HACH HQ411d, 8507560

Hach HQ411d Benchtop Meter and PHC201 Gel pH Probe Instruction Manual

1. Bubuka

This instruction manual provides essential information for the proper setup, operation, and maintenance of your Hach HQ411d Benchtop Meter package, which includes the PHC201 Gel pH Probe. Adhering to these guidelines will ensure accurate measurements and extend the lifespan of your equipment. Please read this manual thoroughly before initial use.

2. Eusi Paket

Upon unpacking, verify that all components listed below are present and undamaged. If any items are missing or damaged, contact Hach customer support immediately.

  • Hach HQ411d Benchtop Meter
  • PHC201 Gel pH Probe
  • Electrode Stand
  • pH Buffer Solutions (typically pH 4, 7, and 10)
  • pH Storage Solution
  • Adaptor kakuatan
  • Kabel USB
Hach HQ411d Benchtop Meter Package with PHC201 Gel pH Probe, Electrode Stand, and Buffer Solutions

Gambar 2.1: The Hach HQ411d Benchtop Meter package. This image displays the main HQ411d meter unit with its digital display showing a pH reading of 7.01 and a temperature of 25.1°C. To the left, an adjustable electrode stand is visible. A PHC201 Gel pH Probe is connected to the meter. Additionally, four bottles are shown: three containing colored pH buffer solutions (yellow for pH 7, blue for pH 4, and red for pH 10) and one containing clear pH storage solution.

3. Fitur konci

The Hach HQ411d Benchtop Meter offers several features designed for reliable and user-friendly pH measurement:

  • Intuitive user interface for straightforward operation and accurate results.
  • IntelliCAL smart probes store all calibration data directly within the probe, ensuring measurement integrity.
  • Ultra-bright screen with a large font size for enhanced readability of measurements.
  • Internal USB ports for convenient data transfer and connectivity.
  • This convenient kit includes all necessary components to begin testing immediately.

4. Setélan

Follow these steps for initial setup of your Hach HQ411d Benchtop Meter.

  1. Ngabongkar sareng Inspeksi: Carefully remove all components from the packaging. Inspect each item for any signs of damage. Retain packaging materials for future transport or storage.
  2. Connecting the Electrode Stand: Assemble the electrode stand according to its specific instructions. Position it securely next to the meter.
  3. Connecting the PHC201 Gel pH Probe: Connect the PHC201 Gel pH Probe to the designated port on the Hach HQ411d meter. Ensure the connection is secure.
  4. Ngahurungkeun: Connect the power adapter to the meter and then to a suitable power outlet. Press the power button to turn on the meter.
  5. Kalibrasi awal: Before first use, and regularly thereafter, calibrate the pH probe using the provided buffer solutions (pH 4, 7, and 10). Refer to Section 5.2 for detailed calibration procedures.

5. Parentah Operasi

This section outlines the basic procedures for taking measurements and calibrating your meter.

5.1. Prosedur Pangukuran Dasar

  1. Prepare the Probe: If the probe has been stored dry or in storage solution, rinse it thoroughly with deionized water.
  2. Immerse the Probe: Carefully immerse the PHC201 Gel pH Probe into the sample solution, ensuring the sensing bulb and junction are fully submerged.
  3. Ngastabilkeun Maca: Allow sufficient time for the reading on the meter's display to stabilize. The meter will typically indicate when the reading is stable.
  4. Pangukuran Rékam: Once stable, record the pH and temperature readings displayed on the screen.
  5. Rinse and Store: After measurement, rinse the probe with deionized water and return it to its storage solution or follow maintenance guidelines.

5.2. Prosedur Calibration

Regular calibration is crucial for accurate pH measurements. The HQ411d meter uses IntelliCAL smart probes, which store calibration data.

  1. Prepare Buffer Solutions: Ensure buffer solutions (pH 4, 7, 10) are at the same temperature as your samples for best accuracy.
  2. Access Calibration Menu: Navigate to the calibration menu on the HQ411d meter using the interface buttons.
  3. First Buffer Point (pH 7): Rinse the probe with deionized water, then immerse it in the pH 7 buffer solution. Follow the on-screen prompts to accept the reading.
  4. Second Buffer Point (pH 4 or pH 10): Rinse the probe again. Immerse it in either the pH 4 or pH 10 buffer solution, depending on your expected sample range. Follow prompts to accept.
  5. Third Buffer Point (Optional): For wider range accuracy, rinse and immerse the probe in the remaining buffer solution (pH 4 or pH 10).
  6. Kalibrasi lengkep: Confirm and save the calibration. The meter will display calibration results.

