GREISINGER GPHU 014 MP/BNC

Logo GREISINGER

Greisinger GPHU 014 MP/BNC pH Measurement Converter Instruction Manual

Model: GPHU 014 MP/BNC

1. Bubuka

This manual provides comprehensive instructions for the safe and efficient operation of your Greisinger GPHU 014 MP/BNC pH Measurement Converter. Please read this manual thoroughly before using the device to ensure proper functionality and to prevent damage. Keep this manual for future reference.

The GPHU 014 MP/BNC is designed to convert pH electrode signals into a standardized output, allowing for precise pH monitoring in various applications. It is intended for use with compatible pH electrodes featuring a BNC connector.

2. Émbaran Kasalametan

  • Always operate the device within its specified environmental conditions.
  • Entong ngalaan alat ka suhu anu ekstrim, sinar panonpoé langsung, atanapi kalembaban anu luhur.
  • Hindarkeun ragrag atanapi ngagentoskeun alat kana tabrakan anu kuat.
  • Ensure proper electrical connections are made according to the instructions to prevent electrical shock or damage.
  • Ulah nyobian muka atawa ngalereskeun alat sorangan. Rujuk sadayana jasa ka tanaga anu mumpuni.
  • Use only compatible pH electrodes and accessories with this converter.
  • Dispose of the device and any associated components in accordance with local environmental regulations.

3. Eusi Paket

Mangga parios eusi bungkusan nalika nampi. Upami aya barang anu leungit atanapi ruksak, langsung hubungi supplier anjeun.

  • Greisinger GPHU 014 MP/BNC pH Measurement Converter
  • Manual Pitunjuk (dokumén ieu)
  • Mounting accessories (if applicable, check packaging)

Note: A pH electrode is not included with this converter and must be purchased separately.

4. Produk Langkungview

The Greisinger GPHU 014 MP/BNC is a compact and robust pH measurement converter designed for industrial and laboratory applications. It features a clear digital display and intuitive controls for easy operation.

Greisinger GPHU 014 MP/BNC pH Measurement Converter front view

Gambar 1: Hareupeun view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter. The display shows "7.46 pH" and includes "ATC" and "Temp" indicators. Below the display are three buttons labeled "SET 1", "▼ 2", and "▲ 3". A BNC connector is visible on the right side for electrode connection. Two small ports are visible at the bottom.

Greisinger GPHU 014 MP/BNC pH Measurement Converter side view

Gambar 2: Samping view of the Greisinger GPHU 014 MP/BNC pH Measurement Converter, highlighting the BNC connector and the robust housing. The connector is labeled "AMPHENOL".

Komponén konci:

  • Digital tampilan: Shows pH value, temperature, and status indicators.
  • Tombol SET (1): Dipaké pikeun ngasupkeun jeung ngonfirmasi setélan.
  • Down Button (2): Used to navigate menus and decrease values.
  • Up Button (3): Used to navigate menus and increase values.
  • Panyambung BNC: For connecting a compatible pH electrode.
  • Input kakuatan: (Location not visible in images, refer to device for exact position)

5. Setélan

5.1. Pamasangan

The converter can be mounted using the integrated mounting points (screws visible in Figure 1). Ensure the mounting location is stable, free from excessive vibration, and within the specified operating temperature range.

5.2. Connecting the pH Electrode

  1. Ensure the converter is powered off.
  2. Carefully connect your pH electrode's BNC connector to the BNC input on the right side of the GPHU 014 MP/BNC converter (refer to Figure 1 and 2).
  3. Pastikeun sambunganna aman tapi ulah kenceng teuing.

5.3. Sambungan Daya

Connect the appropriate power supply to the converter. Refer to the device labeling for specific voltage and current requirements. Ensure the power source is stable and matches the device's specifications.

5.4. Kalibrasi Awal

Before first use, or after prolonged storage, the pH converter and electrode system must be calibrated. Refer to your pH electrode's manual for specific calibration buffer requirements.

  1. Daya dina alat.
  2. Access the calibration menu using the SET button. (Specific steps may vary, consult the device's on-screen prompts or a more detailed technical manual if available).
  3. Follow the on-screen instructions to perform a 2-point or 3-point calibration using standard pH buffer solutions (e.g., pH 4.01, 7.00, 10.01).
  4. Rinse the electrode thoroughly with distilled water between buffer solutions.
  5. Confirm calibration settings.

6. Nyuping

6.1. Nyandak Pangukuran

  1. Ensure the pH electrode is properly connected and calibrated.
  2. Immerse the pH electrode into the sample solution, ensuring the sensing bulb and reference junction are fully submerged.
  3. Allow sufficient time for the reading to stabilize on the digital display. The display will show the current pH value.
  4. Note any temperature readings if the electrode has an integrated temperature sensor and ATC (Automatic Temperature Compensation) is active.

6.2. Menu Napigasi

The SET, ▼, and ▲ buttons are used to navigate through the device's menu options. Press SET to enter the menu or confirm a selection. Use ▼ and ▲ to scroll through options or adjust values.

  • SET (1): Enter/Exit menu, confirm selection.
  • ▼ (2): Scroll down, decrease value.
  • ▲ (3): Scroll up, increase value.

Specific menu functions (e.g., setting alarm limits, output configuration) will be detailed in a more advanced technical manual or on-screen prompts.

