Intermatic HB300RCL

Intermatic HB300RCL Outdoor Mechanical Timer Instruction Manual

Model: HB300RCL

1. Bubuka

This manual provides detailed instructions for the safe and efficient operation of your Intermatic HB300RCL Outdoor Mechanical Timer. This device is designed to automate the ON/OFF cycles of outdoor electrical appliances, offering convenience and energy management. Please read this manual thoroughly before installation and use, and retain it for future reference.

2. Émbaran Kasalametan penting

PERHATOSAN: Pikeun ngirangan résiko kahuruan, sengatan listrik, atanapi tatu pribadi, salawasna turutan tindakan pencegahan kaamanan dasar ieu:

3. Eusi Paket

Your Intermatic HB300RCL package should contain the following item:

4. Fitur Produk

Intermatic HB300RCL Outdoor Mechanical Timer, showing the gray housing, clear protective cover, rotating dial with red and green trippers, ON/OFF switch, and attached power cord with a two-prong plug.

Gambar 1: Intermatic HB300RCL Outdoor Mechanical Timer. This image displays the timer's gray plastic housing, a transparent hinged cover for weather protection, the central mechanical dial with time markings, and the red and green trippers used for setting ON/OFF times. A white ON/OFF indicator switch is visible above the dial, and a black power cord with a standard two-prong plug extends from the bottom.

The Intermatic HB300RCL timer offers the following key features:

5. Setélan

5.1 Pasang Timer

The HB300RCL timer can be mounted to a wall or post using the keyhole slot located on the back of the unit. Ensure the mounting location is protected from direct heavy rain and is easily accessible for setting and adjustments. If temporary placement is desired, ensure the timer is on a stable, level surface.

5.2 Nyetél Waktos Ayeuna

  1. Locate the rotating dial on the front of the timer. The dial is marked with 24 hours, typically with AM/PM indicators.
  2. Rotate the entire dial clockwise until the current time aligns with the "TIME OF DAY" arrow indicator (usually a small triangle or line) located in the center of the dial.
  3. Ensure you correctly distinguish between AM and PM hours when setting the current time.

5.3 Nyambung kana Kakuatan

Plug the timer's integrated power cord into a standard 120V outdoor-rated, grounded electrical outlet. Ensure the outlet is protected by a Ground Fault Circuit Interrupter (GFCI) for outdoor use safety.

6. Parentah Operasi

6.1 Setting ON/OFF Times

The timer uses captured trippers to set the ON and OFF times. There are typically two sets of trippers: a green tripper for ON and a red tripper for OFF.

  1. Setel Waktu ON: Locate the green tripper. Push it inwards towards the center of the dial at the desired time you want the connected appliance to turn ON.
  2. Waktu Pareum: Locate the red tripper. Push it inwards towards the center of the dial at the desired time you want the connected appliance to turn OFF.
  3. You can set up to two ON/OFF cycles per 24-hour period. Ensure the ON tripper is set before the OFF tripper for each cycle.
  4. The dial will rotate continuously. When the current time reaches a set tripper, the timer will switch the power state.

6.2 Using the Manual ON/OFF Switch

A manual ON/OFF switch is located above the dial. This switch allows you to override the timer's program temporarily. Pushing the switch will toggle the power to the connected appliance without affecting the set program. The indicator light will show the current power status.

6.3 Connecting an Appliance

Plug the appliance you wish to control into the single receptacle on the bottom of the timer unit. Ensure the appliance's power requirements do not exceed the timer's 12 Amp, 1500 Watt capacity.

