Bubuka
This manual provides essential information for the proper installation, operation, and maintenance of your Watts LF26A Water Pressure Regulator Valve. Please read this manual thoroughly before installation and keep it for future reference. This valve is designed to reduce incoming water pressure to a safe and functional level for residential and light commercial applications, protecting plumbing systems and fixtures from high pressure damage.
Produk Leuwihview jeung Fitur
The Watts LF26A is a high-quality water pressure regulator valve engineered for reliable performance and durability. Key features include:
- Lead-Free Brass Body: Constructed from durable lead-free brass for safe potable water applications.
- Rentang Tekanan anu tiasa disaluyukeun: Allows for precise adjustment of outlet pressure from 1 to 25 psi.
- FIP Connections: Features 3/8 inch Female Iron Pipe (FIP) connections for easy installation.
- NSF disatujuan: Certified to meet NSF standards for water quality and safety.
- Desain kompak: Efficient design with dimensions of 2.3 x 2.3 x 5.1 inches.
- Tekanan Maksimum Tinggi: Capable of handling maximum inlet pressures up to 300 psi.
- Peunteun Suhu: Suitable for water temperatures up to 140 degrees F.

Figure 1: Watts LF26A Water Pressure Regulator Valve. This image displays the valve's brass body, the FIP threaded connections on the side, and the pressure adjustment screw located at the top of the brown housing.
Émbaran Kasalametan
Salawasna perhatoskeun tindakan pencegahan kaamanan ieu nalika pamasangan sareng pangropéa:
- Ensure water supply is shut off and pressure is relieved before beginning any work.
- Anggo alat pelindung pribadi (PPE), sapertos kacamata kaamanan sareng sarung tangan.
- Do not exceed the maximum operating pressure or temperature specified for the valve.
- Upami anjeun henteu yakin kana léngkah naon waé, konsultasi ka tukang ledeng anu mumpuni.
- Comply with all local plumbing codes and regulations.
Pamasangan
Daptar pariksa Pra-Pasang:
- Verify that the valve model (LF26A) and size (3/8 inch) are correct for your application.
- Ensure you have the necessary tools: pipe wrenches, thread sealant (Teflon tape or pipe dope), and a pressure gauge.
- Inspect the valve for any visible damage before installation.
Léngkah-léngkah pamasangan:
- Pareuman suplai cai: Locate the main water shut-off valve for your property and turn it off.
- Sistim solokan: Open a faucet at the lowest point in your system to drain water and relieve pressure.
- Pilih Lokasi: Install the pressure regulator valve in an accessible location, typically after the main shut-off valve and before any branch lines. Ensure there is sufficient space for future maintenance.
- Nyiapkeun sambungan: Apply appropriate thread sealant (Teflon tape or pipe dope) to the male threads of the pipes connecting to the valve.
- Pasang Katup: Orient the valve according to the flow arrow cast on its body. The arrow must point in the direction of water flow. Thread the valve onto the pipes, tightening securely with pipe wrenches. Avoid overtightening.
- Install Pressure Gauge (Recommended): For accurate pressure monitoring, install a pressure gauge downstream of the regulator.
- Mulangkeun suplai cai: Buka klep pareum cai utama lalaunan. Pariksa bocor dina sadaya sambungan.
- Ngabersihan hawa: Open faucets throughout the system to purge air until water flows smoothly.
Operasi
The Watts LF26A valve is factory preset to a nominal pressure. Adjustment may be necessary to achieve the desired system pressure.
Nyaluyukeun Tekanan Outlet:
- Ensure a pressure gauge is installed downstream of the valve for accurate readings.
- Ka naékkeun the outlet pressure, turn the adjustment screw (located on top of the valve) saarah jarum jam.
- Ka ngurangan the outlet pressure, turn the adjustment screw counter-jarum jam.
- Make small adjustments (e.g., quarter turns) and observe the pressure gauge. Allow the system pressure to stabilize after each adjustment.
- Once the desired pressure is set, ensure the locknut (if present) is tightened to secure the setting.
The adjustable pressure range for this model is 1 to 25 psi.
Pangropéa
Regular maintenance helps ensure the longevity and optimal performance of your pressure regulator valve.
- Inspeksi taunan: Annually inspect the valve for any signs of leaks, corrosion, or external damage.
- Verifikasi tekanan: Periodically check the outlet pressure using a pressure gauge to ensure it remains at the desired setting. Fluctuations may indicate a need for adjustment or service.
- beberesih: The exterior of the valve can be wiped clean with a damp cloth. Do not use harsh chemicals. Internal cleaning or servicing should only be performed by a qualified professional.
- Winterization: In areas subject to freezing temperatures, ensure the valve and associated piping are adequately protected from freezing. Drain the system if it will be out of service for an extended period in freezing conditions.
Pamérésan masalah
If you experience issues with your Watts LF26A pressure regulator valve, refer to the following common problems and solutions:
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| No pressure reduction or high outlet pressure. | Valve set too high; debris in valve; worn internal components. | Adjust pressure setting counter-clockwise; flush system; consult professional for repair/replacement. |
| Low or fluctuating outlet pressure. | Valve set too low; insufficient inlet pressure; debris in valve; worn internal components. | Adjust pressure setting clockwise; check main water supply pressure; flush system; consult professional. |
| Water leaking from valve body or connections. | Loose connections; damaged threads; faulty seals/gaskets; cracked valve body. | Tighten connections; re-apply thread sealant; replace seals/gaskets; replace valve if cracked. |
| No water flow through valve. | Valve completely closed; significant debris blockage; incorrect installation (e.g., backward). | Check adjustment setting; flush system; verify flow arrow direction; consult professional. |
For issues not listed or if solutions do not resolve the problem, it is recommended to contact a qualified plumbing professional or Watts customer support.
spésifikasi
| Atribut | Nilai |
|---|---|
| Nomer modél | LF26A |
| Bahan Awak | Timah Free Kuningan |
| Ukuran Inlet | 3/8 inci |
| Ukuran Outlet | 3/8 inci |
| Tipe Sambungan | FIP (Female Iron Pipe) |
| Rentang adjustment tekanan | 1 nepi ka 25 psi |
| Tekanan Inlet Maksimum | 300 psi |
| Suhu maksimum | 140°F (60°C) |
| Ukuran produk (L x W x H) | 2.3 x 2.3 x 5.1 inci |
| Beurat | 1 pon |
| Aplikasi | Cai |
| Sertifikasi | NSF disatujuan |
| Produsén | CAI - WATTS |
Garansi sareng Rojongan
Warranty information for the Watts LF26A Water Pressure Regulator Valve is typically provided with the product packaging or can be obtained directly from the manufacturer, Watts. Please refer to the official Watts website or contact their customer service for detailed warranty terms and conditions.
For technical support, replacement parts, or further assistance, please contact Watts customer service or visit their official website. When contacting support, please have your product model number (LF26A) and purchase details readily available.
Watts Official Websitus: www.watts.com