Apogee MQ-210

Apogee MQ-210 Underwater Quantum Light PAR Meter User Manual

Model: MQ-210

1. Bubuka

The Apogee MQ-210 Quantum Light PAR Meter is designed for precise measurement of Photosynthetic Active Radiation (PAR) in underwater environments. This device features a waterproof quantum sensor connected to a handheld meter. The MQ-210 is specifically engineered to apply an immersion effect correction factor directly through its firmware, ensuring accurate readings in aquatic settings. It is suitable for various light sources, though specific post-measurement correction factors may be required for LED light sources to achieve optimal accuracy.

Important Note: While the sensor and its cable are fully waterproof, the handheld meter unit is NOT waterproof and must be kept dry.

2. Émbaran Kasalametan

  • Always ensure the handheld meter remains dry. Exposure to water will damage the unit and void the warranty.
  • Do not attempt to open or modify the handheld meter or the sensor. This can lead to damage and inaccurate readings.
  • Handle the sensor cable with care to prevent kinks or damage, which could compromise its waterproof integrity.
  • Keep the device away from extreme temperatures and direct sunlight when not in use.
  • Use only specified batteries (if applicable, refer to product packaging or Apogee documentation).

3. Eusi Paket

Saatos ngabongkar bungkusan, mangga pariksa yén sadaya komponén ieu aya:

  • Apogee MQ-210 Handheld Meter
  • Waterproof Quantum Sensor (attached via cable)
  • Manual pangguna (dokumén ieu)

4. Produk Langkungview

The MQ-210 system comprises two main parts: the handheld display unit and the waterproof quantum sensor.

Apogee MQ-210 Underwater Quantum Light PAR Meter with handheld unit and sensor

Gambar 1: Apogee MQ-210 Underwater Quantum Light PAR Meter. This image displays the complete MQ-210 unit, featuring the handheld meter with its digital display and control buttons, connected by a cable to the compact, black waterproof quantum sensor. The sensor is designed for submersion, while the handheld unit is for dry use.

4.1 Handheld Meter

The handheld meter features a digital display for showing PAR readings in µmol m⁻² s⁻¹. It includes control buttons for power, sampling, and mode selection. The meter processes the raw sensor data and applies the immersion effect correction factor.

4.2 Waterproof Quantum Sensor

Close-up of Apogee waterproof quantum sensor

Gambar 2: Pahareup-hareup view of the Apogee waterproof quantum sensor. This image highlights the robust, anodized aluminum body and the acrylic diffuser of the sensor head. The sensor contains a blue-enhanced silicon photodiode and custom optical filters, designed for accurate underwater PAR measurements.

The sensor incorporates a blue-enhanced silicon photodiode and custom optical filters housed within a rugged, anodized aluminum body with an acrylic diffuser. It is designed for full submersion in water, making it ideal for applications such as saltwater aquariums.

5. Setélan

  1. Buka bungkus Alat: Carefully remove the handheld meter and sensor from its packaging.
  2. Pariksa Karusakan: Check the handheld meter, sensor, and cable for any visible signs of damage. If damage is found, do not proceed with setup and contact support.
  3. Pamasangan batré (upami tiasa dianggo): If the meter requires user-installed batteries (not specified, but common for handheld devices), open the battery compartment (usually on the back) and insert the correct type and number of batteries, observing polarity.
  4. Sambungan sénsor: The quantum sensor is permanently attached to the handheld meter via a waterproof cable. Ensure the cable connection point to the sensor is secure and undamaged.
  5. Daya mimiti Hurung: Press the power button on the handheld meter to turn it on. The display should illuminate and show a reading.

6. Parentah Operasi

6.1 Powering on / Pareum

  • To power on the meter, press the Kakuatan button (usually marked with a circle and vertical line symbol).
  • Pikeun pareum, pencét jeung tahan Kakuatan tombol nepi ka tampilan pareum.

6.2 Nyokot Pangukuran

  1. Posisi sénsor: Carefully submerge the waterproof quantum sensor into the water at the desired depth and location for measurement. Ensure the sensor's acrylic diffuser is clean and unobstructed.
  2. Observe Readings: The handheld meter's display will show the real-time PAR reading in µmol m⁻² s⁻¹. The MQ-210 automatically applies the immersion effect correction factor in its firmware for underwater measurements.
  3. Sampling (if applicable): If the meter has a "sample" button, pressing it may log the current reading or provide a stable reading. Refer to the on-screen indicators for specific sampfungsi ling.
  4. Pilihan Modeu (upami aya): Use the "mode" button to cycle through different display modes or settings if available.