7. Pangropéa

8. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Timer teu hurung/pareum dina waktu anu tos disetel.
  • Waktos ayeuna teu disetel leres.
  • Trippers not engaged or set incorrectly.
  • Manual override switch is engaged.
  • Verify the current time is aligned with the "TIME OF DAY" indicator.
  • Ensure green (ON) and red (OFF) trippers are pushed inwards at the desired times.
  • Check the manual ON/OFF switch and ensure it is in the desired automatic position.
Appliance connected to timer is not receiving power.
  • Timer not plugged into a live outlet.
  • outlet GFCI tripped.
  • Appliance itself is faulty.
  • Timer is faulty.
  • Pariksa sumber listrikna.
  • Reset stop kontak GFCI.
  • Uji alatna ku cara nyolokkeun langsung kana stop kontak anu tiasa dianggo.
  • If all else fails, the timer may require replacement.
Protective cover does not stay closed.
  • No latching mechanism, relies on gravity or mounting position.
  • Ensure the timer is mounted upright. If not mounted, the cover may not stay closed. Consider securing with weather-resistant tape if necessary for temporary horizontal use, ensuring ventilation is not blocked.
Time markings on dial are difficult to read.
  • Low contrast printing, especially for nighttime hours.
  • Use in well-lit conditions. A flashlight may be helpful for setting times in low light.

9. Spésifikasi

Nomer modélHB300RCL
merekIntermatik
Voltage120 volt
Ampumur12 Amps
Wattage1500 Watt
Number of ON/OFF Settings2 per poé
Bahanpalastik
Warnakulawu
Item Beurat8 ons
UPC078275110861
Dimensi (Pakét)11.2 x 6.8 x 2.4 inci

10. Garansi jeung Rojongan

10.1 Émbaran jaminan

This Intermatic HB300RCL timer comes with a Kawates Jaminan Hirupna. For specific terms, conditions, and limitations of this warranty, please refer to the official Intermatic warranty documentation or visit the manufacturer's websitus.

10.2 Rojongan Palanggan

For technical assistance, troubleshooting beyond this manual, or warranty claims, please contact Intermatic customer support. You can typically find contact information on the official Intermatic websitus: www.intermatic.com.

Dokumén Patali - HB300RCL

Praview Pituduh Pamasangan sareng Pamrograman Saklar Timer Lampu Intermatic EJ341C/EJ343C
Pitunjuk lengkep pikeun masang sareng ngaprogram saklar timer lampu Intermatic EJ341C (Kutub Tunggal) sareng EJ343C (Tilu Arah). Ngawengku setelan, kontrol, metode pemrograman, ngungkulan masalah, sareng spésifikasi.
Praview Pituduh Pamasangan sareng Operasi Timer Hitung Mundur Éléktronik Intermatic EI200
Detailed guide for installing and operating the Intermatic EI200 electronic in-wall countdown timer. Features include 5-30 minute time ranges, continuous HOLD mode, and ratings for 15A general purpose, 1000W tungsten, and 1/4 HP motors. Includes warranty information.
Praview Timer Hitung Mundur Éléktronik Intermatic EI210 - Panduan Pamasangan & Operasi
Comprehensive guide for the Intermatic EI210 electronic in-wall countdown timer, detailing features, installation steps, operation modes (Timer and Hold), and warranty information. Includes technical specifications and contact details for Intermatic Incorporated.
Praview Kumaha Masang sareng Ngoperasikeun Timer In-Wall Intermatic E-1020 24 Jam
Pituduh lengkep pikeun masang sareng ngoperasikeun timer mékanis dina témbok Intermatic E-1020 24 jam sababaraha program. Ngawengku parentah kabel, léngkah-léngkah pamrograman, sareng inpormasi garansi.
Praview Intermatic T173 T170 Pindah Timer Mékanis - 24 Jam, 125V, 5HP
spésifikasi lengkep pikeun Intermatic T173 T170 Mechanical Timer Pindah. Fitur setelan 24-jam, 125 VAC, rating motor 5 HP, 2NO kontak DPST, jeung NEMA 1 dipager. Cocog jeung komérsial, industri, padumukan, outdoor, sarta aplikasi HVACR.
Praview Timer Seri Intermatic T100: Panduan Operasi sareng Setélan
Pituduh lengkep ngeunaan cara ngoperasikeun, nyetel, sareng ngungkulan masalah timer mékanis Intermatic seri T100, kalebet pitunjuk kaamanan, pedaran komponén, sareng sumber daya pikeun dukungan.