Extech FL700

Buku Panduan Pangguna Alat Ukur Fluorida Extech FL700

Modél: FL700

1. Bubuka

The Extech FL700 Fluoride Meter is a precision instrument designed for the rapid and accurate measurement of fluoride ions in various aqueous samples, including drinking water. This device integrates a sensing electrode, measurement electronics, and a digital display into a single, portable unit, making it suitable for both field and laboratory applications.

The FL700 provides direct readings of total fluoride concentrations ranging from 9.99 ppm or mg/L down to 0.1 ppm. It features automatic temperature compensation to ensure measurement accuracy across varying environmental conditions.

2. Émbaran Kasalametan

Please read and understand all safety precautions before operating the Extech FL700 Fluoride Meter. Failure to follow these instructions may result in injury or damage to the instrument.

  • Always handle the fluoride electrode with care. Avoid touching the sensing element directly.
  • When working with TISAB reagent tablets or any chemical solutions, wear appropriate personal protective equipment, including gloves and eye protection.
  • Do not immerse the entire meter in liquid. The meter is designed for electrode immersion only.
  • Store the meter and reagents in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Jauhkeun tina jangkauan barudak.

3. Produk Langkungview

The Extech FL700 Fluoride Meter is a compact and user-friendly device. Key components and features are outlined below:

Extech FL700 Fluoride Meter front view
Hareupeun view of the Extech FL700 Fluoride Meter, showing the display and control buttons.
Hand holding Extech FL700 Fluoride Meter
The Extech FL700 Fluoride Meter held in hand, demonstrating its ergonomic design and clear display.
Close-up of Extech FL700 electrode tip
Pahareup-hareup view of the fluoride electrode tip, which is integrated into the meter.
Extech FL700 Fluoride Meter in use with sample
The Extech FL700 Fluoride Meter being used to measure a liquid sample, showing the meter in its stand.
Extech FL700 Fluoride Meter and included accessories
All components included with the Extech FL700: the meter, sensor cap, TISAB reagent tablets, and neckstrap.

Fitur konci:

  • Kalibrasi dua titik: Ensures accurate measurements across the fluoride range.
  • Panyimpen mémori: Stores up to 25 labeled readings for later review.
  • Field or lab testing: Designed for versatile use in various environments.
  • Fast response: Provides fluoride measurements in less than 1 minute.
  • Large dual LCD: Simultaneously displays ppm (or mg/L) and temperature with a bargraph.

4. Setélan

4.1. Pamasangan batré

The Extech FL700 requires four 3V button batteries (included). To install or replace batteries:

  1. Twist off the battery compartment cap located at the top of the meter.
  2. Insert the four 3V button batteries, ensuring correct polarity as indicated inside the compartment.
  3. Replace the battery compartment cap and twist to secure.

4.2. Persiapan Awal

Before first use or after prolonged storage, prepare the electrode:

  1. Remove the sensor cap from the electrode tip.
  2. Rinse the electrode tip with distilled water.
  3. Condition the electrode by immersing it in a fluoride standard solution (e.g., 1 ppm or 10 ppm) for approximately 15-30 minutes.

5. Parentah Operasi

5.1. Powering on / Pareum

Pencét éta ON/OFF tombol pikeun ngaktipkeun atanapi mareuman méter.

5.2. Calibration (Two-Point)

Accurate calibration is crucial for reliable measurements. The FL700 supports two-point calibration.

  1. Prepare two fluoride standard solutions, typically one low concentration (e.g., 1 ppm) and one high concentration (e.g., 10 ppm). Ensure the solutions are at a stable temperature.
  2. Bilas éléktroda ku cai sulingan jeung blot garing.
  3. Immerse the electrode into the first standard solution.
  4. Pencét jeung tahan tombol CAL / NGARETAK button until 'CAL' appears on the display. The meter will automatically recognize the standard and calibrate. Wait for the reading to stabilize.
  5. Rinse the electrode again and immerse it into the second standard solution.
  6. Pencét jeung tahan tombol CAL / NGARETAK button again. The meter will complete the two-point calibration.
  7. The meter is now calibrated and ready for measurement.

5.3. Nyandak Pangukuran

To measure fluoride concentration in a sample:

  1. Ensure the meter is calibrated.
  2. Bilas éléktroda ku cai sulingan jeung blot garing.
  3. Add TISAB (Total Ionic Strength Adjustment Buffer) reagent to your sample according to the reagent instructions. TISAB ensures that the fluoride ions are in a measurable form and minimizes interference.
  4. Immerse the electrode tip into the prepared sample solution. Ensure the tip is fully submerged.
  5. Allow the reading to stabilize on the display. The large dual LCD will show the fluoride concentration in ppm (or mg/L) and the temperature.
  6. To hold the current reading, press the MODE / NGANGGO tombol. Pencét deui pikeun ngaleupaskeun.

