Red Lion 97101001

Buku Panduan Pangguna Pompa Sprinkler Red Lion RL-SPRK100

Modél: 97101001

1. Produk Langkungview

The Red Lion RL-SPRK100 is a 1 HP sprinkler pump designed for residential and light commercial lawn and turf sprinkling systems. It features a rugged cast iron casing and a high-efficiency thermoplastic impeller and diffuser. This pump is engineered for reliable performance and ease of use.

Red Lion RL-SPRK100 Sprinkler Pump

Image 1.1: The Red Lion RL-SPRK100 Sprinkler Pump, showcasing its red cast iron housing.

Fitur konci:

  • Konstruksi awét: Features a rugged cast iron pump housing and a glass-filled thermoplastic impeller, suitable for various water sources including well water and lake water.
  • Ganda Voltage Motor: Operates on either 115 Volts or 230 Volts. The pump is factory-set to 230 Volts but can be easily reconfigured to 115 Volts. It is crucial to match the pump's voltage setting to the power source voltage pikeun operasi ditangtoskeun.
  • Kamampuhan Self-Priming: Requires only a one-time initial prime. No additional priming is necessary after the initial fill, simplifying setup.
  • Kinerja luhur: Delivers up to 63 Gallons Per Minute (GPM) at 10 PSI and 38 GPM at 30 PSI. Capable of supporting up to 12 sprinkler heads with 1/2-inch fittings or 6 sprinkler heads with 3/4-inch fittings per zone.
  • Sambungan standar: Equipped with a 2-inch Female NPT threaded intake and a 1.5-inch Female NPT threaded discharge.
Red Lion RL-SPRK100 Sprinkler Pump Features

Image 1.2: Diagram highlighting key features of the pump, including the 2-inch FNPT intake, 1-1/2-inch FNPT discharge, cast iron casing, capacitor start, and thermally protected motor.

2. Setup jeung Instalasi

Proper installation is essential for the safe and efficient operation of your Red Lion RL-SPRK100 Sprinkler Pump. Refer to the complete installation manual included with your pump for detailed instructions and safety warnings.

2.1 Jilidtage Konfigurasi

The pump motor is factory-set to 230 Volts. If your power supply is 115 Volts, you must adjust the motor's voltage setting before operation. Failure to match the pump's voltage to the source voltage will prevent the pump from performing to specifications and may cause damage.

Red Lion RL-SPRK100 Dual Voltage Motor Setting

Image 2.1: Instructions for setting the dual voltage motor. The pump is factory preset to 230V. To switch to 115V, insert a flat screwdriver into the black voltage change indicator and twist counter-clockwise.

2.2 Priming Pompa

The RL-SPRK100 is a self-priming pump, meaning it only requires an initial prime. After the initial fill, no additional priming is typically required. Follow these general steps for initial priming:

  1. Pastikeun sadaya sambungan pipa aman sareng bebas bocor.
  2. Cabut colokan priming (biasana aya di luhureun pompa casing).
  3. Ngeusian pompa casing pinuh ku cai nepi ka ngalembur.
  4. Pasang deui sareng kencengkeun colokan priming.
  5. Open any discharge valves to allow air to escape the system.
  6. Start the pump. It should begin pumping water within a few minutes. If not, turn off the pump, re-prime, and check for air leaks in the suction line.
Red Lion RL-SPRK100 Self-Priming Feature

Image 2.2: The Red Lion Sprinkler Pump positioned in a lawn setting, illustrating its self-priming capability up to 25 feet after the initial prime.

3. Parentah Operasi

Once properly installed and primed, the Red Lion RL-SPRK100 Sprinkler Pump is ready for operation. Ensure all connections are tight and there are no obstructions in the intake or discharge lines.

3.1 Mimitian Pompa

Activate the power supply to the pump. The pump will begin to draw water and build pressure. Monitor the system for any unusual noises or leaks during initial startup.

Red Lion RL-SPRK100 Sprinkler Pump in operation

Image 3.1: The Red Lion Sprinkler Pump operating in a residential setting, drawing water from a well, lake, pond, or ditch for irrigation.

3.2 Performance Guidelines

The pump is designed to deliver consistent water flow and pressure for various sprinkler system configurations. Refer to the performance chart below for expected output based on dynamic head and flow rate.

Red Lion Sprinkler Pump Performance Chart

Image 3.2: Performance curve chart for Red Lion Centrifugal Sprinkler Pumps, including the RL-SPRK100, showing Total Dynamic Head (ft) versus Capacity (US gpm).

3.3 Pareuman Pompa

To turn off the pump, deactivate the power supply. If the pump will be inactive for an extended period or during freezing temperatures, follow the maintenance guidelines for winterization.

4. Pangropéa

Regular maintenance ensures the longevity and optimal performance of your Red Lion RL-SPRK100 Sprinkler Pump.

4.1 Cék rutin

  • Inspect the pump and plumbing for leaks, especially at connections.
  • Check for unusual noises or vibrations during operation, which may indicate a problem.
  • Ensure the pump's ventilation openings are clear of debris to prevent overheating.

4.2 Winterization

In regions subject to freezing temperatures, it is crucial to properly winterize the pump to prevent damage:

  1. Pegatkeun sambungan listrik kana pompa.
  2. Solokan sadaya cai tina pompa casing ku cara nyabut sumbat solokan.
  3. Disconnect the intake and discharge pipes and drain them thoroughly.
  4. Store the pump in a dry, frost-free location if possible. If not, ensure all water is completely removed and consider using RV antifreeze in the pump casing if recommended by a professional.

