1. Bubuka
The GIMA OXY 6 Finger Pulse Oximeter is a portable device designed for non-invasive spot-checking of arterial oxygen saturation (SpO2) and pulse rate. It is suitable for use in medical and hospital environments, as well as for personal use under medical guidance. This manual provides essential information for the safe and effective operation of the device.
2. Émbaran Kasalametan
Please read all safety warnings and precautions before using the device. Failure to do so may result in inaccurate readings or device malfunction.
- This device is intended for spot-checking and not for continuous monitoring.
- Entong nganggo oximeter dina lingkungan MRI atanapi CT.
- Jauhkeun alat tina cai sareng Uap.
- Consult a medical professional for interpretation of readings. This device is not a substitute for professional medical advice.
- Ensure the finger is clean and free of nail polish or artificial nails, as these can affect accuracy.
- Ulah aya gerakan anu kaleuleuwihi nalika ngukur pikeun mastikeun bacaan anu stabil.
3. Produk Langkungview
The GIMA OXY 6 features a high-resolution OLED color display showing SpO2, pulse rate, pulse bar graph, perfusion index (PI), and battery level. It is designed for ease of use with a compact form factor.

Gambar 1: Hareupeun view of the GIMA OXY 6 Pulse Oximeter, displaying SpO2 and pulse rate values on its screen.
3.1. Eusi Paket

Gambar 2: The package includes the GIMA OXY 6 Pulse Oximeter, a plastic case, AAA batteries, and a lanyard.
- GIMA OXY 6 Pulse Oximeter
- 2 x Batré AAA
- Palastik Mawa Case
- Lanyard
- Instruksi Manual

Gambar 3: The GIMA OXY 6 Pulse Oximeter attached to a lanyard, demonstrating its portability and ease of carrying.
4. Setélan
4.1. Pamasangan batré
- Buka panutup kompartemen batré anu aya di tukangeun alat.
- Insert two AAA batteries according to the polarity indicators (+/-) inside the compartment.
- Tutup panutup kompartemen batré aman.

Gambar 4: Open battery compartment showing placement for two AAA batteries.
5. Parentah Operasi
5.1. Nyandak Pangukuran
- Ensure the device has fresh batteries installed.
- Buka clamp tina oksiméter.
- Insert one finger (preferably the index, middle, or ring finger) into the rubber opening of the oximeter, ensuring the finger is fully inserted and resting on the sensor. The recommended finger thickness for this model is 1-22 mm.
- Ngaleupaskeun clamp. The device will automatically turn on and begin measurement.
- Keep your hand still during the measurement. Avoid bending your finger or making hand movements.
- Readings for SpO2, Pulse Rate, and Perfusion Index (PI) will appear on the display within a few seconds.

Gambar 5: The GIMA OXY 6 Pulse Oximeter correctly placed on a finger for measurement.
5.2. Ngartos Tampilan
- SpO2: Peripheral Oxygen Saturation, displayed as a percentage.
- PR: Pulse Rate, displayed in beats per minute (bpm).
- PI: Perfusion Index, a numerical value indicating the strength of the pulse signal at the sensor site.
- Pulse Bar Graph: Visual representation of pulse strength.
- Indikator batré: Nembongkeun tingkat batre ayeuna.
5.3. Otomatis Power Pareum
The device will automatically power off after approximately 8 seconds of inactivity or when the finger is removed.
5.4. Lemah Voltage Alarem
Nalika batréna voltage is low, a low voltage alarm will be indicated on the display. Replace the batteries promptly to ensure accurate operation.
5.5. Panungtun sora
The GIMA OXY 6 features an 8-language voice guide (English, French, Italian, Spanish, Greek, Portuguese, Arabic) for enhanced usability. Refer to the full manual for specific instructions on activating and changing voice guide settings.
6. Pangropéa
6.1. beberesih
- Bersihkeun permukaan oksimeter nganggo lawon lemesampened with medical alcohol (70% ethanol or isopropanol).
- Ulah ngalelepkeun alat kana cai atanapi larutan pembersih naon waé.
- Ensure the device is completely dry before reuse.
6.2. Ngagantian batré
Ngaganti accu lamun vol lowtage indicator appears. Always use two new AAA alkaline batteries. Dispose of used batteries according to local regulations.
6.3. Panyimpenan
Store the oximeter in its plastic carrying case in a cool, dry place, away from direct sunlight and extreme temperatures. Remove batteries if the device will not be used for an extended period.
7. Cara ngungkulan
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Henteu aya tampilan saatos hurung | Batré pareum atawa salah dipasang. | Ganti batréna atanapi pasang deui kalayan leres, bari tetep merhatikeun polaritasna. |
| Bacaan teu akurat | Finger not properly inserted; excessive movement; nail polish; cold finger. | Re-insert finger correctly; remain still; remove nail polish; warm the finger. |
| "Finger Out" or similar error message | Ramo teu kadeteksi atanapi dipasangna teu leres. | Ensure finger is fully inserted and resting on the sensor. |
| Alat pareum teu disangka-sangka | Low battery; automatic power-off due to inactivity. | Replace batteries; ensure finger is inserted for measurement. |
8. Spésifikasi
| Nomer modél | 34285 (OXY 6) |
| Tipe tampilan | OLED Color Display |
| Parameter pangukuran | SpO2, Pulse Rate, Perfusion Index (PI) |
| SpO2 Measurement Range | (Typical range, refer to device for exact range) |
| Pulse Rate Ukur Range | (Typical range, refer to device for exact range) |
| Akurasi | High precision and repeatability with noise suppression |
| Sarat kakuatan | 2 x AAA 1.5V Alkaline Batteries |
| Kahirupan batré | Approximately 3 hours of continuous operation with full batteries |
| Ukuran (L x W x H) | 16 x 5.5 x 10 cm |
| Beurat | 200 gram (kaasup batré) |
| Finger Thickness Range | 1-22 mm |
| Panungtun sora | 8 languages (GB, FR, IT, ES, GR, PT, Arabic) |
9. Garansi jeung Rojongan
Information regarding specific warranty terms and customer support for the GIMA OXY 6 Pulse Oximeter is not provided in this document. Please refer to the product packaging or contact GIMA customer service for details.