuneu Alarm Pegatkeun sambungan. Leupaskeun pondok pikeun ngareset.
 Input Biasana Ditutup: Nyoplokkeun kawat ti terminal ditandaan [INP -] bakal memicu Alarm Seuneu
Pegatkeun sambungan. Ganti kawat ka terminal anu ditandaan [INP –] pikeun ngareset.
Input Sirkuit Sinyal FACP: Ieu diperlukeun pikeun memicu Sistim Alarm Seuneu. Dina sadaya skénario di luhur, TRG LED héjo tina ACM8CBs bakal nyaangan. Sadaya kaluaran anu dipilih pikeun Pegatkeun Alarm seuneu bakal ngaktipkeun ngaleupaskeun alat konci.

Catetan: Sadaya kaluaran [OUT 1] - [OUT 8] kedah dina kaayaan normal (de-energized) sateuacan diuji. Nalika unit ieu ngonpigurasi pikeun Normally Buka (Gbr. 8, pg. 12) atanapi Normally Closed (Gbr. 10, pg. 12) operasi latching, perlu ngareset Seuneu Alarm Pegatkeun sambungan ku ngaktipkeun switch reset Normally Closed.

Kaluaran Voltage Tes: Dina kaayaan beban normal, kaluaran DC voltage kudu dipariksa pikeun vol ditangtoskeuntage tingkat (ningali MaximalFD runtuyan Bagan Konfigurasi, pg. 3).
Tés batré: Dina kaayaan beban normal pariksa yen batréna geus dicas pinuh, pariksa vol dieusiantage di terminal batré jeung di terminal dewan ditandaan [+ BAT –] pikeun mastikeun yén euweuh putus dina kawat sambungan batré.

Catetan: Arus muatan maksimum nyaéta 1.54A. Harepan umur batre nyaéta 5 taun; kumaha oge, eta disarankeun pikeun ngaganti accu dina 4 taun atawa kirang lamun perlu.
Diagnostik LED Power Supply Board:

Beureum (DC) Héjo (AC/AC1) Status catu daya
ON ON Kaayaan operasi normal.
ON Pareum Leungitna AC. batré stand-by nyadiakeun kakuatan.
Pareum ON Taya kaluaran DC.
Pareum Pareum Leungitna AC. Discharged atawa euweuh batré stand-by. Taya kaluaran DC.
Beureum (Kalong) Status Batré
ON Kaayaan operasi normal.
Pareum Batré gagal / batré lemah.

Diagnostik LED Controller Daya Aksés:

LED ON Pareum
LED 1- LED 8 (Beureum) Relay kaluaran (s) energized. Relay kaluaran (s) de-energized.
Trg (Héjo) Input FACP dipicu (kaayaan alarem). FACP normal (kondisi non-alarm).

Spésifikasi Batré Stand-by Power Supply Board:

Batré Maximum 11FD Maximum 33FD Maximal55FD, Maximal75FD, sarta Maximal77FD
7AH 30 Menit/4A* 10 Menit/6A 5 Menit/10A
12AH 35 Menit/4A* 30 Menit/6A* 30 Menit/10A*
40AH Leuwih 4 Jam/4A* Leuwih 4 Jam/6A* Leuwih 2 Jam/10A*
65AH Leuwih 4 Jam/4A* Leuwih 4 Jam/6A* Leuwih 4 Jam/10A*

* Ngan konfigurasi ieu tiasa dianggo dina pamasangan ULC-S319.

Idéntifikasi Terminal Power Supply Board:

Katerangan Terminal Fungsi / Katerangan
L, G, N Sambungkeun 120VAC 60Hz ka terminal ieu: L ka panas, N ka nétral. Entong nganggo terminal anu ditandaan [G].
+ DC - Pabrik disambungkeun ka dewan ACM8.
Pemicu EOL diawasan Seuneu Alarm Interface pemicu input ti pondok atawa FACP. Input pemicu tiasa biasana kabuka, biasana ditutup tina sirkuit kaluaran FACP (input kawates kakuatan kelas 2) (Gbr. 3, pg. 10).
HENTEU, GND RESET panganteur FACP latching atanapi non-latching (Kelas 2 kakuatan kawates) (Gbr. 3, pg. 10).
+ AUX- Kelas bantu 2 kaluaran kawates kakuatan dipeunteun @ 1A (unswitched) (Gbr. 3, pg. 10).
AC GAGAL NC, C, NO Nunjukkeun leungitna kakuatan AC, misalna nyambung ka alat karungu atawa panel alarm. Relay biasana dihurungkeun nalika kakuatan AC aya.
Rating kontak 1A @ 30VDC (Kakuatan kelas 2 kawates) (Gbr. 3, pg. 10).
 