5.4. Recalling Stored Readings

The meter can store up to 25 labeled readings.

  • To recall stored readings, press the CAL / NGARETAK button briefly when not in calibration mode.
  • Ngagunakeun éta MODE / NGANGGO button to scroll through the stored readings.

6. Pangropéa

6.1. éléktroda beberesih

Regular cleaning of the electrode ensures optimal performance.

  • After each use, rinse the electrode thoroughly with distilled water.
  • If the electrode becomes fouled or readings become erratic, clean it with a mild detergent solution or a specialized electrode cleaning solution. Rinse thoroughly with distilled water afterward.

6.2. Panyimpenan

Proper storage extends the life of the electrode and meter.

  • Always replace the sensor cap on the electrode tip when not in use. The cap should contain a small amount of electrode storage solution or a fluoride standard solution to keep the membrane hydrated. Do not store dry.
  • Simpen méter dina tempat anu tiis sareng garing.

6.3. Ngagantian batré

Replace batteries when the low battery indicator appears on the display or when the meter fails to power on. Refer to Section 4.1 for battery installation instructions.

7. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Méter teu hurungBatré paéh atawa salah dipasangPariksa polaritasna batré; ngaganti accu.
Bacaan anu teu menentu atanapi teu stabilDirty electrode; air bubbles on electrode; insufficient sample volume; expired or incorrect TISAB.Clean electrode; gently tap electrode to remove bubbles; ensure electrode is fully submerged; check TISAB.
Meter fails to calibrateIncorrect standard solutions; dirty electrode; electrode not conditioned; damaged electrode.Verify standard concentrations; clean and condition electrode; replace electrode if damaged.
Indikator batré lemahBatré lemah.Replace all four 3V button batteries.

8. Spésifikasi

SpésifikasiRincian
ProdusénExtech
Nomer BagianFL700
Item Beurat7.7 ons
Dimensi produk6.8 x 1.6 x 1.4 inci
Nomer Modél ItemFL700
Batré4 batré Litium Metal diperlukeun (kaasup)
GayaFL700
Item Paket Kuantitas1
Jumlah Potongan1
Komponén KaasupUnit, Pituduh Instruksi
Tipe sél batréAlkali
Tanggal Sadia munggaran15 Juli 2008

9. Émbaran jaminan

The Extech FL700 Fluoride Meter comes with a full one-year warranty on parts and workmanship, unless otherwise specified. This warranty does not cover defects resulting from user actions such as misuse, improper wiring, operation outside of specified parameters, improper maintenance or repair, or unauthorized modification.

10. Rojongan

For technical support, service, or additional information, please visit the official Extech websitus atanapi ngahubungan departemén layanan palanggan maranéhna. Anjeun oge bisa manggihan inpo leuwih lengkep jeung produk di Toko Extech di Amazon.

Dokumén Patali - FL700

Praview EXTECH 45170 4-in-1 Kalembaban, Suhu, Aliran Udara, sareng Manual Pamaké Méter Cahaya
Manual pamaké pikeun EXTECH 45170, méteran 4-in-1 pikeun ngukur kalembaban, suhu, aliran hawa, sareng cahaya. Ngawengku operasi, spésifikasi, sareng inpormasi garansi.
Praview Manuale Utente Misuratore di Radiazione UV-AB Extech UV505
Manuale utente completo per il Misuratore di Radiazione UV-AB Extech UV505. Kaasup operasi instrumén, téknik husus, informasi di kaamanan jeung manual.
Praview Extech UV505 UV-AB Light Méter Manual Pamaké
Manual pamaké pikeun Extech UV505 UV-AB Light Méter. Dokumén ieu nyayogikeun inpormasi lengkep ngeunaan fitur alat, operasi, spésifikasi, pancegahan kaamanan, sareng pangropéa pikeun ngukur sinar UVA sareng UVB.
Praview Extech EX810 1000 Amp Klemmeter patepung IR Thermometer Gebruikershandleiding
Gedetailleerde gebruikershandleiding voor de Extech EX810 1000 Amp klemmeter patepung ingebouwde IR thermometer. Bevat instructies, veiligheidsrichtlijnen en technische specificaties voor nauwkeurige metingen van spanning, stroom, weerstand, capaciteit, frequentie en temperatuur.
Praview Extech MO257 Pinless Moisture Meter User Guide
User guide for the Extech MO257 Pinless Moisture Meter, detailing its features, operation, specifications, and maintenance for accurate non-invasive moisture measurements in building materials.
Praview Pituduh Pangguna Seri Extech EX650: 600A True RMS Digital Clamp Méter
Pituduh pangguna anu lengkep pikeun Extech EX650 Series tina 600A True RMS digital clamp méter, ngawengku modél EX650 sareng EX655. Diajar ngeunaan operasi, fitur, kaamanan, sareng spésifikasi pikeun voltase AC/DC anu akurattage, arus, résistansi, sareng pangukuran anu sanésna.