5. Cara ngungkulan

This section provides general guidance for common issues. For complex problems, consult a qualified technician or contact Red Lion customer support.

5.1 Pump Does Not Start

  • Henteu aya kakuatan: Check circuit breaker or fuse. Ensure power cord is securely plugged in.
  • Teu leres Voltage Setélan: Verify the pump's voltage setting matches the power supply (115V or 230V).
  • Motor Kaleuwihan Beban: Allow the motor to cool down if the thermal overload protector has tripped. Check for obstructions in the impeller.

5.2 Pump Runs But Delivers No Water or Low Pressure

  • Kaleungitan Perdana: Re-prime the pump as described in Section 2.2. Check for air leaks in the suction line or loose connections.
  • Clogged Intake/Impeller: Inspect the intake screen and impeller for debris.
  • Low Water Source: Ensure the water source level is adequate for the pump's suction lift capabilities.
  • Discharge Obstruction: Check for closed valves or blockages in the discharge piping or sprinkler heads.

5.3 Sora atanapi Geteran Anu Kaleuleuwihi

  • Hawa dina Sistem: Ensure the pump is fully primed and there are no air leaks.
  • Pasang Leupas: Check that the pump is securely mounted to a stable surface.
  • Foreign Object: Turn off power and inspect the impeller for any foreign objects.

6. Spésifikasi

Detailed technical specifications for the Red Lion RL-SPRK100 Sprinkler Pump.

Red Lion RL-SPRK100 Sprinkler Pump Dimensions

Image 6.1: Technical drawing illustrating the dimensions of the SPRK Series Sprinkler Pumps, including height (A), length (B), and width (C).

SpésifikasiNilai
merekRed Lion
Nomer modél97101001
Daya kuda1 hp
Voltage115/230 volt
Wattage4848 watt
Laju aliran maksimum63 Galon Per Menit (GPM)
Tekanan Maksimum45 PSI
Maksimum Ngangkat Jangkungna25 suku
Intake Thread Size2-inch Female NPT
Discharge Thread Size1.5-inch Female NPT
BahanCast Iron, Thermoplastic
Ukuran produk (L x W x H)21.85" x 11.42" x 10.2"
Item Beurat53 pon
Sumber DayaKabel Listrik
Komponén KaasupPump with thermoplastic impeller
UPC010121124868, 010121001398

7. Garansi jeung Rojongan

7.1 Garansi Produsén

The Red Lion RL-SPRK100 Sprinkler Pump is covered by a 2-taun jaminan produsén urang. Please retain your proof of purchase for warranty claims. For specific terms and conditions, refer to the warranty information provided with your product packaging.

7.2 Rojongan Téknis

For technical assistance, troubleshooting guidance, or questions regarding your Red Lion product, please contact our support team:

  • Telepon Rojongan Téknis: 1-888-885-9254

Our staff are available to assist with troubleshooting or installation assistance.

Dokumén Patali - 97101001

Praview Red Lion RL-SPRK Series Sprinkler Pump Owner's Manual - Installation, Operation, Maintenance Guide
This manual provides comprehensive instructions for the Red Lion RL-SPRK Series Sprinkler Pumps, covering installation, voltage settings, operation, maintenance, troubleshooting, and replacement parts. Designed for residential and commercial lawn and turf sprinkler systems.
Praview Pituduh Ngatasi Masalah Pompa Red Lion: Solusi pikeun Pompa Jet, Submersible, sareng Transfer
Comprehensive troubleshooting guide for Red Lion water pumps, including Shallow Well Jet Pumps (e.g., RJS-50-PREM), Convertible Jet Pumps (e.g., RJC-50), 4" Submersible Well Pumps (e.g., RL12G10-3W2V), Submersible Utility & Sump Pumps, RL-S Cast Iron Surface Effluent Pumps, RL-50 Transfer Pumps, and RLSP/RLHE Sprinkler Pumps. Find solutions for common issues like motor failure, priming problems, low pressure, and more.
Praview Red Lion RLHE-300 Cast Iron Industrial Sprinkler Pump Owner's Manual
Comprehensive owner's manual for the Red Lion RLHE-300 industrial sprinkler pump, covering installation, operation, maintenance, and troubleshooting. Features include heavy-duty iron casing, high-efficiency impeller, and automatic thermal protector.
Praview Red Lion CUB5 Miniatur Elektronik 8-Digit Penghitung Ganda sareng Indikator Laju
Detailed specifications, installation guide, and programming manual for the Red Lion CUB5 miniature electronic 8-digit dual counter and rate indicator. Features include selectable LCD or LED backlighting, optional relay and serial communication modules, and NEMA 4X/IP65 sealing.
Praview Red Lion RJSE-75SS Sprinkler Utility Pump - Operation and Maintenance Manual
Comprehensive guide for the Red Lion RJSE-75SS Sprinkler Utility Pump, covering safety warnings, electrical precautions, application, installation, operation, maintenance, and troubleshooting. Includes detailed diagrams and warranty information.
Praview Buku Panduan sareng Spésifikasi Pompa Utilitas Red Lion RL-MP25A
Buku panduan lengkep pikeun Pompa Utilitas Red Lion RL-MP25A, anu ngajelaskeun spésifikasi, pitunjuk kaamanan, pamasangan, operasi, pangropéa, sareng ngungkulan masalah. Ngawengku bagan laju aliran sareng data téknis.