This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of the Carlin 50824 24 Volt Gas Valve. Please read this manual thoroughly before attempting any procedures to ensure proper function and to prevent potential hazards.
Émbaran Kasalametan penting
PERHATOSAN: Pamasangan, panyesuaian, parobahan, palayanan, atanapi pangropéa anu teu leres tiasa nyababkeun karusakan harta, tatu, atanapi maot. Baca paréntah pamasangan, operasi, sareng pangropéa sacara saksama sateuacan masang atanapi ngalayanan alat ieu.
- Pamasangan sareng palayanan kedah dilakukeun ku pamasang, agénsi jasa, atanapi supplier gas anu mumpuni.
- Always turn off the gas supply and electrical power before servicing the valve.
- Check for gas leaks after any service or installation.
- Entong nyimpen atanapi nganggo béngsin atanapi uap sareng cairan anu gampang kaduruk di sakuriling ieu atanapi alat anu sanés.
Produk Leuwihview
The Carlin 50824 is a 24 Volt gas valve designed for controlling gas flow in compatible heating systems. It features a robust construction and is engineered for reliable performance. This valve is specifically designed for EZ Gas applications.

Figure 1: Carlin 50824 24 Volt Gas Valve. This image displays the gas valve unit, highlighting its main body, control knob, and electrical connection points.
Setup sareng Instalasi
Installation of the Carlin 50824 gas valve should only be performed by a qualified technician in accordance with all local codes and regulations.
Cék Pra-Pasang:
- Verify that the gas type and pressure match the valve's specifications.
- Ensure the electrical supply is 24 Volts AC.
- Inspect the valve for any signs of damage from shipping.
- Confirm all necessary tools and fittings (e.g., Barb connection type) are available.
Léngkah-léngkah pamasangan:
- Turn off Power and Gas: Disconnect all electrical power and shut off the main gas supply to the appliance.
- Cabut Old Valve (upami aya): Carefully disconnect and remove the existing gas valve, if replacing.
- Pasang Katup Anyar: Securely mount the Carlin 50824 valve in the correct orientation, ensuring it is level.
- Connect Gas Lines: Connect the gas inlet and outlet lines to the valve using appropriate fittings. The valve uses Barb type connections. Ensure all connections are tight and leak-free.
- Wire Electrical Connections: Connect the 24 Volt AC wiring to the designated terminals on the valve. Refer to the appliance's wiring diagram for correct connections.
- Pariksa bocor: After installation, slowly turn on the gas supply and check all gas connections for leaks using a suitable leak detection solution.
- Mulangkeun Daya: Sakali sadaya sambungan parantos aman sareng henteu bocor, hurungkeun deui daya listrik ka alat.
Parentah Operasi
The Carlin 50824 gas valve operates in conjunction with your heating system's control board to regulate gas flow. Its primary function is to open and close to allow or restrict gas to the burner.
Operasi dasar:
- When the thermostat calls for heat, the control board sends a 24 Volt signal to the gas valve.
- The valve opens, allowing gas to flow to the burner.
- Once the desired temperature is reached, the signal is removed, and the valve closes, shutting off the gas supply.
- Some models may feature a manual ON/OFF knob (as seen in Figure 1). Ensure this knob is in the "ON" position for automatic operation. For service or extended shutdown, turn it to "OFF".
Pangropéa
Regular maintenance ensures the longevity and safe operation of your gas valve. All maintenance should be performed by a qualified service technician.
Pangropéa anu disarankeun:
- Inspeksi taunan: Have a qualified technician inspect the gas valve annually for signs of wear, corrosion, or leaks.
- beberesih: Keep the area around the valve clean and free from dust and debris. Do not use harsh chemicals for cleaning.
- Cék operasional: During annual service, ensure the valve opens and closes smoothly and reliably.
Do not attempt to disassemble or repair the gas valve yourself. Internal components are not user-serviceable.
Pamérésan masalah
If you experience issues with your Carlin 50824 gas valve, consult the table below for common problems and potential solutions. For complex issues, always contact a qualified service technician.
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| No gas flow to burner |
|
|
| Irregular gas flow or burner ignition issues |
|
|
Always ensure gas and electrical power are off before inspecting connections. If you suspect a gas leak, immediately shut off the main gas supply and ventilate the area. Do not operate any electrical switches or phones. Contact your gas supplier and a qualified technician.
spésifikasi
| Fitur | Rincian |
|---|---|
| merek | Carlin |
| Nomer modél | 50824 |
| Voltage | 24 volt |
| Aplikasi | EZ Gas |
| Tipe Sambungan Inlet | Barb |
| Tipe Sambungan Outlet | Barb |
| Jumlah Palabuhan | 2 |
| Ukuran barang (L x W x H) | 3 x 2 x 2 inci |
| Item Beurat | 2.37 pon |
Garansi sareng Rojongan
For specific warranty information regarding the Carlin 50824 24 Volt Gas Valve, please refer to the documentation provided with your purchase or contact Carlin directly. Warranty terms typically cover manufacturing defects for a specified period from the date of purchase.