Apera Instruments MP511

Apera Instruments MP511 Benchtop pH Meter

Manual pamaké

1. Bubuka

This manual provides instructions for the proper setup, operation, and maintenance of the Apera Instruments MP511 Benchtop pH Meter. The MP511 is designed for accurate pH measurements with a range of -2.00 to 19.99 pH and an accuracy of ±0.01 pH. It features automatic temperature compensation (ATC), auto-calibration with buffer recognition, and advanced digital filtering technology for improved response time and accuracy. The meter also includes GLP standard data management, storage for 500 data sets, and RS232 data output.

2. Eusi Paket

Pastikeun yén sadaya komponén aya nalika ngabongkar:

  • MP511 Benchtop pH Meter Unit
  • 3-in-1 Combination pH Electrode
  • Flexible Electrode Holder
  • RS232 Software (typically on a CD or available for download)
  • Adaptor kakuatan
  • pH Buffer Solutions (e.g., pH 4.00, 7.00, 10.01)
  • Instruksi Manual

3. Setélan

  1. Assemble the Electrode Holder: Attach the flexible electrode holder to the meter base. Ensure it is securely fastened to provide stable support for the electrode.
  2. Connect the Electrode: Plug the BNC connector of the 3-in-1 combination pH electrode into the pH/mV input port on the back of the meter. If a separate temperature probe is used, connect it to the TEMP port.
  3. Sambungkeun Kakuatan: Plug the DC 9V power adapter into the DC 9V port on the back of the meter and then into a standard electrical outlet.
  4. Penempatan awal: Place the electrode in its storage solution or a beaker of distilled water when not in use.
Apera Instruments MP511 Benchtop pH Meter with electrode in a beaker

Gambar 3.1: The Apera Instruments MP511 Benchtop pH Meter with its electrode immersed in a sample solution within a beaker, demonstrating a typical setup for pH measurement. The flexible electrode holder is visible, supporting the electrode.

4. Operasi

  1. Hurungkeun/Pareuman: Pencét éta ON/OFF tombol pikeun ngaktipkeun atanapi mareuman méter.
  2. Pilihan Mode: Pencét éta MODÉ button to cycle through different measurement modes (pH, mV, temperature).
  3. Pilihan Unit: Pencét éta UNIT button to change temperature units between °C and °F.
  4. Data Storage/Recall: Ngagunakeun éta M+/RM button to store current readings or recall previously stored data.
  5. Confirm/Enter: The Asupkeun button is used to confirm selections or enter calibration mode.
Close-up of Apera Instruments MP511 Benchtop pH Meter display and control buttons

Gambar 4.1: A lengkep view of the MP511 meter's LCD display and control panel, showing the CAL, ON/OFF, M+/RM, MODE, ENTER, and UNIT buttons. The display shows pH and temperature readings.

5. Kalibrasi

Regular calibration is essential for accurate pH measurements. The MP511 features automatic calibration with buffer recognition.

  1. Nyiapkeun Buffer: Ensure you have fresh pH buffer solutions (e.g., pH 4.00, 7.00, 10.01) at room temperature.
  2. Éléktroda Bilas: Rinse the electrode thoroughly with distilled water and gently blot dry with a lint-free tissue.
  3. Lebetkeun Modeu Kalibrasi: With the meter powered on and in pH mode, press the KAL button. The display will indicate calibration mode.
  4. First Buffer Calibration: Immerse the electrode into the first buffer solution (e.g., pH 7.00). The meter will automatically recognize the buffer and stabilize. Press Asupkeun pikeun mastikeun.
  5. Subsequent Buffer Calibration: Rinse the electrode again. Immerse it into the next buffer solution (e.g., pH 4.00 or pH 10.01). The meter will recognize and stabilize. Press Asupkeun to confirm. Repeat for additional buffer points as needed.
  6. Exit Calibration: After completing all desired calibration points, the meter will automatically return to measurement mode or prompt to save calibration.

6. Modeu pangukuran

The MP511 offers three distinct measurement modes:

  • Stable Measurement Display Mode: Displays the pH reading once it has stabilized. This is the standard mode for most measurements.
  • Timing Measuring Mode: Allows for measurements at set intervals, useful for monitoring changes over time.
  • Modeu pangukuran kontinyu: Provides real-time, continuous pH readings, suitable for dynamic processes.

Refer to the detailed instructions in the full manual for specific steps on how to select and configure each measurement mode.

