Siaga munggaran SCO500

First Alert Logo: Protecting Homes & Families Since 1958

First Alert SCO501CN-3ST Wireless Interconnected Combination Smoke and Carbon Monoxide Alarm User Manual

Model: SCO500

1. Bubuka

This manual provides essential information for the proper installation, operation, and maintenance of your First Alert SCO501CN-3ST Wireless Interconnected Combination Smoke and Carbon Monoxide Alarm. This device is designed to detect both smoke and carbon monoxide (CO) hazards, offering enhanced safety for your home. It features wireless interconnection capabilities, allowing multiple alarms to communicate and activate simultaneously throughout your residence.

2. Émbaran Kasalametan

Carbon monoxide is an invisible, odorless, and deadly gas that can be produced by any fuel-burning appliance. CO alarms detect this poisonous gas and provide early warning. For maximum protection, it is recommended to use both ionization and photoelectric sensing technologies. This alarm incorporates a photoelectric smoke sensor, designed to reduce false alarms from cooking smoke or shower steam, and an advanced electrochemical CO sensor.

What Is Carbon Monoxide? Carbon monoxide is an invisible, odorless, and deadly gas that can be produced by any fuel-burning appliance. CO alarms detect this poisonous gas and provide early warning.

Common Sources of Carbon Monoxide

Carbon monoxide can originate from various household appliances and systems. Be aware of potential sources such as:

  • Tungku
  • Vents dryer
  • hawu
  • Pamanas cai
  • Gas stoves and ovens
  • Hawu
  • Automobiles in attached garages
Text: Common Sources of Carbon MonoxideIcon of a furnaceIcon of a dryer ventIcon of a chimney

Disarankeun panempatan

Install smoke alarms on every level of your home and in every bedroom. Carbon monoxide alarms should also be placed on every level and in every bedroom. Avoid placing alarms in 'dead zones' where walls and ceilings meet, as smoke detectors are less effective in these areas.

Diagram showing recommended placement of smoke alarms, CO alarms, and fire extinguishers in a house, including bedrooms, hallway, living room, kitchen, basement, and garage.

3. Fitur Produk

  • Combination Detection: Detects both smoke and carbon monoxide.
  • Sambungan nirkabel: Connects with up to 18 other compatible First Alert alarms for a synchronized safety network.
  • Lokasi Sora: Announces the type of threat and its location (e.g., "Fire in the Kitchen!"). Features 11 programmable locations.
  • Sensor Haseup Fotolistrik: Designed to minimize false alarms from cooking or steam while effectively detecting smoldering fires.
  • Electrochemical CO Sensor: Provides accurate detection of carbon monoxide.
  • Batré Dioperasikeun: Easy installation without hardwiring.
  • Operasi Hiji Tombol: A single button for testing the unit and silencing false alarms.
  • Alarm nyaring: Emits an 85-decibel siren to alert occupants.
  • EZ Access Battery Drawer: Allows for easy battery replacement without removing the alarm from the ceiling.
First Alert SCO501CN-3ST Combination Smoke and Carbon Monoxide Alarm, front view.

Hareupeun view of the First Alert SCO501CN-3ST Combination Alarm.

4. Setélan

4.1. Pamasangan

The alarm is battery-operated for easy installation. Mount the alarm securely to the ceiling or wall in accordance with local codes and the recommended placement guidelines. Ensure the mounting plate is firmly attached before twisting the alarm onto it.

4.2. Pamasangan batré

Your alarm requires two (2) AA batteries (included). To install or replace batteries:

  1. Locate the EZ access battery drawer on the side of the alarm.
  2. Open the battery drawer.
  3. Pasangkeun dua batré AA, pastikeun polaritasna (+ sareng -) leres.
  4. Close the battery drawer until it clicks securely into place.

4.3. Interkoneksi Nirkabel

To create a wireless safety network, follow the pairing instructions provided in the full user manual to interconnect this alarm with other compatible First Alert alarms. This allows all interconnected alarms to sound when one detects a hazard.

Video: Product Summary - Demonstrates key features and ease of use for the First Alert Combination Alarm.

5. Nyuping

5.1. Nguji Alarm

Test your alarm weekly to ensure proper function. Press and hold the 'Test/Silence' button on the alarm until it sounds. The alarm will emit a loud 85-decibel sound and announce its status. If interconnected, all alarms should sound.

5.2. Silence Feature

In case of a nuisance alarm (e.g., from cooking smoke), press the 'Test/Silence' button to temporarily silence the alarm. The alarm will reset after a few minutes if the smoke or CO levels return to normal.