6.3 LED Light Source Considerations

While the MQ-210 is excellent for most light sources, when measuring PAR from LED light sources, post-measurement correction factors may need to be applied for the most accurate results. Consult Apogee Instruments' official documentation or website for specific correction factors pertaining to various LED types.

7. Pangropéa

7.1 beberesih

  • Sénsor: After each use in water, rinse the sensor with fresh water to remove any salt, debris, or biological film. Gently wipe the acrylic diffuser with a soft, non-abrasive cloth. Avoid using harsh chemicals or abrasive materials that could scratch the diffuser.
  • Handheld Meter: Clean the handheld meter with a dry, soft cloth. Do not use liquid cleaners or immerse the meter in water.

7.2 Panyimpenan

  • Store the MQ-210 in a cool, dry place away from direct sunlight and extreme temperatures.
  • If storing for extended periods, remove batteries from the handheld meter to prevent leakage (if applicable).
  • Keep the sensor and cable free from kinks or sharp bends during storage.

8. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Méter teu hurung.Batré paéh atawa salah dipasang.Ganti batré ku nu anyar, mastikeun polaritasna bener.
Bacaan anu teu akurat atanapi teu teratur.
  • Dirty sensor diffuser.
  • Damaged sensor or cable.
  • Incorrect application of LED correction factor (for LED sources).
  • Clean the sensor diffuser gently.
  • Inspect sensor and cable for damage. If damaged, contact support.
  • Refer to Apogee documentation for LED correction factors.
Display shows "Error" or unusual characters.Masalah internal atanapi sensor masalah.Try powering off and on again. If the error persists, contact Apogee Instruments support.
Tombol-tombol henteu ngaréspon.Internal button malfunction or software issue.Power cycle the device. If buttons remain unresponsive, contact Apogee Instruments support.

9. Spésifikasi

FiturRincian
ModélMQ-210
Tipe PangukuranUnderwater Photosynthetic Active Radiation (PAR)
Tipe sénsorBlue-enhanced silicon photodiode with custom optical filters
Bahan Awak sénsorRugged, anodized aluminum with acrylic diffuser
Immersion Effect CorrectionAutomatically applied via firmware
Handheld Meter Water ResistanceTeu waterproof
Sensor Water ResistanceLengkep waterproof
ProdusénInstrumen Apogee

10. Garansi jeung Rojongan

For detailed warranty information, technical support, or service inquiries, please contact Apogee Instruments directly. Refer to their official websitus kanggo inpormasi kontak sareng kawijakan garansi pangénggalna.

It is recommended to register your product with Apogee Instruments to ensure you receive updates and support.

Dokumén Patali - MQ-210

Praview Apogee Duet 2 User Guide: Setup, Operation, and Applications
This user guide provides comprehensive instructions for the Apogee Duet 2 audio interface, covering setup, connection, operation, integration with DAWs like Logic Pro and GarageBand, and troubleshooting for Mac users.
Praview Apogee Symphony I / O ngungkulan: Taya Power Dina Isu
Buletin téknis ti Apogee Electronics nyayogikeun léngkah-léngkah pikeun ngarengsekeun masalah 'teu aya daya on' sareng antarmuka audio Symphony I/O. Nyertakeun gejala umum sareng nungtun pangguna pikeun mariksa firmware, kabel, catu daya, sareng papan sirkuit.
Praview Apogee Duet 3 User's Guide
Comprehensive user guide for the Apogee Duet 3 audio interface, covering setup, software installation, connectivity, configuration with DAWs, advanced features, and troubleshooting.
Praview Apogee Clearmountain's Dance User's Guide: Delay Plugin Features and Setup
Comprehensive user guide for Apogee's Clearmountain's Dance delay plugin. Learn about its analog tape emulation, ping pong delay, installation, signal routing, and troubleshooting.
Praview Pituduh Pamaké Apogee Symphony Studio: Interface Audio Resolusi Tinggi
Buku pituduh komprehensif pikeun panganteur audio Apogee Symphony Studio Series, ngawengku setelan, operasi, kontrol software, workflows monitor, sarta spésifikasi teknis pikeun produksi audio profésional.
Praview Sistem Subwoofer Apogee AFI-118: Subwoofer Audio Profesional 18 inci Kinerja Tinggi
Spésifikasi lengkep sareng fitur tina Sistem Subwoofer Apogee AFI-118, subwoofer kakuatan tinggi 18 inci (460mm) dirancang pikeun aplikasi audio profésional, kalebet sora langsung, klub, sareng bioskop. Diajar ngeunaan supirna, data rékayasa, sareng kasaluyuan.