7. Manajemén Data

The MP511 incorporates GLP (Good Laboratory Practice) standard data management features:

  • Panyimpenan Data: The meter can store up to 500 sets of measurement data.
  • Metode Panyimpenan: Data can be stored manually or automatically at user-defined timing intervals.
  • Kaluaran Data: An RS232 port is provided for connecting the meter to a computer to transfer stored data using the included software.
Tukangeun view of Apera Instruments MP511 Benchtop pH Meter showing connectivity ports

Gambar 7.1: The rear panel of the MP511 meter, displaying the REF, pH/mV, TEMP, RS232, and DC 9V input ports. The RS232 port facilitates data transfer to a computer.

8. Pangropéa

Proper maintenance ensures the longevity and accuracy of your pH meter.

  • Perawatan éléktroda:
    • Always keep the electrode bulb immersed in storage solution when not in use. Never store it dry.
    • Rinse the electrode with distilled water before and after each measurement.
    • Clean the electrode regularly according to the electrode's specific cleaning instructions, especially if readings become sluggish or inaccurate.
  • Meter Cleaning: The MP511 meter unit meets IP54 waterproof and dustproof standards. Clean the exterior with a damp lawon. Ulah make bahan kimia kasar atawa bahan abrasive.
  • Sumber Daya: The meter is battery-powered (though also uses a DC 9V adapter). Ensure the power adapter is used correctly. If using internal batteries, replace them as needed.

9. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Bacaan teu stabilÉléktroda kotor; gelembung hawa; s teu cekapample volume; electromagnetic interferenceClean electrode; gently tap electrode to remove bubbles; ensure adequate sample; move meter away from interference sources
Kasalahan kalibrasiExpired or contaminated buffer solutions; dirty electrode; incorrect buffer sequenceUse fresh buffer solutions; clean electrode; ensure correct buffer order (e.g., 7.00 first)
No display/Power issuePower adapter not connected; faulty power adapter; internal battery depletionCheck power connection; try a different outlet; replace internal batteries if applicable
waktos respon lalaunanElectrode dry or contaminated; old electrodeRehydrate electrode in storage solution; clean electrode; consider electrode replacement

10. Spésifikasi

ParameterNilai
Nomer modélAI511 (MP511)
Rentang pH-2.00 ka 19.99 pH
Akurasi pH± 0.01 pH
Santunan SuhuAutomatic (ATC)
KalibrasiAuto Calibration with buffer recognition
Panyimpenan Data500 data sets (manual/auto timing storage)
KonektipitasRS232
Tipe tampilanLCD sareng lampu tukang biru
Protéksi Ingress (IP) PeunteunIP54 (Tahan cai sareng Debu)
Dimensi produk19.05 x 16 x 7.11 cm
Beurat produk878.84 g
Sumber DayaBattery Powered (with DC 9V adapter)
ProdusénShanghai Sanxin Instrumentation

11. Garansi jeung Rojongan

For warranty information, technical support, or service inquiries, please contact Apera Instruments directly through their official websitus atanapi saluran layanan palanggan. Simpen resi pameseran anjeun salaku bukti pameseran.

Dokumén Patali - MP511

Praview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instruction manual for the Apera PH700 Benchtop pH Meter, covering features, specifications, operation, calibration, maintenance, and troubleshooting.
Praview Apera PH700 Benchtop pH Meter Instruction Manual
Comprehensive instructions for operating, calibrating, and maintaining the Apera PH700 Benchtop pH Meter. It covers technical specifications, instrument description, measurement procedures for pH and ORP, parameter settings, electrode care, and troubleshooting.
Praview PH60Z-HT Smart pH Méter Manual Pamaké - Apera Instrumen
Manual pamaké pikeun Apera Instruments PH60Z-HT Smart pH Méter, ngajéntrékeun fitur, operasi, kalibrasi, pangropéa, sareng ngungkulan pikeun suhu luhur sareng solusi caustic.
Praview Apera PH60Z-MS Smart pH Meter User Manual: Small-Volume Measurement Guide
Comprehensive user manual for the Apera PH60Z-MS Smart pH Meter, detailing setup, calibration, measurement, maintenance, troubleshooting, and technical specifications for small-volume pH testing.
Praview PH60-VS pH Meter for Viscous Samples User Manual | Apera Instruments
Comprehensive user manual for the Apera Instruments PH60-VS pH Meter, designed for measuring pH in viscous samples like cosmetics, coatings, and honey. Includes setup, calibration, measurement, maintenance, and troubleshooting.
Praview Apera EC20 Pocket Conductivity Tester: Instruksi Manual & Guide
Instruksi manual komprehensif pikeun Apera EC20 Pocket Conductivity Tester. Diajar ngeunaan setelan, kalibrasi, pangukuran konduktivitas, spésifikasi téknis, sareng inpormasi jaminan.