1. Produk Langkungview
The Blue Wave NE6181 Tidal Wave 2-Speed Replacement Pump is designed for above-ground pools, offering efficient water circulation with energy-saving capabilities. Its dual-speed functionality allows users to select the appropriate power level for various tasks, from daily filtration to vacuuming.
fitur konci ngawengku:
- Desain Dual-Port: Compatible with most filter systems, allowing for vertical or horizontal application.
- Energy Saving Technology: Two-speed operation to optimize energy consumption.
- Kinerja anu dipercaya: Engineered for consistent and powerful water movement.
- Gampang pikeun ngabersihan: Features a clear lid for convenient access to the strainer basket.
- Konstruksi awét: Corrosion-proof polymer construction for extended lifespan.

Image 1.1: The Blue Wave NE6181 Tidal Wave 2-Speed Replacement Pump, showcasinkalayan desain anu ringkes sareng kabel listrik anu terintegrasi.
2. Émbaran Kasalametan
WARNING: Read and follow all instructions before installing and operating this product. Failure to follow these instructions can result in serious injury or death.
- Salawasna pegatkeun listrik ka pompa sateuacan ngalaksanakeun pangropéa atanapi jasa naon waé.
- Pastikeun pompa dipasang dina permukaan anu padet.
- Ulah ngajalankeun pompa lamun ari kakuatan ruksak.
- This pump is designed for use with above-ground pools only.
- Ensure proper grounding and use a Ground Fault Circuit Interrupter (GFCI) for electrical connections.
- Keep children away from the pump and all electrical connections.
- Do not run the pump dry. Ensure it is primed with water before operation.
3. Setup jeung Instalasi
Pamasangan anu leres penting pisan pikeun kinerja sareng umur pompa. Turutan léngkah-léngkah ieu kalayan saksama:
- panempatan: Position the pump on a firm, level surface as close to the pool as possible to minimize friction loss from long plumbing runs. Ensure adequate ventilation around the pump.
- Sambungan Pipa: The Tidal Wave pump features dual ports for flexible installation (vertical or horizontal). Connect the pump to your existing filter system using appropriate plumbing fittings. Ensure all connections are tight to prevent leaks.
- Sambungan listrik: The pump operates on 110-120V AC. Connect the 6ft cord to a properly grounded 3-prong outlet protected by a GFCI. Do not use extension cords.
- Nyiapkeun pompa: Before starting, ensure the pump basket is filled with water. This pump is self-priming, but initial priming assists in faster startup.

Gambar 3.1: Sisi view of the Blue Wave NE6181 pump, showing the motor and pump housing with connection ports.
4. Parentah Operasi
The Tidal Wave pump features two operating speeds to optimize performance and energy efficiency.
- Laju low: Ideal for everyday filtration and maintaining water circulation. This setting consumes less energy and is quieter, suitable for continuous operation.
- Gancang: Use this setting when more power is required, such as during vacuuming, backwashing the filter, or when rapid water circulation is needed.
To switch between speeds, use the designated switch on the pump motor. Always ensure the pump is fully primed before starting operation.
5. Pangropéa
Pangropéa rutin mastikeun kinerja anu optimal sareng manjangkeun umur pompa anjeun.
- Ngabersihkeun Karanjang Saringan: The pump features an extra-large clear lid for easy inspection of the strainer basket. Regularly check and clean the basket to remove debris (leaves, hair, etc.) that can impede water flow and strain the motor. To clean, disconnect power, unscrew the clear lid, remove the basket, empty debris, rinse, and replace. Ensure the O-ring is properly seated and the lid is securely tightened.
- Ventilasi motor: Ensure the motor's ventilation openings are clear of obstructions to prevent overheating.
- Winterization: In colder climates, drain the pump completely and store it in a dry, protected area during winter months to prevent freeze damage.
6. Cara ngungkulan
Tingali tabel di handap pikeun masalah umum sareng solusina.
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Pompa teu ngamimitian | Taya kakuatan; tripped GFCI; kaleuleuwihan motor. | Check power supply; reset GFCI; allow motor to cool and reset. |
| Aliran cai lemah | Clogged strainer basket; air leak in suction line; dirty filter. | Clean strainer basket; check for air leaks; clean or backwash filter. |
| Pompa leungiteun perdana | Air leak in suction line; low water level in pool. | Check and seal all suction side connections; ensure adequate pool water level. |
| Sora kaleuleuwihi | Cavitation (air in pump); worn bearings; debris in impeller. | Check for air leaks; inspect impeller for debris; contact service if bearings are worn. |
7. Spésifikasi
Detailed technical specifications for the Blue Wave NE6181 Tidal Wave 2-Speed Replacement Pump.

Image 7.1: Technical diagram illustrating the dimensions (24x8x11 inches) and key electrical specifications (10A/3.2A, 115V, 1 HP, 1720-3450 RPM, 34.45 ft max head, 2000-4500 GPH water flow) of the pump.
| Atribut | Nilai |
|---|---|
| Nomer modél | NE6181 |
| Daya kuda (HP) | 1 hp |
| Voltage | 115 volt |
| Amperage (High/Low) | 10A / 3.2A |
| RPM (High/Low) | 3450 / 1720 rpm |
| Maksimum Ngangkat Jangkungna | 34.45 suku |
| Water Flow (GPH) | 2000-4500 GPH |
| Bahan | Poliétilén |
| Ukuran (L x W x H) | 24 x 8 x 11 inci |
| Item Beurat | 22 pon |
| Sumber Daya | Kabel Listrik |
8. Garansi jeung Rojongan
This Blue Wave NE6181 Tidal Wave 2-Speed Replacement Pump comes with a manufacturer's warranty.
- Garansi: The manufacturer warrants this pump to be free from defects in workmanship and materials, under normal residential use and conditions, for a period of 1 taun from the date of purchase. Please retain your proof of purchase for warranty claims. Note: This pump is not for use or sale in California due to motor limitations required by the California Energy Commission.
- Manual pamaké: For a comprehensive guide and additional details, please refer to the official user manual available as a PDF document: Unduh Buku Panduan Pamaké (PDF).
- Rojongan Palanggan: For technical assistance, parts, or warranty inquiries, please contact Blue Wave customer service. Refer to the contact information provided in the official user manual or on the Blue Wave websitus.