deleyCON MK899

Buku Panduan Pangguna Detektor Gerakan Infrabeureum deleyCON MK899

Modél: MK899

1. Bubuka

This manual provides detailed instructions for the installation, operation, and maintenance of your deleyCON MK899 Infrared Motion Detector. This device is designed for indoor use to automatically control lighting based on detected movement and ambient light levels. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Parentah Kasalametan

  • Pamasangan kedah dilakukeun ku tukang listrik anu mumpuni luyu sareng kode sareng peraturan listrik lokal.
  • Disconnect power at the circuit breaker before installing or servicing the device.
  • Do not install in areas with high humidity or direct water exposure (IP20 rating: suitable for indoor, dry environments only).
  • Mastikeun suplai voltage matches the specifications of the motion detector.
  • Do not open the device housing or attempt to modify the internal components.

3. Eusi Paket

Pastikeun yén sadaya komponén aya dina bungkusan:

  • 1x deleyCON Infrared Motion Detector (MK899)
  • 1 x Manual Pamaké
  • 2x Screws with dowels for mounting

4. Produk Langkungview

The deleyCON MK899 motion detector features a compact design for ceiling surface mounting. It includes adjustable settings for light duration and ambient light sensitivity.

Close-up of deleyCON MK899 motion detector showing sensor, TIME and LUX adjustment dials, and control LED.

Gambar 1: Pahareup-hareup view of the motion detector's sensor, adjustment dials, and control LED. The dials are labeled 'TIME' for light duration and 'LUX' for light sensitivity.

  1. Sénsor: Detects infrared radiation from moving objects.
  2. TIME Adjustment Dial: Controls the duration the light remains on after motion detection.
  3. LUX Adjustment Dial: Sets the ambient light threshold for activation.
  4. Kontrol Lamp (LED): Indicates motion detection and operational status.

5. Spésifikasi

FiturSpésifikasi
Nomer modélMK899
merekdeleyCON
Ukuran produk (L x W x H)11.5 x 11.5 x 5.8 cm
Beurat161 gram
WarnaBodas
Jinis kakuatanAC (Arus bolak-balik)
Tipe PamasanganSurface Mount (Ceiling)
Sudut deteksi360°
Rentang deteksi maksimum6 méter
Kelas panyalindunganIP20 (Pamakéan di jero rohangan)
Adjustable Light Duration (TIME)10 detik nepi ka 7 menit
Adjustable Ambient Brightness (LUX)Sumuhun
Alat nu cocogLights (Lamps, LEDs)
Kisaran Suhu Operasi60 Degrees Celsius (Note: This value seems unusually high for an operating range. Please refer to product packaging for exact operating temperature limits.)

6. Setup jeung Instalasi

The deleyCON MK899 is designed for surface mounting on ceilings. Ensure power is disconnected before proceeding.

6.1 Pasang Alat

  1. Separate the mounting plate from the main unit by twisting or unlatching as indicated by the device design.
  2. Position the mounting plate on the desired ceiling location. Mark the drilling points through the holes on the plate.
  3. Drill holes at the marked positions and insert the provided dowels.
  4. Secure the mounting plate to the ceiling using the provided screws.
Tukangeun view of the deleyCON MK899 motion detector showing the detachable mounting plate and wiring terminals.

Gambar 2: Tukangeun view of the motion detector, illustrating the detachable mounting plate and the internal wiring terminals.

6.2 Diagram Wiring

Follow the wiring diagram carefully. Incorrect wiring can damage the device or connected lights.

Wiring diagram for the deleyCON MK899 motion detector, showing connections for Live (L), Neutral (N), and Load (A) to a light bulb.

Gambar 3: Wiring schematic for the motion detector. Connect the Live (L) and Neutral (N) input wires, and the Load (A) output wire to the light fixture. The diagram shows L (Phase/Hot), N (Neutral/Ground), and A (Consumer/Lamp).

  • Connect the Live (L) wire from your power supply to the 'IN~ L' terminal.
  • Connect the Neutral (N) wire from your power supply to the 'IN~ N' terminal.
  • Connect the Live wire of your light fixture (Load) to the 'OUT~ LOAD' terminal.
  • Connect the Neutral wire of your light fixture to the 'IN~ N' terminal (shared with incoming neutral).

After wiring, attach the main unit to the mounting plate, ensuring it is securely fastened.

