Maxtec R217P42

Maxtec MAXO2+ Oxygen Analyzer User Manual

Model: R217P42

1. Bubuka

The Maxtec MAXO2+ Oxygen Analyzer is a portable device designed for accurate measurement of oxygen concentration. It is commonly used in various applications, including checking oxygen levels in scuba tanks, medical oxygen sources, and other gas mixtures. This manual provides essential information for the safe and effective use of your analyzer.

2. Émbaran Kasalametan

Please read and understand all safety warnings and instructions before operating the device. Failure to do so may result in injury or damage to the product.

3. Eusi Paket

Pastikeun yén sadaya item aya dina pakét anjeun:

4. Produk Langkungview

The MAXO2+ Oxygen Analyzer features a compact design with an easy-to-read digital display. Key components include:

Maxtec MAXO2+ Oxygen Analyzer showing 20.9% oxygen reading

Figure 1: Maxtec MAXO2+ Oxygen Analyzer with digital display showing 20.9% oxygen.

5. Setup jeung Pamakéan Awal

Follow these steps to prepare your analyzer for use:

  1. Pasang Batré:
    • Locate the battery compartment cover on the back of the analyzer.
    • Use the provided small screwdriver to unscrew the retaining screws and remove the cover.
    • Selapkeun 3 batré AAA, mastikeun polaritasna bener.
    • Ganti panutup sarta amankeun ku screws.
  2. Install Oxygen Sensor:
    • The oxygen sensor is typically packaged separately to prevent premature exposure to air.
    • Unscrew the cap from the sensor port at the bottom of the analyzer.
    • Carefully remove the new oxygen sensor from its protective packaging.
    • Screw the sensor into the sensor port until it is finger-tight. Do not overtighten.
  3. Attach T-Piece Adapter:
    • The T-piece adapter allows for sampling from various gas sources.
    • Firmly push the T-piece adapter onto the top port of the analyzer.
    • If using tubing for inline sampling, connect one end of the tubing to one side of the T-piece.

Video 1: Demonstration of the Oxygen Analyzer's features, T-piece attachment, and sampprosés ling.

6. Parentah Operasi

To ensure accurate readings, proper operation and calibration are crucial.

  1. Daya Hurung: Press the power button (usually marked with an 'I' or power symbol) to turn on the analyzer. The display will illuminate and show the current oxygen concentration.
  2. Calibration (Fresh Air):
    • Before each use, or if the device has been stored for a long time, calibrate the analyzer in fresh air (20.9% oxygen).
    • Ensure the T-piece is open to ambient air, or no gas source is connected.
    • Press and hold the calibration button (often marked with a 'CAL' or similar symbol) until the display shows "20.9%" or indicates successful calibration. Some models may have a one-button calibration feature.
    • Ngidinan bacaan pikeun nyaimbangkeun.
  3. Nyokot pangukuran:
    • Connect the T-piece adapter to your oxygen source (e.g., scuba tank valve, oxygen concentrator outlet). For scuba tanks, ensure a snug fit with the rubberized dome.
    • Slowly open the valve of the oxygen source to allow gas to flow through the T-piece and over the sensor.
    • Observe the digital display for the oxygen concentration reading. Allow a few seconds for the reading to stabilize.
    • Once the reading is stable, note the measurement.
    • Close the oxygen source valve and disconnect the analyzer.
  4. Pareum listrik: Pencét terus tahan tombol daya nepi ka layar pareum.

7. Pangropéa

Regular maintenance ensures the longevity and accuracy of your MAXO2+ Oxygen Analyzer.

8. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Alat teu hurung.Batré paéh atawa salah dipasang.Ganti batré, mastikeun polaritasna bener.
Bacaan anu teu akurat atanapi teu teratur.Sensor needs calibration, old sensor, or sensor not properly installed.Perform fresh air calibration. If problem persists, replace the sensor. Ensure sensor is tightly screwed in.
Calibration fails.Sensor is at the end of its life, or calibration environment is not fresh air.Replace the oxygen sensor. Ensure calibration is performed in an area with known 20.9% oxygen.
No gas flow through T-piece.Obstruction in tubing or T-piece, or gas source not properly connected/opened.Check tubing for kinks. Ensure T-piece is clear. Verify gas source connection and valve.

9. Spésifikasi

10. Garansi jeung Rojongan

Kanggo inpormasi garansi atanapi dukungan téknis, mangga tingal resmi produsén websitus atanapi ngahubungan departemén layanan palanggan maranéhna. Simpen resi pameseran anjeun salaku bukti pameseran.

Dokumén Patali - R217P42

Praview MaxO2+ Industrial Oxygen Analyzer: Instructions for Use
This document provides comprehensive instructions for the Maxtec MaxO2+ Industrial Oxygen Analyzer, covering its features, operation, calibration, maintenance, troubleshooting, specifications, and electromagnetic compatibility.
Praview Maxtec MAXO2 + AE Industrial Oksigén Analyzer: Manual Operasi jeung Parentah
Manual operasi komprehensif sarta parentah pikeun Maxtec MAXO2 + AE Industrial oksigén analyzer. Nyertakeun sistem leuwihview, operasi, calibration, pangropéa, spésifikasi, sarta ngungkulan.
Praview Maxtec MaxO2+ Oxygen Analyzer User Manual
Comprehensive user manual for the Maxtec MaxO2+ Oxygen Analyzer, detailing operation, calibration, maintenance, specifications, and troubleshooting for accurate oxygen measurement in medical settings.
Praview MaxO2+A Oksigén Analyzer: Fitur, Spésifikasi, jeung Asesoris
Panggihan MaxO2+A, analisa oksigén portabel sareng ramah-pamaké ti Maxtec. Diajar ngeunaan fitur konci, spésifikasi téknis, nomer bagian, sareng asesoris anu sayogi pikeun pangukuran oksigén anu akurat dina sababaraha aplikasi.
Praview Maxtec Handi + Industrial Oksigén Analyzer: parentah pikeun pamakéan
Parentah komprehensif pikeun analisa oksigén industri Maxtec Handi +, nyertakeun setelan, operasi, kalibrasi, kode kasalahan, pangropéa, sareng spésifikasi. Fitur sensor oksigén MAX-250 pikeun ngawaskeun akurat.
Praview MaxBlend 2 Low Flow / High Flow Oxygen Blender - Instructions for Use
This document provides comprehensive instructions for use, safety guidelines, specifications, and troubleshooting for the Maxtec MaxBlend 2 Low Flow / High Flow Oxygen Blender, a medical device for air/oxygen gas mixing and monitoring.