Casella CEL-246/K1 Digital Logging Integrating Sound Level Meter Type 2 Kit User Manual

Model: CEL-246/K1

Brand: Casella

1. Bubuka

This manual provides comprehensive instructions for the proper use, setup, operation, and maintenance of the Casella CEL-246/K1 Digital Logging Integrating Sound Level Meter Type 2 Kit. This device is designed for precise sound level measurements, incorporating Digital Signal Processing (DSP) technology for accurate and reliable data.

The CEL-246/K1 offers a wide measurement range, selectable frequency weightings (A and C), and time responses (Slow, Fast, Impulse). It features a non-decaying maximum hold function and a clear display showing current, highest, and average noise levels, along with a time history trend. Data logging capabilities are available via a USB output port.

2. Naon Kaasup

The Casella CEL-246/K1 Kit includes the following components:

  • One (1) Casella CEL-246/K1 Sound Level Meter
  • One (1) Acoustic Calibrator
  • One (1) Foam Windscreen
  • Hiji (1) Kantong
  • One (1) Calibration Certificate
  • Three (3) AA Batteries

3. Setélan

3.1 Pamasangan batré

  1. Locate the battery compartment on the rear of the sound level meter.
  2. Buka panutup kompartemen.
  3. Insert three (3) AA batteries, ensuring correct polarity (+/-).
  4. Tutup panutup kompartemen batré aman.

3.2 Attaching the Foam Windscreen

Gently slide the foam windscreen over the microphone at the top of the sound level meter. This helps to reduce wind noise during outdoor measurements.

3.3 Daya Awal Hurung

Press the power button to turn on the device. The display will illuminate, showing the current measurement mode and readings.

Casella CEL-246/K1 Digital Logging Integrating Sound Level Meter with foam windscreen attached

An image showing the Casella CEL-246/K1 Digital Logging Integrating Sound Level Meter. The device is blue and grey, with a display screen showing measurement data and a graph. A black foam windscreen is attached to the top microphone.

4. Parentah Operasi

4.1 Operasi Dasar

The CEL-246/K1 features simple two-button operation for ease of use. Refer to the on-screen prompts and the full user guide for detailed button functions.

4.2 Frequency Weighting

The meter supports two frequency weighting scales:

  • A-Weighting: Attenuates lower frequencies to approximate the human ear's response, which is most sensitive between 3000 and 4000 Hz. Use for general noise measurements.
  • C-Weighting: Reads all frequencies more uniformly, providing a better response to higher frequencies than A-weighting. Useful for pinpointing problems when A-weighted readings are very high.

4.3 Time Weighting

Selectable time responses include:

  • Lalaunan: Provides a slower response, suitable for measuring steady noise levels.
  • gancang: Offers a quicker response, ideal for capturing fluctuating noise levels.
  • dorongan: Designed for very short, sharp noise events.

4.4 Maximum Hold Feature

The non-decaying maximum hold feature captures and displays the highest sound pressure level detected until manually reset. This is useful for identifying peak noise events.

4.5 Data Logging and USB Output

The meter includes a USB output port for simple data logging. Connect the device to a PC to download stored data or for real-time data analysis using the optional software package. Data can be exported in spreadsheet format for further analysis.

4.6 Kalibrasi Otomatis

The CEL-246/K1 supports auto calibration at a selected decibel level using the included acoustic calibrator. Refer to the full user guide for detailed calibration procedures to ensure measurement accuracy.

5. Pangropéa

5.1 beberesih

Lap bagian luar méter ku lawon anu lemes sareng garing. Entong nganggo pembersih atanapi pangleyur anu abrasif. Pastikeun teu aya Uap anu asup kana alat.

5.2 Ngagantian batré

Replace batteries when the low battery indicator appears on the display. Always use three (3) new AA batteries of the same type.

5.3 Panyimpenan

When not in use for extended periods, remove the batteries to prevent leakage. Store the meter in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.

