1. Bubuka
Thank you for choosing the Maxair C7180V1-MS-MAP 80-Gallon Electric Stationary Vertical Air Compressor. This manual provides essential information for the safe and efficient operation, installation, and maintenance of your new air compressor. Please read this manual thoroughly before operating the unit and retain it for future reference.
This high-performance cast iron air compressor is designed for demanding tasks such as painting furniture, grinding welds, and heavy-duty nailing. Its vertical tank design optimizes floor space, making it suitable for various workshop environments.

Figure 1: Maxair C7180V1-MS-MAP Air Compressor
2. Émbaran Kasalametan
Salawasna merhatikeun precautions kaamanan dasar pikeun ngurangan résiko seuneu, shock listrik, sarta tatu pribadi. Paranti nuturkeun parentah ieu bisa ngakibatkeun tatu serius atawa karuksakan harta.
Peringatan Kasalametan Umum:
- Kasalametan listrik: Ensure the compressor is connected to a properly grounded 230V, 1-phase power supply. Do not operate with damaged cords or plugs.
- Kaamanan tekanan: Never exceed the maximum operating pressure of 170 PSI. Always wear appropriate eye protection when operating the compressor or using air tools.
- Bagian Pindah: Keep hands, feet, and clothing away from moving parts, such as the belt and fan, especially when the compressor is running. The sturdy metal belt guard must always be in place during operation.
- Ventilasi: Operate the compressor in a well-ventilated area to prevent overheating and ensure proper air intake.
- Pangropéa: Disconnect power before performing any maintenance or service. Relieve all air pressure from the tank before servicing.
3. Setup jeung Instalasi
3.1 Ngabongkar sareng Inspeksi
Carefully remove the compressor from its packaging. Inspect the unit for any shipping damage. Report any damage immediately to your supplier.
3.2 Nempatkeun
Position the compressor on a firm, level surface. The 80-gallon vertical tank design is space-saving, but ensure adequate clearance around the unit for ventilation and maintenance access. Avoid placing the compressor near heat sources or in direct sunlight.
3.3 Sambungan Listrik
This compressor requires a 230V, 1-phase electrical supply. Ensure the circuit is properly sized and protected by a suitable circuit breaker. The unit is equipped with a magnetic starter for easy and safe operation, and to extend motor life.
3.4 Initial Oil Check
Before first use, verify the oil level using the easy-view oil site gauge. Add compressor oil if necessary, ensuring the level is within the recommended range.
4. Parentah Operasi
4.1 Ngamimitian Compressor
- Ensure all connections are secure and the power cord is properly plugged in.
- Turn on the main power switch, typically located on the magnetic starter control box.
- The heavy-duty pressure switch will automatically start the motor when the tank pressure drops below a preset level and stop it when the maximum pressure is reached.
4.2 Using Air Tools
Connect your air tools to the compressor's air outlet. Adjust the regulator to the desired working pressure for your specific application. The compressor delivers 30 CFM at 100 PSI, suitable for various high-performance tasks.
4.3 Pareuman
- Pareuman saklar kakuatan utama.
- Bleed any remaining air pressure from the tank using the drain valve or by operating an air tool until the pressure gauge reads zero.
5. Pangropéa
Regular maintenance ensures the longevity and optimal performance of your Maxair compressor. Always disconnect power before performing any maintenance.
5.1 Pangropéa poean
- Solokan kondensat: Open the oil drain on the front of the unit to drain any accumulated moisture from the air tank. This prevents rust and extends tank life.
- Pariksa Level Oli: Verify the oil level using the easy-view oil site gauge. Maintain the oil level within the recommended range.
5.2 Pangropéa Mingguan / Bulanan
- Inspect Air Filters: Check the premium air intake filters for dirt and debris. Clean or replace as necessary to ensure efficient operation and prevent damage to the pump.
- Pariksa Tegangan Sabuk: Ensure the drive belt is properly tensioned. Adjust if too loose or too tight.
- Inspect Belt Guard: Verify the sturdy metal belt guard is securely in place and undamaged.

Figure 2: Key features and specifications of the Maxair C7180V1-MS-MAP
6. Cara ngungkulan
Bagian ieu nyayogikeun solusi pikeun masalah umum anu anjeun tiasa pendak sareng kompresor hawa anjeun. Pikeun masalah anu teu didaptarkeun di dieu, hubungi dukungan palanggan.
Masalah umum:
- Kompresor Teu Bisa Dihirupkeun: Check power supply, circuit breaker, and ensure the magnetic starter is engaged. Verify the pressure switch is functioning correctly.
- Low Air Pressure/Slow Recovery: Inspect air filters for clogging. Check for air leaks in hoses and connections. Ensure proper belt tension.
- Noise/Geter kaleuleuwihan: Check for loose components. Ensure the compressor is on a level surface. Inspect the belt and motor for issues.
- Minyak bocor: Inspect seals and connections around the oil drain and pump. Ensure the oil site gauge is not damaged.
7. Spésifikasi
Detailed technical specifications for the Maxair C7180V1-MS-MAP Air Compressor.
| Fitur | Spésifikasi |
|---|---|
| Modél | C7180V1MSMAP |
| merek | Maxair |
| Kapasitas tank | 80 Gallons (Vertical) |
| Tekanan Operasi Maksimum | 170 PSI |
| CFM @ 100 PSI | 30 CFM |
| Daya Motor | 7.5 hp |
| Voltage | 230 volt, 1 fase |
| Sumber Daya | Digerakkeun ku listrik |
| Fitur husus | Heavy Duty, Magnetic Starter, Easy View Oil Site Gauge, Sturdy Metal Belt Guard, Efficient Heat Removal |
| Dianjurkeun Mangpaat | Painting furniture, grinding welds, heavy duty nailing |
| Item Beurat | 490 pon |
| Ukuran (L x W x H) | 36 x 23.5 x 68 inci |
| Komponén Kaasup | Komprési hawa |

Figure 3: Dimensions of the Maxair C7180V1-MS-MAP Air Compressor

Gambar 4: Leuwihview of Maxair Premium features and specifications
8. Garansi jeung Rojongan
8.1 Émbaran jaminan
The Maxair C7180V1-MS-MAP Air Compressor comes with a Kawates 2-Taun Garansi. This warranty covers defects in materials and workmanship under normal use. Please refer to the warranty card included with your purchase for full terms and conditions.
8.2 Rojongan Palanggan
For technical assistance, parts, or warranty claims, please contact Maxair customer support. Have your model number (C7180V1MSMAP) and purchase date ready when contacting support.