5.3. Sinyal Alarm

The alarm provides distinct audible and voice alerts for different conditions:

  • Alarm haseup: Three loud beeps followed by a voice announcement like "Fire! Fire!" and the location.
  • Alarm Karbon Monoksida: Four loud beeps followed by a voice announcement like "Warning! Carbon Monoxide!" and the location.
  • Perhatosan Batré Lemah: One chirp every minute.
  • Rusak: Three chirps every minute.
  • Ahir Kahirupan: Five chirps every minute.
Text: What does the beep mean?Icon for 4 beeps and a pause, indicating CO alarmIcon for 1 beep every minute, indicating low batteryIcon for 5 beeps every minute, indicating end of life

6. Pangropéa

6.1. beberesih

Gently vacuum or use clean compressed air to remove accumulated dust monthly. Never use water, cleaners, or solvents, as these can damage the unit. If the alarm becomes excessively dirty, it may need to be replaced.

6.2. Ngagantian batré

Replace the two (2) AA batteries once a year, or immediately when the low battery warning (one chirp per minute) sounds. Refer to section 4.2 for battery installation instructions.

7. Cara ngungkulan

If your alarm sounds, identify the type of alert based on the beeping pattern and voice announcement. Take appropriate action:

  • Smoke Alarm (3 beeps + voice): Immediately evacuate the premises and call emergency services (Fire Department or 911).
  • CO Alarm (4 beeps + voice): Immediately move to fresh air outdoors or by an open door/window. Call emergency services if symptoms persist.
  • Low Battery (1 chirp/minute): Ganti batré langsung.
  • Malfunction (3 chirps/minute): Replace the alarm unit.
  • End of Life (5 chirps/minute): Replace the alarm unit.

8. Spésifikasi

merekSiaga munggaran
Nomer modélSCO500
Sumber DayaDidukung ku batré (kaasup 2 batré AA)
Dimensi produk2 "D x 5" W x 5" H
Item Beurat3.2 ons
Jenis AlarmAudible (85 dB) with Voice Location
Tipe sénsorFotolistrik (Haseup), Éléktrokimia (CO)
InterkonéksiWireless, up to 18 compatible alarms
Samping view of the First Alert SCO501CN-3ST Combination Alarm, showing dimensions of 5 inches width and 2 inches depth.

Samping view with approximate dimensions.

9. Garansi jeung Rojongan

This First Alert alarm comes with a 7-year limited warranty. For warranty claims, technical support, or further assistance, please refer to the contact information provided in the original product packaging or visit the official First Alert websitus.

Dokumén Patali - SCO500

Praview Mimiti Waspada SMCO500V Haseup & Karbon Monoksida Alarm Manual Pamaké
Manual pamaké komprehensif pikeun Mimiti Siaga SMCO500V Haseup & Karbon Monoksida Alarm. Diajar ngeunaan pamasangan, fitur, uji, pangropéa, ngungkulan masalah, inpormasi kaamanan, sareng garansi.
Praview Mimiti Waspada Onelink Wi-Fi Haseup + Karbon Monoksida Alarm Pamaké Manual AC10-500
Manual pamaké komprehensif pikeun First Alert Onelink AC10-500 Wi-Fi Haseup + Karbon Monoksida Alarm, ngawengku pamasangan, operasi, pangropéa, ngungkulan, sarta informasi kaamanan. Diajar ngeunaan fitur alarm, panempatan, setelan, sareng prosedur darurat.
Praview Mimiti Siaga SC5 Wireless Smart Haseup & Karbon Monoksida Alarm (SMC0600NV) - Instalasi sareng Rujukan Manual
This document provides comprehensive installation, operation, and maintenance instructions for the First Alert SC5 Wireless Smart Smoke & Carbon Monoxide Alarm (Model SMC0600NV). It covers safety information, installation guidelines, testing procedures, and emergency response protocols.
Praview Mimiti Siaga SC5 Kabel Smart Haseup & Karbon Monoksida Alarm Instalasi sareng Rujukan Manual
Comprehensive installation and reference manual for the First Alert SC5 Wired Smart Smoke & Carbon Monoxide Alarm (Model SMC0600NV-AC). Covers safety information, installation procedures, maintenance, and response protocols for smoke and carbon monoxide detection.
Praview Mimiti Siaga ZCOMBO Kombinasi Haseup sareng Karbon Monoksida Alarm Manual
Manual pangguna anu lengkep pikeun Alarm Haseup sareng Karbon Monoksida Kombinasi ZCOMBO First Alert. Diajar ngeunaan pamasangan, pangropéa, uji coba, fitur kaamanan, ngungkulan masalah, sareng integrasi Z-Wave pikeun kaamanan bumi anu ditingkatkeun.
Praview Mimiti Waspada SMCO500V Haseup sareng Karbon Monoksida Alarm Manual
Manual pamaké komprehensif pikeun Mimiti Siaga SMCO500V batré-Powered Haseup & Karbon Monoksida Alarm. Pituduh ieu nyertakeun pamasangan, fitur, pangropéa, ngungkulan, sareng inpormasi kaamanan pikeun alarm interkonéksi nirkabel ieu sareng béwara sora sareng lokasi.