BAT GAGAL NC, C, NO

Nunjukkeun kaayaan batre lemah, misalna nyambung ka panel alarm. Relay biasana dibangkitkeun nalika kakuatan DC aya. Kontak rating 1A @ 30VDC.
Batré anu dicabut dilaporkeun dina 5 menit.
Sambungan deui batré dilaporkeun dina 1 menit (Kakuatan kelas 2 kawates) (Gbr. 3, pg. 10).
+ BAT- Sambungan batré stand-by.
muatan maksimum ayeuna 1.54A (non-kakuatan-kawas) (Gbr. 3, pg. 10).

Aksés Power Controller Terminal Idéntifikasi:

Katerangan Terminal Fungsi / Katerangan
- Kakuatan + 12VDC atanapi 24VDC tina catu daya / carjer (pabrik disambungkeun). Terminal ieu sajajar jeung terminal [– Control +].
 - Kontrol + Terminal ieu sajajar jeung terminal [- Power +].
Terminal-terminal ieu tiasa dihubungkeun ka catu daya kontrol aksés kawates anu didaptarkeun éksternal pikeun nyayogikeun kakuatan operasi terasing pikeun alat-alat (Teu dievaluasi ku UL). Jumpers J1 jeung J2 kudu dihapus.
INPUT pemicu 1- input 8 IN, GND Tina input pemicu anu biasana dibuka sareng / atanapi kabuka kolektor tilelep (nyuhunkeun tombol kaluar, pasangan kaluar, jsb.)
 

 

 

 

 

OUTPUT 1- OUTPUT 8 NC, C, NO, COM

12VDC mun 24VDC pemicu dikawasa outputs. Beban maksimum per kaluaran nyaéta 2.5A.
Maximal11FD: P/S 1 – 9.8-13.2VDC @ 3.3AP/S 2 – 9.8-13.2VDC @ 3.3A atawa P/S 1 – 19.9-26.4VDC @ 3.6AP/S 2 – 19.9-26.4VDC atawa @ 3.6VDC P / S 1 - 9.8-13.2VDC @ 3.3A jeung P / S 2 - 19.9-26.4VDC @ 3.6A.
Maximal33FD: P/S 1 – 9.7-13.2VDC @ 5.3AP/S 2 – 9.7-13.2VDC @ 5.3A atawa P/S 1 – 19.8-26.4VDC @ 5.6AP/S 2 – 19.8-26.4VDC atawa @ 5.6VDC P / S 1 - 9.7-13.2VDC @ 5.3A jeung P / S 2 - 19.8-26.4VDC @ 5.6A.
Maximal55FD: P / S 1 - 9.7-13.2VDC @ 9.3A jeung P / S 2 - 9.7-13.2VDC @ 9.3A.
Maximal75FD: P / S 1 - 9.7-13.2VDC @ 9.3A jeung P / S 2 - 19.8-26.4VDC @ 9.6A.
Maximal77FD: P / S 1 - 19.8-26.4VDC @ 9.6A jeung P / S 2 - 19.8-26.4VDC @ 9.6A.
Gagal-Aman [NC positif (+) & COM Négatip (-)], Gagal-Aman [NO positif (+) & COM Négatip (-)], Auxiliary kaluaran [C positif (+) & COM Négatip (-)].
Nalika nganggo catu daya AC polaritasna henteu kedah diperhatoskeun. Kontak dipintonkeun dina kaayaan teu dipicu.
Panganteur FACP T, + INPUT Seuneu Alarm Interface pemicu input ti FACP. Input pemicu tiasa biasana kabuka, biasana ditutup tina kaluaran sirkuit sinyal FACP (Gbr. 5-9, pg. 12).
Panganteur FACP NC, C, NO Bentuk kontak relay "C" dipeunteun @ 1A 28VDC pikeun ngalaporkeun alarm (henteu dievaluasi ku UL).

Power Supply Board Kaluaran Voltage Setélan:

Altronix Maximal FD Series Dual Power Supply Access Power Controllers - Gbr 1

Aksés Power Controller Diagram Aplikasi Khas (pikeun unggal ACM8CB):

Altronix Maximal FD Series Dual Power Supply Access Power Controllers - Gbr 2

Altronix Maximal FD Series Dual Power Supply Access Power Controllers - Gbr 3

PERHATOSAN: Nalika papan catu daya disetel pikeun 12VDC, ngan ukur nganggo hiji (1) batré stand-by 12VDC.
Tetep wiring kawates kakuatan misah ti non-daya kawates. Paké spasi minimum 0.25″.
Batré 12AH anu tiasa dicas deui mangrupikeun batré anu panggedéna anu tiasa pas dina kandang ieu. Panutup batré éksternal anu didaptarkeun UL kedah dianggo upami nganggo batré 40AH atanapi 65AH.