5.3. Manajemén Data

The HQ411d meter features internal USB ports for data transfer. Consult the meter's on-screen menu or the full Hach user manual for specific instructions on logging data and transferring it to a computer.

6. Pangropéa

Proper maintenance ensures the longevity and accuracy of your Hach HQ411d system.

  • Probe Care and Storage: Always store the PHC201 Gel pH Probe in its designated storage solution when not in use. Never store the probe dry. Rinse the probe with deionized water before and after each use.
  • Meter Cleaning: Clean the exterior of the HQ411d meter with a soft, damp cloth. Avoid abrasive cleaners or solvents. Ensure no liquids enter the meter's ports.
  • Buffer Solution Handling: Always use fresh buffer solutions for calibration. Do not reuse buffer solutions, as their pH can change over time due to contamination or CO2 absorption. Store buffer solutions according to their labels.
  • Electrode Stand: Keep the electrode stand clean and free of chemical residues.

7. Cara ngungkulan

This section addresses common issues you might encounter with your Hach HQ411d Benchtop Meter.

MasalahMungkin Cukang lantarananaSolusi
Bacaan teu akuratProbe not calibrated; contaminated buffer solutions; dirty probe; expired probe.Perform a fresh calibration; use new buffer solutions; clean the probe; replace the probe if necessary.
Taya DayaPower adapter disconnected; faulty power outlet; meter malfunction.Check power connections; try a different outlet; contact Hach support.
Waktu Réspon LambatProbe dehydration; clogged junction; low sample suhu.Rehydrate probe in storage solution; clean probe junction; allow sampnepi ka ngahontal suhu kamar.
"Probe Error" MessageProbe not connected properly; damaged probe; meter issue.Ensure probe is securely connected; inspect probe for damage; restart meter; contact Hach support.

8. Spésifikasi

Key specifications for the Hach HQ411d Benchtop Meter and PHC201 Gel pH Probe package.

SpésifikasiNilai
Nomer Modél Item8507560
ProdusénHACH
Ukuran Paket20 x 20 x 20 inci
Beurat pakét20 pon
Tanggal Sadia munggaran16 Désémber 2014
ASINB00R3EGTHO

9. Garansi jeung Rojongan

Specific warranty details for the Hach HQ411d Benchtop Meter and PHC201 Gel pH Probe are not provided in this document. For warranty information, technical support, or service inquiries, please contact Hach customer service directly or visit the official Hach website. Ensure you have your product model number (HQ411d, 8507560) and purchase date available when contacting support.

Dokumén Patali - HQ411d, 8507560

Praview How to Reprogram Hach DR-3000 for Accu-TEST COD Vials
Instructions and services for reprogramming the Hach DR-3000 spectrophotometer or colorimeter to use Bioscience, Inc.'s accu-TEST COD vials. Includes support and reprogramming service details from Bioscience, Inc.
Praview Hach Model 2100N Laboratory Turbidimeter Instruction Manual
This instruction manual provides comprehensive guidance for the Hach Model 2100N Laboratory Turbidimeter, covering its operation, specifications, measurement procedures, calibration, maintenance, and troubleshooting for accurate turbidity analysis in laboratory environments.
Praview Buku Panduan Pangguna Probe Oksigén Terlarut Luminescent Hach Intellical LDO101 Series
Buku pituduh pikeun probe oksigén leyur digital luminescent séri Hach Intellical LDO101. Ngawengku produk di luhurview, spésifikasi, kaamanan, persiapan, kalibrasi, pangukuran, pangropéa, ngungkulan masalah, sareng barang konsumsi.
Praview HACH FH950 Portable Flow Meter Basic User Manual
This document is the Basic User Manual for the HACH FH950 portable flow meter. It provides essential information for operating, installing, and maintaining the device for accurate water flow and depth measurements in various environments.
Praview Manual Instruksi Méter Oksigén Terlarut Portabel Hach session6
Manual instruksi lengkep pikeun Hach session6 Portable Dissolved Oxygen Meter, anu ngawengku setelan, operasi, kalibrasi, pangropéa, sareng ngungkulan masalah pikeun pangukuran oksigén leyur anu akurat dina larutan cai.
Praview Hach PHC301 Intellical pH Probe User Manual
Comprehensive user manual for the Hach Intellical PHC301 series pH probes, detailing specifications, calibration procedures, maintenance, troubleshooting, and available consumables and accessories.