1. Bubuka
This manual provides essential information for the safe and effective operation of your OWON SDS6062 Digital Storage Oscilloscope. Please read this manual thoroughly before using the device to ensure proper setup, operation, and maintenance. The SDS6062 is a 2-channel oscilloscope featuring a 60 MHz bandwidth, 500 MS/s sample rate, and a 10M record length, designed for precise electrical signal analysis.
2. Émbaran Kasalametan
Always observe the following safety precautions to prevent injury and avoid damage to the instrument or any connected products. Read these instructions carefully before operation.
- Sumber Daya: Use only the power adapter supplied with the instrument. Ensure the voltage cocog catu daya lokal Anjeun.
- Grounding: The oscilloscope must be properly grounded to prevent electric shock.
- Kasalametan Probe: Do not connect the probe ground lead to a point where a voltage greater than 30V RMS or 42.4V peak is present.
- Lingkungan: Operate the device in a well-ventilated area, away from moisture, dust, and direct sunlight. Avoid operating in explosive atmospheres.
- Pangropéa: Rujukkeun sadaya jasa ka petugas jasa anu mumpuni. Ulah nyobian ngalereskeun unit ieu nyalira.
3. Eusi Paket
Verify that all items listed below are present in your package. If any items are missing or damaged, contact your supplier.
- OWON SDS6062 Digital Storage Oscilloscope Unit
- 2 x Probe Osiloskop
- 1 x Kabel Listrik
- 1 x Probe Adjust Pen
- 1 x Kabel Data USB
- 1 x Software CD
- 1 x Buku Panduan Pamaké (dokumén ieu)
4. Produk Langkungview
The OWON SDS6062 is a compact and powerful digital storage oscilloscope. It features an 8-inch (800x600) color TFT-LCD screen for clear waveform display and an intuitive control panel for easy operation. Key features include its 60 MHz bandwidth, 500 MS/s real-time sample rate, and 10M record length, making it suitable for a wide range of applications.

Gambar 4.1: Hareupeun view of the OWON SDS6062 Digital Storage Oscilloscope, showing the display, control knobs, and function buttons.
4.1 Kadali Panel hareup
The front panel includes the main display, vertical controls (VOLTS/DIV, position), horizontal controls (SEC/DIV, position), trigger controls, and various function buttons for menu navigation, measurement, and utility settings.
4.2 Sambungan Panel Rear
The rear panel provides connectivity options including the power input, USB host and device ports, LAN port for network connectivity, and a VGA port for external display output.
5. Setélan
Follow these steps to set up your OWON SDS6062 oscilloscope for initial use.
5.1 Nyambungkeun Daya
- Ensure the oscilloscope is turned off.
- Connect the supplied power cord to the power input on the rear panel of the oscilloscope.
- Colokkeun tungtung kabel listrik anu sanés ka stop kontak listrik AC anu dibumikeun.
5.2 Nyambungkeun Probe
- Align the BNC connector of the probe with the CH1 or CH2 input on the front panel.
- Push and twist the connector clockwise until it locks into place.
- Attach the probe ground clip to the ground terminal of the circuit under test.
- Set the probe attenuation switch (e.g., 1X or 10X) to match the setting on the oscilloscope's input channel menu.
5.3 Mimiti Power-On
- Pencét tombol daya anu aya dina panel hareup.
- The oscilloscope will perform a self-test and display the startup screen.
- After startup, it is recommended to perform a probe compensation adjustment (refer to Section 7.3).
6. Ngoperasikeun Osiloskop
This section covers basic operation and common functions of the SDS6062.
6.1 Pangukuran Dasar
To display a signal:
- Connect a signal source to CH1 or CH2 using a probe.
- Pencét éta AUTOSET button. The oscilloscope will automatically adjust vertical, horizontal, and trigger settings to display a stable waveform.
- Saluyukeun VOLTS/DIV knob to change the vertical scale (voltage per divisi).
