1. Bubuka
This manual provides essential information for the safe and efficient installation, operation, and maintenance of your AERMEC OMNIA UL16P Fan Coil Unit. Please read this manual thoroughly before attempting to install or operate the unit. Keep this manual for future reference.
2. Produk Langkungview
The AERMEC OMNIA UL16P fan coil unit is designed for versatile installation, suitable for both horizontal and vertical wall mounting without a decorative cover. It incorporates a robust 3-speed centrifugal fan, ensuring efficient air circulation. This unit is capable of providing both heating and cooling, making it a comprehensive climate control solution. It can heat effectively at lower temperatures (50 °C) compared to traditional systems (70 °C), contributing to energy efficiency. The design prioritizes quiet operation.
fitur konci ngawengku:
- Version: UL-P
- Equipped with a 3-speed centrifugal fan
- Capable of heating at low temperatures (50 °C)
- Functions for both heating and cooling
- Designed for silent operation
- Features an easy-to-extract and clean air filter
- Facilitates condensate tray cleaning
- Allows for fan cleaning

Gambar 2.1: Hareupeun view of the AERMEC OMNIA UL16P Fan Coil Unit, showing its compact design for concealed installation.
3. Émbaran Kasalametan
Always observe the following safety precautions to reduce the risk of injury, electric shock, fire, or damage to the unit:
- Pamasangan sareng pangropéa ngan kedah dilakukeun ku tanaga anu mumpuni.
- Pastikeun catu daya dipegatkeun samemeh ngalakukeun pamasangan, pangropéa, atanapi perbaikan.
- Pariksa yén catu daya voltage cocog sareng spésifikasi unit.
- Do not block the air intake or outlet grilles.
- Jauhkeun bahan anu gampang kaduruk tina unit.
- Pastikeun grounding anu leres tina unit.
4. Setup jeung Instalasi
The OMNIA UL16P unit is designed for flexible installation. It can be mounted horizontally or vertically on a wall. Mounting hardware is included in the packaging to assist with installation.
4.1 Panyambungan Plumbing
The plumbing valves for water connections can be installed on either the right or left side of the unit, offering adaptability to various installation layouts. Ensure all connections are secure and leak-free.

Figure 4.1: Technical diagram illustrating various features and potential installation configurations of the AERMEC OMNIA UL-P series.

Figure 4.2: Dimensional drawing of the AERMEC OMNIA UL-P series, showing horizontal and vertical installation options and overall dimensions.
5. Operasi
The AERMEC OMNIA UL16P operates with a 3-speed centrifugal fan, allowing you to adjust the airflow and comfort level. The unit is designed for both heating and cooling functions.
5.1 Modeu pemanasan
In heating mode, the unit can effectively warm your space using water at a lower temperature of 50 °C, which is more energy-efficient than systems requiring 70 °C.
5.2 Modeu cooling
The unit also functions as an air conditioner, providing effective cooling to maintain a comfortable indoor environment.
5.3 Fan Speed Control
Utilize the 3-speed fan control to select the desired airflow and noise level. The unit is engineered for silent operation across all speeds.
6. Pangropéa
Regular maintenance ensures the longevity and optimal performance of your fan coil unit. Always disconnect power before performing any maintenance.
6.1 Filter hawa beberesih
The air filter is designed for easy extraction and cleaning. Periodically remove the filter and clean it with water or a vacuum cleaner to maintain air quality and unit efficiency. Ensure the filter is completely dry before reinstallation.
6.2 Condensate Tray Cleaning
Regularly inspect and clean the condensate tray to prevent blockages and the growth of mold or bacteria. Ensure the drain line is clear.
6.3 Pembersihan Kipas
Periodically clean the fan blades to remove dust and debris that can accumulate and reduce efficiency. Use a soft brush or cloth. Exercise caution to avoid damaging the fan components.
7. Cara ngungkulan
This section provides solutions to common issues you might encounter. For problems not listed here or if issues persist, contact qualified service personnel.
- Unit teu hurung: Check power supply, circuit breaker, and ensure the unit is properly connected.
- Insufficient heating/cooling: Verify fan speed settings, check air filter for blockages, ensure no obstructions to airflow, and confirm water supply to the coil.
- Sora anu teu biasa: Inspect fan for debris, check for loose components, or contact service if noise persists.
- bocor cai: Check condensate tray for blockages, ensure drain line is clear and properly sloped.
8. Spésifikasi
| Fitur | Spésifikasi |
|---|---|
| merek | AERMEC |
| Nomer modél | UL16P |
| Ukuran produk (L x W x H) | 54 x 47 x 18 cm |
| Beurat | 4 kg |
| Bahan | Lambaran logam |
| Métode Cooling | Hawa |
| Tipe Panyambung Daya | 3-pin |
| Alat nu cocog | Computer (Note: This specification may refer to control system compatibility.) |
| No Longer Manufactured | No |
| Kasadiaan suku cadang | Inpormasi teu sayogi |
| Tanggal Kahiji Sadia | 29 April 2022 |
9. Garansi jeung Rojongan
Specific warranty information for the AERMEC OMNIA UL16P is not provided in the available product details. Please refer to your purchase documentation or contact your retailer or AERMEC customer service for detailed warranty terms and conditions.
For technical support, service, or spare parts inquiries, please contact your local AERMEC distributor or authorized service center. Information regarding spare parts availability is currently unavailable through the provided product details.
Manufacturer: AERMEC





