Produk Leuwihview
This manual provides essential information for the safe and effective use of the Norton 271Y Aftermarket Furnace Hot Surface Ignitor. This component is a brand new aftermarket replacement designed for furnace applications, ensuring reliable ignition.

Image: The Norton 271Y Aftermarket Furnace Hot Surface Ignitor, showing the ceramic base, heating element, and attached wiring with two white wire connectors.
Émbaran Kasalametan
WARNING: Installation and servicing of heating equipment can be hazardous and requires specialized knowledge and training. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Read and understand these instructions thoroughly before attempting any installation or service. Only qualified service personnel should install or service this ignitor.
- Always disconnect power to the furnace before beginning any installation or maintenance.
- Anggo alat pelindung diri (APD) anu merenah, kalebet sarung tangan sareng pelindung panon.
- Ensure proper grounding and wiring connections are made according to local electrical codes and manufacturer specifications.
- Do not touch the ignitor element with bare hands, as oils can reduce its lifespan.
Setup sareng Instalasi
This section outlines the general steps for replacing a furnace ignitor. Specific procedures may vary depending on your furnace model. Refer to your furnace's service manual for detailed instructions.
- Pegatkeun daya: Locate the main power switch for your furnace and turn it off. For added safety, turn off the circuit breaker supplying power to the furnace.
- Access Ignitor: Open the furnace access panel to locate the existing ignitor. It is typically found near the burner assembly.
- Disconnect Old Ignitor: Carefully disconnect the wiring from the old ignitor. Note the orientation and connection points. Remove any mounting screws or clips securing the old ignitor.
- Install New Ignitor: Mount the new Norton 271Y ignitor in the same position as the old one, ensuring it is securely fastened.
- Sambungkeun Wiring: Connect the new ignitor's wiring to the furnace's electrical system. Use the provided connectors if necessary, ensuring a secure and insulated connection. Double-check all connections for tightness and correct polarity.
- Panel Aman: Tutup sareng amankeun sadaya panel aksés tungku.
- Mulangkeun Daya: Restore power to the furnace at the circuit breaker and main power switch.
- Operasi tés: Initiate a heating cycle to verify the ignitor functions correctly and the furnace lights properly. Observe for any unusual sounds or smells.
Prinsip Operasi
The Norton 271Y Hot Surface Ignitor operates by heating a silicon carbide element to a very high temperature when electrical current is applied. This glowing element then ignites the gas flowing into the furnace's burners. Once ignition is confirmed by the furnace's flame sensor, the ignitor typically de-energizes until the next call for heat.
Pangropéa
Regular inspection of your furnace's components, including the ignitor, can help ensure reliable operation. While the ignitor itself is not typically a user-serviceable part for cleaning or repair, periodic visual checks are recommended.
- Inspeksi taunan: During your annual furnace maintenance, have a qualified technician inspect the ignitor for signs of wear, cracks, or discoloration.
- Ngahindarkeun kontaminasi: Ensure the area around the ignitor is free from dust, debris, or oil residue, which can affect its performance and lifespan.
Pamérésan masalah
If your furnace is not igniting, the ignitor may be a potential cause. Always consult a qualified technician for diagnosis and repair.
| Gejala | Mungkin Cukang lantaranana | Aksi |
|---|---|---|
| Furnace not igniting, ignitor does not glow. | No power to ignitor, faulty ignitor, or control board issue. | Check furnace power supply. Inspect ignitor for visible damage. Consult a qualified technician for electrical diagnostics. |
| Ignitor glows but furnace does not light. | Gas supply issue, faulty gas valve, or flame sensor problem. | Ensure gas supply is on. Consult a qualified technician to check gas valve and flame sensor operation. |
| Ignitor glows intermittently or weakly. | Aging ignitor, poor electrical connection, or voltage ngaluarkeun. | Inspect wiring connections. A weak glow often indicates an ignitor nearing the end of its lifespan. Replacement by a technician may be necessary. |
spésifikasi
| Atribut | Rincian |
|---|---|
| Jenis produk | Aftermarket Furnace Hot Surface Ignitor |
| Nomer modél | CECOMINOD037601 |
| merek | Norton |
| Dimensi produk | 6 x 6 x 6 inci |
| Item Beurat | 6 ons |
| Produsén | Universal |
| Tanggal Sadia munggaran | Pébruari 25, 2015 |
Émbaran jaminan
Specific warranty details for this aftermarket ignitor are not provided in the product data. For information regarding warranty coverage, terms, and conditions, please contact the seller or the manufacturer directly. It is advisable to retain your proof of purchase for any warranty claims.
Rojongan Palanggan
For technical assistance, installation guidance, or troubleshooting beyond the scope of this manual, please contact the seller from whom you purchased this product or a qualified HVAC technician. Always provide your product model number (CECOMINOD037601) and purchase details when seeking support.
Anjeun oge bisa nganjang ka Norton Store on Amazon for additional product information, though direct support for aftermarket parts may be handled by the specific seller.