5.4 Kalibrasi

Regular calibration is crucial for maintaining measurement accuracy. Use the provided acoustic calibrator according to the instructions in Section 4.6 and the full user guide. It is recommended to calibrate the device before each critical measurement session.

6. Cara ngungkulan

6.1 Meter Not Powering On

  • Check if the batteries are correctly inserted with proper polarity.
  • Ganti ku batré AA seger.
  • Pastikeun tombol daya dipencet pageuh.

6.2 Bacaan teu akurat

  • Perform an auto calibration using the acoustic calibrator.
  • Ensure the foam windscreen is properly attached to minimize wind noise.
  • Verify that the correct frequency (A or C) and time weighting (Slow, Fast, Impulse) are selected for your measurement environment.
  • Check for any physical damage to the microphone or device.

6.3 Data Logging Issues

  • Ensure the USB cable is securely connected to both the meter and the PC.
  • Verify that the necessary software drivers are installed on your PC.
  • Consult the software manual for specific data transfer instructions.

7. Spésifikasi

FiturSpésifikasi
Nomer modélCEL-246/K1
Rentang pangukuran30 nepi ka 130 dB
Timbangan FrékuénsiA atanapi C
Waktos WeightingsSlow, Fast, Impulse
tampilanCurrent, Highest, Average Noise Level, Time History Trend
Kaluaran PortUSB for data logging
Sumber Daya3 x Batré AA
Ukuran Paket17 x 12.5 x 4 inci
Beurat pakét3.9 pon
Negara asalkarajaan Inggris
ProdusénCole-Parmer

8. Garansi jeung Rojongan

For warranty information and technical support, please refer to the documentation provided with your purchase or contact Casella customer service directly. Keep your purchase receipt as proof of purchase.

Manufacturer: Cole-Parmer

Dokumén Patali - CEL-246/K1

Praview Casella Apex2 Medium Flow Air Sampling Pompa
The Casella Apex2 is a medium flow air sampling pump offering class-beating performance, intrinsic safety for flammable atmospheres, and remote monitoring capabilities via the Airwave mobile software. Features include Bluetooth connectivity, data logging, and robust design for occupational hygiene measurements.
Praview Casella Insight Vérsi 17 Guide instalasi - Setup software
Pituduh instalasi resmi pikeun software Casella Insight Vérsi 17. Diajar kumaha ngundeur, masang, sareng ningkatkeun aplikasi Insight kalayan petunjuk léngkah-léngkah sareng ngadukung wincik kontak.
Praview Casella dBadge2 Personal Noise Dosimeter Field Guide
Pitunjuk lapangan pikeun dosimeter bising pribadi Casella dBadge2, nyertakeun setelan, operasi, ngecas, kalibrasi, sareng undeuran data. Ngawengku inpormasi ngeunaan modél, fitur, sareng aplikasi Airwave.
Praview Casella Apex2 Medium Flow Air Sampling Pump | Datasheet
Detailed information on the Casella Apex2 Medium Flow Air Sampling Pump, featuring class-beating performance, intrinsic safety for flammable atmospheres, and Bluetooth connectivity with Airwave software.
Praview TSI OmniWear Noise™ Personal Noise Dosimeter: Features, Specifications, and Applications
Discover the TSI OmniWear Noise™ Personal Noise Dosimeter, a compact, wearable device for accurate noise exposure monitoring in industrial and occupational settings. Learn about its features, app integration, wireless charging, calibration, reporting capabilities, and detailed technical specifications for workplace safety.
Praview TSI OmniWear Noise™ Personal Dosimeter User Manual: Setup, Operation, and Compliance Guide
This comprehensive user manual guides you through the setup, operation, and maintenance of the TSI OmniWear Noise™ Personal Dosimeter. Discover how to effectively monitor workplace noise levels, ensure regulatory compliance, and protect employee hearing with this advanced personal noise measurement solution.