- Saluyukeun SEC/DIV knob to change the horizontal scale (time per division).
- Use the vertical and horizontal POSISI knobs to move the waveform on the screen.
6.2 Sistem Pemicu
Sistem pemicu ngastabilkeun bentuk gelombang anu diulang-ulang sareng ngarékam kajadian single-shot.
- Tingkat pemicu: Ngagunakeun éta TRIGGER LEVEL tombol pikeun nyetel voltage level at which the trigger occurs.
- Modeu pemicu: Access the trigger menu to select modes like Edge, Pulse, Video, or Slope.
- Sumber pemicu: Select the input channel (CH1, CH2, EXT, AC Line) that will be used for triggering.
6.3 Fungsi Pangukuran
The SDS6062 offers various automatic measurement functions.
- Pencét éta UKURAN button to display the measurement menu.
- Select desired measurements such as Vpp, Vmax, Vmin, Freq, Period, Rise Time, etc.
6.4 Connectivity (LAN and VGA)
- LAN: Connect an Ethernet cable to the LAN port on the rear panel to connect the oscilloscope to a network. This allows for remote control and data transfer using compatible software.
- VGA: Use the VGA port to connect an external monitor or projector for larger display of waveforms, useful for presentations or collaborative work.
7. Pangropéa
Pangropéa anu leres mastikeun umur panjang sareng akurasi osiloskop anjeun.
7.1 beberesih
Bersihkeun alat sacara rutin nganggo lap anu lemesamp cloth. Do not use abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is powered off and unplugged before cleaning.
7.2 Panyimpenan
When not in use, store the oscilloscope in a dry, dust-free environment, away from extreme temperatures and direct sunlight. Use the original packaging or a suitable carrying case for protection during transport.
7.3 Probe Compensation Adjustment
Probe compensation should be adjusted to match the oscilloscope's input characteristics. This ensures accurate measurements.
- Connect the probe to CH1 and attach the probe tip to the probe compensation output (usually a square wave test point on the front panel).
- Attach the probe ground clip to the ground terminal.
- Pencét AUTOSET.
- Use the supplied probe adjust pen to turn the trimmer screw on the probe until the square wave displayed on the screen has flat top and bottom edges (no overshoot or undershoot).
8. Cara ngungkulan
Bagian ieu nyayogikeun solusi pikeun masalah umum anu anjeun tiasa patepang.
- Henteu aya tampilan: Check power connection, ensure the power button is pressed. Adjust screen brightness if necessary.
- No Waveform: Verify probe connection to the input channel and the circuit under test. Ensure the signal source is active. Press AUTOSET. Check vertical and horizontal scale settings.
- Unstable Waveform: Adjust the trigger level. Check trigger mode and source settings. Ensure the signal is within the oscilloscope's bandwidth.
- Pangukuran anu teu akurat: Perform probe compensation adjustment (Section 7.3). Ensure probe attenuation settings match the oscilloscope.
- Alat Teu Ngabales: Try restarting the oscilloscope. If the issue persists, contact technical support.
9. Spésifikasi
Technical specifications for the OWON SDS6062 Digital Storage Oscilloscope.
| Parameter | Spésifikasi |
|---|---|
| Nomer modél | SDS6062 |
| Bandwidth | 60 MHz |
| Saluran | 2 + 1 (External Trigger) |
| Sample Rate (Real-time) | 500 MS/s |
| Rékam Panjang | 10M points |
| tampilan | 8-inch Color TFT-LCD (800x600) |
| Panganteur | USB Host, USB Device, LAN, VGA |
| AutoScale Function | Sumuhun |
| Produsén | OWON |
10. Garansi jeung Rojongan
OWON products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official OWON website. For technical support, troubleshooting assistance, or service inquiries, please contact your local OWON distributor or the OWON customer service department. Keep your purchase receipt as proof of purchase for warranty claims.