7. Pangropéa

7.1. Cleaning the Converter

Wipe the exterior of the converter with a soft, damp lawon. Ulah nganggo pembersih atanapi pangleyur anu abrasif. Pastikeun teu aya cairan anu asup kana alat.

7.2. Pangropéa éléktroda pH

Proper maintenance of the pH electrode is crucial for accurate readings and extended lifespan. Refer to your specific pH electrode's instruction manual for detailed care instructions. General guidelines include:

  • Always keep the electrode's sensing bulb hydrated, typically in a storage solution or pH 7 buffer. Never store dry.
  • Rinse the electrode with distilled or deionized water after each measurement.
  • Clean the electrode regularly to remove sample residues. Specific cleaning solutions may be required depending on the application.
  • Recalibrate the electrode regularly, especially if readings become unstable or inaccurate.

7.3. Panyimpenan

When not in use for extended periods, store the converter in a clean, dry environment at room temperature. Ensure the pH electrode is properly stored according to its manufacturer's recommendations.

8. Cara ngungkulan

Masalah Mungkin Cukang lantaranana Solusi
No display/Device not powering on No power, faulty power supply, incorrect connection. Pariksa kabel listrik sareng sumberna. Pastikeun voltasena lerestage.
Unstable or inaccurate pH readings Electrode not calibrated, dirty electrode, damaged electrode, air bubbles, incorrect temperature compensation. Recalibrate electrode. Clean electrode. Replace electrode if damaged. Ensure electrode is fully submerged. Check ATC settings.
Pesen "Kasalahan" dina tampilan Electrode fault, out of range measurement, internal device error. Check electrode connection. Try another electrode if available. Refer to specific error codes in a detailed technical manual. Contact support if persistent.
waktos respon lalaunan Aged or dirty electrode, low sample suhu. Clean or recondition electrode. Allow electrode to equilibrate with sample temperature. Consider replacing electrode.

If the problem persists after attempting these solutions, please contact Greisinger customer support or your local distributor.

9. Spésifikasi

Fitur Rincian
Produsén GREISINGER
Nomer Modél Item 602331
Ukuran produk (L x W x H) 5.5 x 8.2 x 8 cm; 9.07 gram
ASIN B00ICKLET6
Jumlah barang 1
Batré kaasup No
Battery(ies) required No
Date first available on Amazon.com.be 12 Agustus 2022
Discontinued by manufacturer No
Kasadiaan suku cadang Inpormasi henteu sayogi dina suku cadang

10. Garansi jeung Rojongan

Greisinger products are manufactured to high-quality standards. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Greisinger websitus.

For technical support, troubleshooting assistance beyond this manual, or to inquire about spare parts and service, please contact your authorized Greisinger dealer or the manufacturer directly. Contact information can typically be found on the product packaging or the official Greisinger websitus.

Dokumén Patali - GPHU 014 MP/BNC

Praview GREISINGER GE xxx Manual Operasi: pH Éléktroda
Manual operasi komprehensif pikeun éléktroda pH séri GREISINGER GE xxx, ngawengku kaamanan, dasar, pangukuran, kalibrasi, pangropéa, pilihan, sareng spésifikasi. Ngawengku pituduh lengkep pikeun pangukuran pH anu akurat.
Praview GREISINGER EBUW 232 EASYBUS Protocol Converter Operating Manual
Operating manual for the GREISINGER EBUW 232 EASYBUS protocol converter, detailing its specifications, general information, and safety requirements.
Praview GREISINGER GIA 20 EB / PK Manual: Sambungan jeung Operasi
Manual ieu nyadiakeun parentah komprehensif pikeun GREISINGER GIA 20 EB / PK microprocessor-dikawasa mintonkeun, monitoring, jeung alat kontrol. Ieu nyertakeun peraturan kaamanan, sambungan listrik pikeun sagala rupa sinyal input jeung tipe kaluaran, konfigurasi alat ngagunakeun software, switchpoint jeung setélan alarem, offset / adjustment lamping, panganteur serial, kode kasalahan, spésifikasi, jeung catetan pembuangan.
Praview GREISINGER GMH 3710 Precision Thermometer Operating Manual
Manual operasi ieu nyadiakeun parentah lengkep pikeun térmométer precision GREISINGER GMH 3710. Ieu nyertakeun pamakéan dimaksudkeun, precautions kaamanan, spésifikasi produk, penanganan, konfigurasi, pilihan kaluaran, pangaluyuan input, sambungan usik, prinsip pangukuran suhu dasar, pesen lepat, sarta tungtunan pembuangan pikeun sensor hawa Pt100.
Praview Greisinger GDH 200 Series Manometers and Barometers: Technical Overview
Discover the Greisinger GDH 200 series handheld pressure measurement instruments. This document details the GDH 200-07 fine manometer, GDH 200-13 manometer, and GDH 200-14 vacuum/barometer, highlighting their specifications and features for professional use.
Praview GREISINGER GMH 38-LW1 / -LW2 Moisture Meter Operating Manual Appendix
Appendix manual operasi pikeun GREISINGER GMH 38-LW1 / -LW2 set ukur kelembaban pikeun aplikasi tatanén. Nyertakeun tujuan pamakéan, kaamanan, déskripsi produk, penanganan, prinsip pangukuran, sarta spésifikasi pikeun chip kai, gandum, jarami, sarta jarami.