PILZ 750103

Pilz PNOZ s3 Safety Relay Instruction Manual

Model: 750103 | Brand: PILZ

1. Bubuka

The Pilz PNOZ s3 is a compact safety relay designed for monitoring safety functions in industrial applications. It is specifically engineered to monitor E-STOP pushbuttons, safety gates, and light grids, ensuring the safe operation of machinery by reliably detecting and reacting to hazardous conditions. This manual provides essential information for the proper installation, operation, and maintenance of the PNOZ s3 safety relay.

2. Émbaran Kasalametan

penting: Read and understand all safety instructions before installing, operating, or performing maintenance on the PNOZ s3 safety relay. Failure to comply with these instructions may result in serious injury or death, and/or damage to the equipment.

3. Produk Langkungview

The Pilz PNOZ s3 safety relay features a compact design with clearly labeled terminals and status indicators on the front panel. It is designed for plug-in mounting, allowing for easy installation and replacement.

Pilz PNOZ s3 Safety Relay front view with terminals and indicators

Gambar 1: Hareupeun view of the Pilz PNOZ s3 Safety Relay, showing input/output terminals and status indicators.

3.1. Terminal

The relay is equipped with screw terminals for secure electrical connections. Key terminals include:

3.2. Indikator

The front panel includes LED indicators to provide status information:

4. Setup jeung Instalasi

4.1. Pamasangan

The PNOZ s3 is designed for plug-in mounting onto a compatible base or DIN rail adapter. Ensure the mounting location is free from excessive vibration, moisture, and extreme temperatures. Allow adequate space for ventilation and wiring.

4.2. Kabel

All wiring must be performed according to the provided wiring diagrams from PILZ and relevant electrical standards. Use appropriate wire gauges and ensure all connections are secure to prevent loose contacts.

5. Parentah Operasi

Once properly installed and wired, the PNOZ s3 safety relay operates by monitoring the status of its input circuits. When all safety inputs are closed (e.g., E-STOP released, safety gate closed), and after a successful reset, the safety outputs will close, allowing the machine to operate. If any safety input opens, the outputs will immediately open, bringing the machine to a safe state.

5.1. Ngahurungkeun sareng Ngareset Mimiti

5.2. Operasi Normal

During normal operation, the 'Power', 'In1', 'In2', and 'Out' LEDs should be illuminated, indicating that the safety circuit is closed and the machine is enabled. If a safety function is activated (e.g., E-STOP pressed, safety gate opened), the corresponding input LED(s) will change state, and the 'Out' LED will turn off as the safety outputs open.

6. Pangropéa

The Pilz PNOZ s3 safety relay is designed for minimal maintenance. Regular inspections are recommended to ensure continued safe operation.

7. Cara ngungkulan

This section provides guidance for common issues encountered with the PNOZ s3 safety relay.

GejalaMungkin Cukang lantarananaSolusi
Fault indicator (LED) is on.Internal fault, wiring error, or short circuit in the safety circuit.Check wiring for shorts or open circuits. Verify power supply. If fault persists, contact PILZ support.
No power LED illumination.Teu aya catu daya, voltase salahtage, or faulty wiring to A1/A2.Verify 24VDC power supply. Check connections to A1 and A2.
Outputs not activating (Out LED off).Safety inputs not closed, reset not performed, or internal fault.Ensure all safety inputs are in their safe state. Perform a manual reset if required. Check input LEDs.
Inputs (In1, In2) LEDs not illuminating correctly.Faulty safety device, wiring issue to input terminals, or incorrect input configuration.Check the connected safety devices (E-STOP, safety gate). Verify wiring to S11, S12, S21, S22, S34.

8. Spésifikasi

Key technical specifications for the Pilz PNOZ s3 safety relay (Model: 750103):

9. Garansi jeung Rojongan

For detailed warranty information, please refer to the official PILZ warranty policy available on their website or contact your authorized PILZ distributor. In case of technical issues or questions not covered in this manual, please contact PILZ technical support for assistance. Ensure you have the model number (750103) and serial number of your device ready when contacting support.

PILZ Official Websitus: www.pilz.com

Dokumén Patali - 750103

Praview PNOZ 10 Kasalametan Relay Operasi Manual
Manual operasi ieu nyadiakeun informasi komprehensif ngeunaan fungsi, operasi, instalasi, sarta sambungan tina relay kaamanan Pilz PNOZ 10. Éta kalebet spésifikasi téknis anu lengkep, fitur kaamanan, diagram pengkabelan, sareng pituduh ngungkulan.
Praview Pilz PNOZ s3 Safety Relay Operating Manual
Comprehensive operating manual for the Pilz PNOZ s3 safety relay, covering installation, operation, technical details, and safety features for industrial automation applications.
Praview Pilz PNOZ s3 Safety Relay Operating Manual
This operating manual provides comprehensive details on the Pilz PNOZ s3 safety relay, covering its functions, installation, wiring, operation, and technical specifications for industrial safety applications.
Praview Relay Kasalametan Pilz PNOZ s3: Manual Operasi sareng Rincian Téknis
Manual operasi komprehensif sarta spésifikasi teknis pikeun relay kaamanan Pilz PNOZ s3, ngawengku fitur, instalasi, wiring, operasi, ngungkulan, sarta data teknis.
Praview PILZ PNOZ s3 Sicherheitsschaltgerät Technische Daten und Spezifikationen
Detaillierte technische Daten für das PILZ PNOZ s3 Sicherheitsschaltgerät, einschließlich elektrischer, mechanischer und Umweltdaten, Sicherheitskennzahlen, Lebensdauerkurven und Zulassungen.
Praview Pilz PNOZ X6 Kasalametan Relay Manual Operasi
Manual operasi komprehensif pikeun relay kaamanan Pilz PNOZ X6, ngawengku fungsi na, instalasi, wiring, operasi, sarta spésifikasi teknis. Ngawengku tungtunan kaamanan sarta informasi urutan.