Syarat Wiring Terbatas Daya NEC:

Kakuatan kawates sarta non-kakuatan kawates circuit wiring kudu tetep dipisahkeun dina kabinet. Sadaya kabel sirkuit kawates kakuatan kedah tetep sahenteuna 0.25 "jauh tina kabel sirkuit anu teu kawates kakuatan. Saterusna, sadaya wiring circuit kawates kakuatan sarta non-daya kawates circuit wiring kudu asup jeung kaluar kabinet ngaliwatan conduits béda.
Hiji mantan sapertosample tina ieu ditémbongkeun di handap. Aplikasi husus Anjeun bisa jadi merlukeun knockouts conduit béda pikeun dipaké. Sakur knockouts conduit tiasa dianggo. Pikeun aplikasi kakuatan-watesan pamakéan conduit nyaeta pilihan. Sadaya sambungan kabel sawah kedah dilakukeun nganggo gauge CM atanapi kawat jaket FPL (atanapi pengganti anu sarimbag).
The UL Listed dipager batré pilihan kudu dipasang padeukeut jeung catu daya via métode wiring Kelas 1. Pikeun pamasangan Kanada nganggo kabel shielded pikeun sakabéh sambungan.
Catetan: Tingal gambar penanganan kawat di handap pikeun cara ditangtoskeun masang CM atawa FPL jacketed kawat (Gbr. 4a).

Altronix Maximal FD Series Dual Power Supply Access Power Controllers - Gbr 4

Diagram Hook-Up FACP:

Altronix Maximal FD Series Dual Power Supply Access Power Controllers - Gbr 5

Catetan:…..

Altronix Maximal FD Series Dual Power Supply Access Power Controllers - Gbr 6

Logo Altronix Maximal 2

eFlow Power Supply / Chargers tiasa
Dikadalikeun sareng diawaskeun nalika ngalaporkeun
Daya / Diagnostik ti mana
liwat Jaringan…

Altronix Maximal FD Series Dual Power Supply Access Power Controllers - Gbr 7

LINQ2 - Modul Komunikasi Jaringan
LINQ2 nyadiakeun aksés IP jauh ka data real-time tina catu daya / chargers eFlow pikeun mantuan tetep sistem nepi na ngajalankeun di tingkat optimal. Ieu facilitates gancang jeung gampang instalasi tur nyetel-up, ngaminimalkeun downtime sistem, sarta eliminates nelepon jasa teu perlu, nu mantuan ngurangan Total Cost of Kapamilikan (TCO) - kitu ogé nyieun sumber anyar panghasilan Bulanan ngulang (RMR).

Fitur:
- UL didaptarkeun di AS sareng Kanada.
– Kadali lokal atawa jauh nepi ka (2) dua kaluaran kakuatan Altronix eFlow ngaliwatan LAN jeung/atawa WAN.
- Monitor diagnostik sacara real-time: kaluaran DC voltage, arus kaluaran, status/layanan AC & batré, parobahan kaayaan pemicu input, parobahan kaayaan kaluaran, jeung suhu unit.
- Kontrol aksés sareng manajemén pangguna: Watesan maca / nyerat, Watesan pangguna pikeun sumber khusus
- Dua (2) jaringan integral dikawasa Bentuk "C" Relays.
- Tilu (3) pemicu input anu tiasa diprogram: Kontrol relay sareng catu daya ngalangkungan sumber hardware éksternal.
- Bewara Surélék sareng Windows Dashboard
- Log acara ngalacak sajarah.
- Lapisan Socket Aman (SSL).
- Programmable via USB atawa web browser - ngawengku software operasi sarta 6 ft. kabel USB.

LINQ2 Mounts Di jero sagala MaximalF dipager

Altronix Maximal FD Series Dual Power Supply Access Power Controllers - Gbr 8

Logo Altronix Maximal 3

Maximal11FD/33FD/55FD/75FD/77FD Series Access Power Controllers (PTC) Pituduh Instalasi
Altronix teu nanggungjawaban kanggo sagala kasalahan tipografi.
140 58th Street, Brooklyn, York énggal 11220 AS | telepon: 718-567-8181 | fax: 718-567-9056
websitus: www.altronix.com | e-mail: info@altronix.com | Garansi saumur hirup
IIMaximal11FD/33FD/55FD/75FD/77FD Series
H11U

Dokumén / Sumberdaya

Altronix Maximal FD Series Dual Power Supply Aksés Power Controllers [pdf] Pituduh instalasi
Maksimal FD Series Dual Power Supply Aksés Power Controllers, Maximal FD Series, Dual Power Supply Aksés Power Controllers, Dual Power Supply, Aksés Power Controllers Power Supply, Aksés Power Controllers, Power Supply, Maximal11FD, Maximal33FD, Maximal55FD, Maximal75FD, Maximal77FD

Rujukan

Ninggalkeun komentar