Watts LFN45B

Watts LFN45B Pressure Reducing Valve User Manual

Model: LFN45B | Brand: Watts

Bubuka

This manual provides essential information for the installation, operation, maintenance, and troubleshooting of the Watts LFN45B Pressure Reducing Valve. This valve is designed for residential and light commercial applications to regulate water pressure effectively and safely.

Produk Leuwihview

Watts LFN45B Pressure Reducing Valve

Figure 1: Watts LFN45B Pressure Reducing Valve. This image displays the bronze-bodied valve with its black adjustment cap and threaded union connections on both sides.

The Watts LFN45B is a compact and versatile pressure reducing valve featuring a bronze body construction. It includes an integrated filter and bypass mechanism. The valve is equipped with NPT union female inlet and female outlet threads for easy installation. It is suitable for water systems with a temperature range of 33 to 180 degrees Fahrenheit and a maximum working pressure of 400 psi. The standard pressure reduction is 50 PSI, adjustable from 25 to 75 psi. A bypass function is incorporated to manage thermal expansion pressure when the inlet pressure exceeds 150 PSI. The valve meets the requirements of ASSE 1003 (ANSI a112.26.2) and IAPMO standards.

Bahan: The valve is constructed from durable materials including Bronze, Copper Alloy, and Stainless Steel for the body and internal components. The seat trim is Thermoplastic, softgoods are Elastomer Disc, and the diaphragm is Reinforced EPDM.

Setup sareng Instalasi

Proper installation is crucial for the optimal performance and longevity of the Watts LFN45B Pressure Reducing Valve. It is recommended that installation be performed by a qualified professional in accordance with local plumbing codes.

Parentah Operasi

The Watts LFN45B valve is factory set to a standard reduced pressure of 50 PSI. This pressure can be adjusted within a range of 25 to 75 psi.

  1. Penyesuaian tekanan: To adjust the outlet pressure, loosen the locknut on the adjustment screw located at the top of the valve.
  2. Ningkatkeun Tekanan: Turn the adjustment screw clockwise to increase the outlet pressure.
  3. Decrease Pressure: Turn the adjustment screw counter-clockwise to decrease the outlet pressure.
  4. Verify Pressure: Use a pressure gauge downstream of the valve to verify the desired pressure setting.
  5. Secure Setting: Once the desired pressure is set, tighten the locknut to secure the adjustment screw in place.
  6. Fungsi Bypass: The bypass function automatically controls thermal expansion pressure until the inlet pressure is above 150 PSI. No manual operation is required for this feature.

Pangropéa

Regular maintenance ensures the continued efficiency and reliability of your pressure reducing valve.

Pamérésan masalah

This section provides guidance for common issues you might encounter with your pressure reducing valve.

MasalahMungkin Cukang lantarananaSolusi
High Downstream PressureValve setting too high; debris in valve; thermal expansion.Adjust pressure setting; clean strainer; install or check expansion tank.
Low Downstream PressureValve setting too low; insufficient inlet pressure; clogged strainer.Adjust pressure setting; check main water supply; clean strainer.
Constant Dripping/LeakingWorn seat or diaphragm; loose connections.Replace seat module or diaphragm; tighten connections.
No Pressure ReductionValve bypass stuck open; internal component failure.Inspect bypass mechanism; consider professional service or replacement.

If issues persist after attempting these solutions, contact a qualified plumbing professional or Watts customer support.

spésifikasi

Nomer modélLFN45B
merekWatt
BahanBronze, Copper, Stainless Steel
Exterior FinishPerunggu, Baja Tahan Karat
Ukuran Sambungan Inlet1 inci
Tipe Sambungan InletNational Pipe Tapered (NPT)
Tipe Sambungan OutletFNPT
Tekanan Operasi Maksimum400 PSI
Jumlah Palabuhan2
Rentang Suhu33 - 180 degrees F
Kisaran tekanan anu tiasa diatur25 - 75 PSI (Standard 50 PSI)
Tipe klepKlep Globe
SertifikasiASSE 1003, ANSI a112.26.2, IAPMO, NSF 61, CSA B356

Émbaran jaminan

The Watts LFN45B Pressure Reducing Valve comes with a Kawates Jaminan Hirupna. For specific terms, conditions, and claim procedures, please refer to the official Watts warranty documentation or visit their official websitus. Simpen bukti pameseran anjeun pikeun klaim garansi.

Rojongan jeung Kontak

For further assistance, technical support, or to inquire about replacement parts, please contact Watts customer service or visit their official websitus:

When contacting support, please have your product model number (LFN45B) and purchase details readily available.

Dokumén Patali - LFN45B

Praview Katup Pangurangan Tekanan Cai WATTS LFN45B - Manual Pamasangan sareng Pangropéa
Pituduh lengkep pikeun masang, ngoperasikeun, sareng ngungkulan masalah Katup Pangurangan Tekanan Cai WATTS LFN45B. Ngawengku peringatan kaamanan, pitunjuk pamasangan, prosedur pangaturan, sareng tip ngarengsekeun masalah pikeun sistem pipa ledeng.
Praview Watts LFN45B Series Water Pressure Reducing Valve Installation and Maintenance Guide
Comprehensive guide for installing, maintaining, and troubleshooting the Watts LFN45B Series water pressure reducing valve. Includes safety warnings, adjustment procedures, and warranty information.
Praview Pamasangan sareng Pangropéa Katup Pangurang Tekanan Cai Watts N55B-M1 sareng LFN55B-M1
Pituduh pamasangan, pangropéa, sareng ngungkulan masalah anu lengkep pikeun Katup Pangurang Tekanan Cai Watts N55B-M1 sareng LFN55B-M1, kalebet diagram sareng inpormasi garansi.
Praview Katup Pangurang Tekanan Watts kalayan Fitur Pamariksaan Hidrolik - Séri Stainless
Téknis leuwihview tina Katup Pangurangan Tekanan sareng Pariksa Kombinasi Watts ACV, anu ngajelaskeun operasina, pedoman pamasangan, sareng daptar modél klep kontrol anu aya hubunganana.
Praview Watts W-M115 ACV Pressure Reducing Valve: Specification & Installation Guide
Comprehensive guide detailing the specifications, dimensions, flow rates, operating principles, installation, and start-up procedures for the Watts W-M115 ACV Pressure Reducing Valve. Essential information for industrial and commercial applications.
Praview Pitunjuk Pamasangan Katup Pangurang Tekanan Cai Watts LF25AUB-Z3 Series
Pituduh pamasangan lengkep pikeun Katup Pangurang Tekanan Cai Watts LF25AUB-Z3 Series, anu ngajelaskeun sacara rinci tindakan pencegahan kaamanan, metode pamasangan (khas, séri, paralel), prosedur pangaturan, kit perbaikan, sareng tip ngungkulan masalah. Ngawengku pedaran tékstual ngeunaan diagram sareng bagian-bagianna.