Hach 2291700 Hydrogen Peroxide Test Kit, Model HYP-1 Instruction Manual

Bubuka

This manual provides detailed instructions for the proper use, maintenance, and troubleshooting of the Hach 2291700 Hydrogen Peroxide Test Kit, Model HYP-1. This kit is designed for measuring hydrogen peroxide concentration using a reliable drop count titration method. Adhering to these instructions will ensure accurate results and safe operation.

Émbaran Kasalametan

Always prioritize safety when handling chemicals and performing tests. Read all reagent labels carefully before use. Wear appropriate personal protective equipment (PPE), such as safety glasses and gloves, to prevent contact with chemicals. In case of contact, refer to the Safety Data Sheet (SDS) for the specific reagent and follow first aid instructions. Keep all chemicals out of reach of children and pets. Dispose of chemical waste according to local regulations.

Komponén Kit

The Hach 2291700 Hydrogen Peroxide Test Kit, Model HYP-1, includes the following items:

Hach 2291700 Hydrogen Peroxide Test Kit components laid out, including a light blue carrying case, reagent bottles, an Erlenmeyer flask, test tubes, a dropper, and a bag of reagent packets.

This image displays the complete Hach 2291700 Hydrogen Peroxide Test Kit. It includes a durable light blue carrying case, two reagent bottles labeled 'HACH', a 50 mL Erlenmeyer flask, two clear test tubes, a dropper, and a sealed bag containing multiple reagent packets. These components are essential for performing the hydrogen peroxide concentration test.

Disetél

Before beginning the test, ensure you have a clean, well-lit workspace and all kit components are readily accessible.

  1. Open the carrying case and remove all reagents and apparatus.
  2. Inspect all glassware for cleanliness. Wash with distilled water if necessary and allow to air dry.
  3. Ensure reagent bottles are tightly capped when not in use to prevent contamination or degradation.

Operating Instructions (Drop Count Titration Method)

Follow these steps carefully to perform the hydrogen peroxide test:

  1. Sample Koléksi: Collect a representative water sample in a clean test tube or beaker. The sample volume required will depend on the specific test procedure (refer to the detailed instructions provided with the kit reagents).
  2. Sample Persiapan: Transfer the specified volume of sample into the 50 mL Erlenmeyer flask.
  3. Add Reagent 1 (e.g., Sulfuric Acid): Using the dropper, add the specified number of drops of Reagent 1 to the sample in the flask. Swirl gently to mix.
  4. Add Reagent 2 (e.g., Sulfite 1 Indicator): Add the specified number of drops or one packet of Reagent 2 (indicator) to the flask. Swirl to dissolve and mix. The sample should develop a distinct color.
  5. Titration: Hold the Sodium Thiosulfate Titrant bottle vertically over the flask. Add the titrant drop by drop, swirling the flask after each drop. Count the number of drops added.
  6. Titik ahir: Continue adding titrant until the color of the solution in the flask changes sharply and remains stable for at least 30 seconds. This is the endpoint of the titration.
  7. Rékam Hasil: Note the exact number of drops of Sodium Thiosulfate Titrant used to reach the endpoint.

Hasil Bacaan

The concentration of hydrogen peroxide is determined by the number of drops of titrant used. Refer to the conversion chart or formula provided with your specific Hach reagents to convert the number of drops into the corresponding hydrogen peroxide concentration (e.g., mg/L or ppm). Each drop typically corresponds to a specific concentration increment.

Pangropéa

Pamérésan masalah

MasalahMungkin Cukang lantarananaSolusi
Hasil anu teu akurat atanapi teu konsistenContaminated glassware, expired reagents, incorrect sample volume, improper mixing, incorrect drop counting.Ensure all glassware is clean. Check reagent expiration dates. Verify sample and reagent volumes. Mix thoroughly. Count drops carefully.
Endpoint color change is unclear or difficult to observeInsufficient indicator, incorrect pH, interfering substances in sample, poor lighting.Ensure correct amount of indicator is added. Check for pH issues if applicable. Use a clean, well-lit area. Consider diluting sample if highly colored.
Reagents not dissolving properlyInsufficient mixing, cold sample suhu.Swirl or shake vigorously. Allow sample to reach room temperature if it was very cold.

spésifikasi

Garansi sareng Rojongan

For specific warranty information and technical support, please refer to the documentation included with your purchase or visit the official Hach website. Hach provides comprehensive support resources to ensure the optimal performance of their products.

Hach Company Contact Information:

Dokumén Patali - 2291700

Praview Pakakas Tés Karasa HACH (Total sareng Kalsium) HA-4P MG/L (145701) - Pitunjuk sareng Spésifikasi
Detailed instructions and specifications for the HACH Hardness (Total and Calcium) Test Kit, Model HA-4P MG/L (145701). Learn how to perform total and calcium hardness tests, understand interferences, and order replacement items.
Praview How to Reprogram Hach DR-3000 for Accu-TEST COD Vials
Instructions and services for reprogramming the Hach DR-3000 spectrophotometer or colorimeter to use Bioscience, Inc.'s accu-TEST COD vials. Includes support and reprogramming service details from Bioscience, Inc.
Praview HACH EZ sc Séri EZ1022sc Analiser Hidrogén Peroksida Kolometrik Online
Spésifikasi téknis, fitur, sareng inpormasi pesenan pikeun penganalisis hidrogén péroksida kolorimetrik online HACH EZ sc Series EZ1022sc, anu dirancang pikeun aplikasi cai limbah, cai nginum, sareng cai prosés.
Praview Titrators Manual HACH: Solusi Titrasi Akurat sareng Merenah
Jelajah Titrators Manual HACH pikeun titrasi akurat ± 1%. Panggihan model 1690001, 1690002, jeung 2270900, dirancang pikeun genah tur efisiensi dina nguji laboratorium.
Praview Oxygen, Demand Chemical: Manganese III Reactor Digestion Method (Method 10067)
Detailed instructions and specifications for the Hach Manganese III Reactor Digestion Method for determining Chemical Oxygen Demand (COD) in water and wastewater, covering test preparation, procedure, interferences, and method performance. Includes instrument compatibility and required reagents/apparatus.
Praview AS950 Controller Operations Manual - HACH
Comprehensive operations manual for the HACH AS950 Controller, detailing setup, configuration, operation, calibration, and troubleshooting for AWRS, refrigerated, and portable samplers.