EUCHNER NZ1HS-3131-M

EUCHNER NZ1HS-3131-M Safety Switch Instruction Manual

Model: NZ1HS-3131-M

1. Bubuka

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the EUCHNER NZ1HS-3131-M Safety Switch. Please read this manual thoroughly before using the device to ensure proper function and to prevent potential hazards.

2. Émbaran Kasalametan

Awas: This device is a safety component. Improper installation or use can lead to serious injury or death. Always adhere to local and national safety regulations, including machine safety directives.

  • Pastikeun kakuatan dipegatkeun saméméh instalasi atawa perawatan.
  • Ngan tanaga anu mumpuni anu kedah masang, ngoperasikeun, sareng ngajaga alat ieu.
  • Ulah bypass atawa tamper with the safety functions of the switch.
  • Regularly inspect the switch for damage or wear.

3. Produk Langkungview

The EUCHNER NZ1HS-3131-M is a safety switch designed for monitoring the position of movable guards on machinery. It features a lever arm with a roller, providing reliable actuation. Its robust construction ensures durability in industrial environments.

EUCHNER NZ1HS-3131-M Safety Switch with lever arm and roller

Figure 1: EUCHNER NZ1HS-3131-M Safety Switch. This image shows the safety switch with its distinctive lever arm and roller, which is used for actuation.

Komponén konci:

  • Perumahan: Ngajaga komponén internal.
  • Lever Arm with Roller: The actuating element that detects guard position.
  • Port sambungan: For electrical wiring (M20 x 1.5).

4. Setup jeung Instalasi

Proper installation is critical for the safety switch's functionality. Follow these steps carefully:

  1. Pamasangan: Securely mount the safety switch to a stable surface near the movable guard. Ensure the lever arm can be actuated freely by the guard.
  2. Wiring:
    • Disconnect all power to the machine before wiring.
    • Connect the electrical wiring to the M20 x 1.5 connection port.
    • Use wires with a cross-section of 0.34 to 1.5 mm2.
    • Ensure connections comply with the rated voltage of 230V AC / 24V DC and current rating of 4 Amps.
    • Verify correct polarity for DC connections.
  3. Penyesuaian: Adjust the position of the switch and/or the guard so that the lever arm is actuated correctly when the guard is closed, and released when the guard is open. The switch should operate reliably throughout the guard's movement range.
  4. Uji coba: After installation, perform a functional test to ensure the safety switch operates as intended. Verify that the machine cannot start or stops immediately when the guard is opened.

5. Parentah Operasi

The NZ1HS-3131-M safety switch operates in an ON-OFF mode, designed to monitor the state of a machine guard. When the guard is closed, the lever arm is actuated, changing the state of the internal contacts (4PST, SPDT terminal). This signals to the control system that the guard is in a safe position, allowing machine operation.

When the guard is opened, the lever arm is released, causing the contacts to switch state. This action should immediately stop or prevent the start of hazardous machine functions, ensuring operator safety.

Normal Operation Sequence:

  1. Guard Closed: Lever arm actuated, safety circuit closed (or open, depending on specific wiring and safety logic). Machine operation permitted.
  2. Guard Opened: Lever arm released, safety circuit opened (or closed). Machine operation interrupted or prevented.

6. Pangropéa

Regular maintenance ensures the longevity and reliable operation of the safety switch.

  • Inspeksi Visual: Periodically inspect the switch for any signs of physical damage, corrosion, or wear on the lever arm and roller.
  • beberesih: Keep the switch free from dust, dirt, and debris. Use a soft, dry cloth for cleaning. Avoid abrasive cleaners or solvents.
  • Pariksa Fungsional: Regularly test the switch's operation by opening and closing the guard to confirm it correctly interrupts or prevents machine operation.
  • Pariksa sambungan: Ensure all electrical connections remain secure and free from corrosion.

If any damage or malfunction is detected, replace the switch immediately. Do not attempt to repair the safety switch.

7. Cara ngungkulan

This section addresses common issues you might encounter with the NZ1HS-3131-M safety switch.

MasalahMungkin Cukang lantarananaSolusi
Switch does not actuate when guard closes.Incorrect alignment of switch or guard; damaged lever arm.Adjust switch or guard position. Inspect and replace if lever arm is damaged.
Machine does not stop when guard opens.Faulty wiring; damaged switch contacts; bypass of safety circuit.Check wiring for proper connection and integrity. Test switch contacts. Ensure no unauthorized bypasses are present. Replace switch if faulty.
Operasi intermittent.Loose connections; excessive vibration; wear on mechanical parts.Tighten all electrical connections. Secure switch mounting. Inspect for wear and replace if necessary.

If troubleshooting steps do not resolve the issue, contact a qualified technician or EUCHNER support.

8. Spésifikasi

Technical specifications for the EUCHNER NZ1HS-3131-M Safety Switch:

FiturRincian
Nomer modélNZ1HS-3131-M
Modeu OperasiHIRUP
Actuating ElementLever Arm with Steel Roller
Insulasi dipeunteun Voltage250 V
Dipeunteun Voltage230V AC / 24V DC
Peunteun ayeuna4 Amps (Thermal Rated Current)
Ngalihkeun Arus1 mA @ 24V DC
Tipe Kontak4PST
TerminalSPDT
SambunganM20 x 1.5
Connection Cross-Section0.34 ... 1.5 mm2
Peunteun Protection InternasionalIP54
Ukuran produk (L x W x H)0.31 x 0.31 x 0.28 inci
Item Beurat2 pon
BahanSteel (Contact Material)

9. Garansi jeung Rojongan

Information regarding product warranty and customer support is typically provided with the product packaging or available on the manufacturer's official website. Please refer to EUCHNER's official documentation or website for details on warranty terms, technical support, and service options.

Dokumén Patali - NZ1HS-3131-M

Praview EUCHNER RPS-M-E-3131SC175M Rope Pull Switch | Emergency Stop Safety
Discover the EUCHNER RPS-M-E-3131SC175M rope pull switch. Features include a pull-to-reset button, pre-failure monitoring, metal housing, and compliance with EN ISO 13850. Ideal for industrial safety applications.
Praview EUCHNER SGP-TW-1E-2131AC-M Safety Switch - Technical Specifications and Accessories
spésifikasi teknis lengkep, gambar dimensi, sambungan examples, ordering information, and accessories for the EUCHNER SGP-TW-1E-2131AC-M safety switch.
Praview EUCHNER N01R550-MC1526 Precision Single Limit Switch - Datasheet
Technical datasheet for the EUCHNER N01R550-MC1526 precision single limit switch. Features include a roller plunger, M12 plug connector, stainless steel plunger, and IP67 protection. Details dimensional drawings, connection examples, electrical specifications, and ordering information.
Praview EUCHNER ZSB100570: 3-Stage Illuminated Pushbutton with Cable
spésifikasi teknis lengkep, gambar dimensi, sambungan examples, and ordering data for the EUCHNER ZSB100570 3-stage illuminated pushbutton with cable. Features include housing G3, 7m coiled cable, and +/- buttons for industrial control applications.
Praview RIEGEL TP/GP-AC Bolt for Safety Switches | EUCHNER
Detailed technical specifications and ordering information for the EUCHNER RIEGEL TP/GP-AC bolt, a steel bolt accessory for GP and TP safety switches, featuring a lockout bar and robust construction.
Praview EUCHNER CMS-R-BZB-SC Safety Magnetic Proximity Switch | Technical Data & Specifications
spésifikasi teknis lengkep, gambar dimensi, sambungan examples, and ordering information for the EUCHNER CMS-R-BZB-SC safety magnetic proximity switch (Order no. 100753).