This manual provides detailed instructions for the installation, operation, and maintenance of your myTouchSmart 25055 In-Wall Digital Countdown Timer. This device is designed to automate indoor and outdoor lighting, fans, or other devices, offering convenience and energy savings. Please read this manual thoroughly before installation and use to ensure proper functionality and safety.
Émbaran Kasalametan penting
- PERHATOSAN: Risk of Electric Shock. Installation requires working with 120V AC wiring. Always turn off power at the circuit breaker or fuse box before installation.
- Alat ieu dimaksudkeun pikeun pamakéan jero rohangan wungkul.
- A neutral wire is WAJIB for proper installation and operation. If you are unsure, consult a qualified electrician.
- Do not exceed the electrical ratings: 120VAC 60 Hz, 15A General/Resistive, 1200W Tungsten, 1200VA Ballast, ½ HP.
- Pastikeun sadaya sambungan kabel aman sareng insulated leres.
- Baca sakabeh parentah lengkep sateuacan dimimitian instalasi.
Eusi pakét
- myTouchSmart 25055 In-Wall Digital Countdown Timer
- Interchangeable White and Light Almond Switch Covers
- Manual pangguna (dokumén ieu)
Note: A wall plate is not included and must be purchased separately.
Parentah instalasi
- Pareuman Daya: Locate the circuit breaker or fuse that supplies power to the switch you are replacing. Turn it OFF. Verify power is off by attempting to turn on the light or device controlled by the switch.
- Hapus saklar anu aya: Taliti miceun plat témbok jeung unscrew switch aya ti kotak témbok. Pegatkeun sambungan kabel tina switch heubeul.
- Identipikasi Kawat: Identify the LINE (hot), LOAD, NEUTRAL, and GROUND wires. A neutral wire is WAJIB for this timer. If you do not have a neutral wire, consult a qualified electrician.
- Pasangkeun Timer: Connect the wires to the myTouchSmart 25055 timer using the screw terminals as shown in the diagram below. Ensure all connections are tight and secure.
- LINE Wire: Connect to the terminal labeled "Line".
- Beban Kawat: Connect to the terminal labeled "Load".
- NEUTRAL Wire: Connect to the terminal labeled "Neutral".
- GROUND Kawat: Connect to the terminal labeled "Ground".
- Pasang Timer: Gently push the wired timer into the wall box. Secure it with the provided screws.
- Pasang Plat Tembok: Attach your existing or a new wall plate (not included) over the timer.
- Mulangkeun Daya: Hurungkeun kakuatan deui ON di circuit breaker atawa kotak sekering.

Figure 1: Wiring Diagram. This image illustrates the correct connection points for the Line, Load, Neutral, and Ground wires on the back of the myTouchSmart 25055 timer module.
The timer includes interchangeable white and light almond switch covers to match your decor. To change the switch cover, carefully pry off the existing cover and snap on the desired color.
Operasi
Netepkeun Waktos Ayeuna
- Pencét éta JAM tombol pikeun asup kana mode setelan waktos.
- Ngagunakeun éta UP (▲) jeung TURUN (▼) arrow buttons to adjust the hour and minute. The time will scroll.
- Pencét éta JAM tombol deui pikeun ngonfirmasi tur kaluar mode setelan waktos.
Ngagunakeun Program Preset
The myTouchSmart 25055 timer features three preset buttons for common scheduling needs:
- EVENING (5pm-12am): Activates the connected device from 5:00 PM to 12:00 AM.
- MORNING (5am-8am): Activates the connected device from 5:00 AM to 8:00 AM.
- ALL NIGHT (6pm-6am): Activates the connected device from 6:00 PM to 6:00 AM.
To activate a preset program, simply press the corresponding button (e.g., PETI, Isuk-isuk, ALL NIGHT). The blue LED indicator next to the button will illuminate to show it is active.
Custom Countdown Function
The COUNTDOWN button allows you to set a custom countdown timer for up to 24 hours.
- Pencét éta COUNTDOWN kancing. Pintonan bakal nunjukkeun "00:00".
- Ngagunakeun éta UP (▲) jeung TURUN (▼) arrow buttons to set the desired countdown duration (up to 24 hours).
- Pencét éta COUNTDOWN button again to start the countdown. The connected device will turn ON for the set duration and then turn OFF.
Manual ON/OFF Override
You can manually turn the connected device ON or OFF at any time, overriding any active program.
- Pencét éta ON button to manually turn the device ON.
- Pencét éta Pareum button to manually turn the device OFF.

Figure 2: Simple Setup and Operation. This image highlights the scroll buttons for setting the current time and the preset buttons for activating schedules.
Fitur
- Digital tampilan: Clear digital display for time and countdown settings.
- Program Praet: Three convenient preset programs (Evening, Morning, All Night) and a Custom Countdown.
- Manual Override: Dedicated ON/OFF buttons for instant manual control.
- Indikator LED: Blue LED lights indicate active programs.
- Kasaluyuan lega: Works with LED, CFL, Incandescent, and Halogen bulbs, including dimmable LED and CFL.
- Batré Cadangan: Maintains settings during power outages.
- Pamasangan Gampang: Screw terminal installation for efficient wiring.
- Pilihan Estetika: Includes interchangeable white and light almond switch covers.

Figure 3: Product Applications. This image demonstrates that the timer can control various devices such as indoor/outdoor lights, ceiling fans, and exhaust fans.
Pangropéa
- Clean the timer's surface with a soft, dry cloth. Do not use abrasive cleaners, solvents, or harsh chemicals.
- The internal backup battery is designed for long-term use and typically does not require replacement.
Pamérésan masalah
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Timer teu hurung. | No power to the switch box; incorrect wiring; neutral wire not connected. | Check circuit breaker. Verify wiring connections (Line, Load, Neutral, Ground). Ensure neutral wire is connected. |
| Connected device does not turn ON/OFF as scheduled. | Incorrect current time setting; program not activated; device malfunction. | Verify current time is set correctly. Ensure the desired program (Evening, Morning, All Night, Countdown) is active (blue LED). Test the connected device manually. |
| Tampilan kosong atanapi kedip-kedip. | Low power; internal issue. | Ensure stable power supply. If problem persists, turn off power at the breaker for 5 minutes, then restore. If still unresolved, contact customer support. |
| Tombol-tombol henteu ngaréspon. | Gangguan parangkat lunak samentawis; karusakan fisik. | Turn off power at the breaker for 5 minutes, then restore. If still unresponsive, contact customer support. |
spésifikasi
- model: 25055
- Peunteun Listrik: 120VAC, 60 Hz
- Beban Max: 15A General/Resistive, 1200W Tungsten, 1200VA Ballast, ½ HP
- Ukuran produk: 2 "D x 4.5" W x 6" H
- Timer Module Dimensions: Approximately 1.75" (4.45cm) width x 4.25" (10.8cm) height
- Bahan: palastik
- warna: White (with interchangeable Light Almond option)
- Sertifikasi: UL Didaptarkeun
- Kawat nétral: Dibutuhkeun
- Batré Cadangan: NiMH (internal)

Figure 4: Timer Module Dimensions. This image provides the physical measurements of the timer module for installation reference.
Garansi sareng Rojongan
Kanggo inpormasi garansi atanapi dukungan téknis, mangga tingal resmi produsén websitus atanapi ngahubungan departemén layanan palanggan maranéhna. Simpen resi pameseran anjeun pikeun klaim jaminan.