This manual provides essential information for the safe and efficient operation of your VENTS Extractor TT 150. The TT 150 is a mixed-flow inline extractor fan designed for ventilation systems, offering two speed settings for flexible airflow control. It is suitable for various applications requiring efficient air extraction or intake, such as hydroponic grow tents.
Please read these instructions carefully before installation and use, and retain them for future reference.
2. Émbaran Kasalametan
Always observe the following safety precautions to prevent injury and damage to the unit:
- Pastikeun catu daya cocog sareng voltage anu ditangtukeun dina labél produk (230 Volt).
- Disconnect the power supply before performing any installation, maintenance, or cleaning.
- Pamasangan kedah dilakukeun ku tukang listrik anu mumpuni saluyu sareng kode listrik lokal.
- Entong ngoperasikeun kipas nganggo kabel listrik atanapi colokan anu ruksak.
- Jauhkeun leungeun sareng barang asing tina bilah kipas salami dioperasikeun.
- Ulah nganggo kipas dina lingkungan anu aya gas anu gampang ngabeledug atanapi kaduruk.
- Ensure proper ventilation around the fan to prevent overheating.
- Alat ieu henteu dimaksudkeun pikeun dianggo ku jalma (kalebet murangkalih) anu ngirangan kamampuan fisik, indrawi atanapi mental, atanapi kirang pangalaman sareng pangaweruh, kecuali aranjeunna dipasihan pangawasan atanapi petunjuk ngeunaan panggunaan alat ku jalma anu tanggung jawab kana kasalametanana.
3. Eusi Paket
Pastikeun yén sadaya komponén aya sareng henteu ruksak:
- 1 x VENTS Extractor TT 150 (405-520m3/h)
- Manual Pitunjuk (dokumén ieu)

Gambar 1: Utama view of the VENTS Extractor TT 150. This image shows the complete inline fan unit, highlighting its compact design and the VENTS branding.
4. Setup jeung Instalasi
The VENTS Extractor TT 150 is designed for inline mounting within ducting systems or wall mounting. Ensure the installation location is stable and can support the weight of the unit (approximately 3.1 kg).
4.1 Pamasangan
The fan can be mounted directly into a ventilation duct or secured to a wall using appropriate fasteners (not included). The unit features an adjustable height capability, which refers to the flexibility in positioning the fan within your ventilation setup.

Gambar 2: Sisi view of the VENTS Extractor TT 150, illustrating the mounting brackets and overall structure for installation within a ducting system.
4.2 Sambungan Listrik
Connect the fan to a 230 Volt electrical supply using a suitable cable. Ensure all connections are secure and insulated. The fan operates with a power consumption of 60 watts.
- Taroskeun ka tukang listrik anu mumpuni pikeun masang kabel upami anjeun teu yakin.
- Ensure the power is off at the main circuit breaker before making any electrical connections.
5. Parentah Operasi
The VENTS Extractor TT 150 features two speed settings to adjust the airflow according to your requirements. The fan is controlled via an external switch (not included) that allows selection between the two speeds.
5.1 Pamilihan Speed
Refer to the wiring diagram provided with your unit for connecting the speed selector switch. The two speeds correspond to different airflow rates, typically ranging from 405 m³/h to 520 m³/h.

Image 3: Performance curve for the VENTS Extractor TT 150. This graph illustrates the relationship between static pressure (ΔP in Pa) and airflow (m³/h) for both minimum (min) and maximum (max) speed settings, indicating the fan's operational range.
5.2 Arah Aliran Udara
Ensure the fan is installed with the correct airflow direction for your application. An arrow on the fan casing typically indicates the direction of airflow.
6. Pangropéa
Regular maintenance ensures optimal performance and extends the lifespan of your VENTS Extractor TT 150.
- beberesih: Periodically clean the fan blades and housing to remove dust and debris. Disconnect power before cleaning. Use a soft, damp lawon; ulah nganggo pembersih atanapi pelarut anu abrasif.
- Pamariksaan: Regularly inspect the fan for any signs of wear, damage, or loose connections.
- Lubrication: The fan motor is typically sealed and does not require lubrication. Do not attempt to lubricate internal components.
7. Cara ngungkulan
If you encounter issues with your VENTS Extractor TT 150, refer to the following common troubleshooting steps:
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Kipas teu ngamimitian | Taya catu daya Wiring lepat Kasalahan motor | Pariksa sambungan kakuatan sarta circuit breaker Pariksa sambungan kabel (konsultasi ka tukang listrik) Contact support if motor is faulty |
| Ngurangan aliran hawa | Blocked ducts Kotor bilah kipas Setélan laju salah | Inspect and clear ducts Clean fan blades (disconnect power first) Ensure correct speed is selected |
| Noise atawa geter kaleuleuwihan | Pamasangan leupas Uing dina kipas Sabeulah ruksak | Tighten ningkatna screws Clean fan of any foreign objects Inspect blades for damage; contact support if damaged |
If the problem persists after attempting these solutions, please contact VENTS customer support or your retailer.
8. Spésifikasi
| Fitur | Spésifikasi |
|---|---|
| merek | KULIAH |
| Nomer modél | TT 150 |
| ID produsén | 5077 |
| Ukuran (L x W x H) | 31.4 x 30 x 24.8 cm |
| Beurat | 3.1 kg |
| Sumber Daya | Kabel Listrik |
| Voltage | 230 volt |
| Konsumsi Daya | 60 Watt |
| Laju Aliran Udara | 405-520 m³/h (2 speeds) |
| Tingkat Sora | 44 desibel |
| Kelas Efisiensi | A |
| European Energy Efficiency Class | A+ nepi ka G |
| Setélan speed | 2 RPM (interpreted as 2 speed settings) |
| Fitur husus | Adjustable height (for mounting flexibility) |
| Bahan | palastik |
| Métode Pamasangan | Wall Mount, Inline Mount |
9. Garansi jeung Rojongan
For warranty information, please refer to the terms and conditions provided by your retailer or contact VENTS customer service directly. Keep your proof of purchase for any warranty claims.