7. Parentah Operasi

Once installed and powered, the motion detector will enter a warm-up period (typically 30-60 seconds) during which it may activate randomly. After this, it will be ready for operation and adjustment.

7.1 Adjusting Light Duration (TIME)

The 'TIME' dial controls how long the connected light remains on after motion is detected and the detection zone is clear. Rotate the dial to set the desired duration:

  • '-' (Minimum): Kurang leuwih 10 detik.
  • '+' (Maximum): Kurang leuwih 7 menit.

7.2 Adjusting Ambient Light Sensitivity (LUX)

The 'LUX' dial determines the ambient light level at which the motion detector will activate. This prevents the light from turning on during daylight hours when not needed.

  • '☼' (Sun Symbol - Maximum): The detector will activate regardless of ambient light (day and night).
  • '☽' (Moon Symbol - Minimum): The detector will only activate in very low light conditions (dusk/night).

Adjust the dial to your preferred setting. For testing, set it to the 'Sun' symbol to ensure functionality during daylight.

7.3 Wewengkon Deteksi

The deleyCON MK899 offers a 360° detection angle with a maximum range of 6 meters, ideal for comprehensive coverage in indoor spaces.

Illustration showing the 360-degree detection area and 6-meter range of the motion detector.

Gambar 4: Visual representation of the motion detector's 360° detection angle and maximum 6-meter range, suitable for indoor environments.

8. Pangropéa

The deleyCON MK899 motion detector requires minimal maintenance.

  • beberesih: Ngusap alat ku kaén anu lemes sareng garing. Ulah make cleaners abrasive atawa pangleyur.
  • Pamariksaan: Periodically check for any visible damage or loose connections.
  • The device contains no user-serviceable parts. Do not attempt to disassemble it.

9. Cara ngungkulan

If you encounter issues with your motion detector, refer to the following common problems and solutions:

MasalahMungkin Cukang lantarananaSolusi
Lampuna teu hurung nalika aya gerakan nu kadeteksi.
  • Incorrect LUX setting (too high).
  • Taya kakuatan ka alat.
  • Wiring lepat.
  • Gerakan di luar rentang deteksi.
  • Adjust LUX dial towards the 'Moon' symbol.
  • Pariksa circuit breaker sarta sambungan kakuatan.
  • Verify wiring according to the diagram.
  • Ensure motion occurs within 6m range and 360° angle.
Lampu terus hurung.
  • Gerakan anu konstan di daérah deteksi.
  • Incorrect TIME setting (too long).
  • Gagalna alat.
  • Ensure no continuous movement or heat sources (e.g., heating vents) are within the detection zone.
  • Adjust TIME dial towards the '-' symbol.
  • If problem persists, disconnect power and consult a professional.
Light turns on too frequently or randomly.
  • LUX setting too sensitive.
  • Small animals or objects causing detection.
  • Drafts or temperature fluctuations.
  • Adjust LUX dial towards the 'Sun' symbol.
  • Relocate the detector or adjust its position to avoid unwanted triggers.
  • Ensure stable environmental conditions.

10. Garansi jeung Rojongan

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official deleyCON websitus. Simpen bukti pameseran anjeun pikeun klaim garansi.

Dokumén Patali - MK899

Praview deleyCON HDMI Wanddose 4K Benutzerhandbuch
Umfassendes Benutzerhandbuch für die deleyCON HDMI Wanddose 4K. Pamasangan Enthält, Tanggal Téknologi, Sicherheitshinweise und Informationen zur Produktkonformität Für Modelle kalawan MK3164.
Praview deleyCON Mini Infrarød Bevægelsesdetektor Quickstart Guide
Denne quickstart pituduh giver en oversigt leuwih deleyCON urang mini infrarøde bevægelsesdetektor, installationsvejledning inklusif, sikkerhedsinstruktioner og tekniske specifikationer. Lær hvordan du korrekt installerer og bruger din bevægelsesdetektor til ydeevne optimal.
Praview deleyCON Audio Cinch Kabel: Benutzerhandbuch und technische Informationen
Umfassendes Benutzerhandbuch für deleyCON Audio Cinch Kabel (RCA-Kabel). Erfahren Sie mehr über Produktdetails, technische Spezifikationen, Sicherheitshinweise und Konformitätserklärungen für Modelle wie MK4085. Enthält Informationen zur Instalasi, Verwendung und Entsorgung.