Commax TP-12RM

Commax TP-12RM Master Interphone System User Manual

Models: TP-12RM (Master Unit), TP-S (Remote Unit), RF-24015S (Power Supply)

1. Bubuka

This manual provides comprehensive instructions for the installation, operation, and maintenance of your Commax TP-12RM Master Interphone System. This system facilitates communication between a central master unit and up to twelve remote units. Please read this manual thoroughly before operating the system to ensure proper function and safety.

2. Émbaran Kasalametan

  • Ensure all wiring is performed by a qualified professional to prevent electrical hazards.
  • Use only the provided RF-24015S DC24V power supply. Using an incorrect power supply may damage the units and void the warranty.
  • Do not expose the units to water, excessive moisture, or extreme temperatures.
  • Do not attempt to open or repair the units yourself. Refer all servicing to authorized personnel.
  • Keep the units away from strong electromagnetic fields.

3. Eusi Paket

Pastikeun yén sadaya komponén aya dina bungkusan:

  • 1 x Commax TP-12RM Master Unit
  • 12 x Commax TP-S Remote Units
  • 1 x Commax RF-24015S DC24V Power Supply
Commax TP-12RM Master Interphone System with 12 TP-S Remote Units and RF-24015S Power Supply

Gambar 1: Leuwihview of the Commax TP-12RM Master Interphone System components. This image displays the TP-12RM master unit on the left, twelve TP-S remote units arranged in two rows on the right, and the RF-24015S power supply at the bottom left. All units are white and feature a classic interphone design with coiled handsets.

4. Setup jeung Instalasi

4.1 Diagram Wiring

The Commax TP-12RM system requires a 2-wire connection for each remote unit to the master unit. The power supply connects directly to the master unit. Ensure proper polarity during wiring.

Commax TP-12RM System Wiring Diagram

Gambar 2: System Wiring Diagram for the Commax TP-12RM. This diagram illustrates the connection of the TP-12RM master unit (represented by a central circuit board with terminals) to multiple TP-S remote units (shown as handsets). Each TP-S unit connects to the master unit via two wires. The DC24V power supply is shown connected to the master unit, providing power to the entire system.

4.2 Léngkah-léngkah Instalasi

  1. Pamasangan: The master unit (TP-12RM) can be wall or desktop surface mounted. The remote units (TP-S) are surface mounted. Choose appropriate locations for optimal communication and accessibility.
  2. Wiring: Connect each TP-S remote unit to the TP-12RM master unit using a 2-wire cable. Ensure secure connections at all terminals. The maximum transmission distance is up to 1000 meters (3000 feet) with Ø0.65mm wire.
  3. Sambungan catu daya: Connect the RF-24015S DC24V power supply to the designated power input terminals on the TP-12RM master unit.
  4. Daya Hurung: Plug the power supply into a standard AC outlet (AC100V-240V, 50/60Hz). The system will power on.

5. Parentah Operasi

5.1 Making a Call (Master to Remote)

  1. Lift the handset on the TP-12RM master unit.
  2. Press the button corresponding to the desired remote unit (1-12).
  3. An electric call tone will sound at the remote unit.
  4. When the remote unit lifts its handset, communication can begin.

5.2 Making a Call (Remote to Master)

  1. Lift the handset on the TP-S remote unit.
  2. A melody sound will be heard at the TP-12RM master unit.
  3. The LED indicator on the master unit corresponding to the calling remote unit will illuminate.
  4. The master unit operator lifts the handset to establish communication.

5.3 Komunikasi

Once a call is established, speak clearly into the handset. The system supports two-way communication between the master unit and one remote unit at a time. Remote units cannot communicate directly with each other.

6. Pangropéa

  • beberesih: Ngusap unit ku kaén anu lembut sareng garing. Ulah make cleaners abrasive atawa pangleyur.
  • Pamariksaan: Periodically check all wiring connections for security and signs of wear.
  • Lingkungan: Ensure the units are kept in a clean, dry environment within the specified operating temperature range (0°C ~ 40°C / 32°F ~ 104°F).

7. Cara ngungkulan

If you encounter issues with your Commax interphone system, refer to the following common problems and solutions:

  • Henteu aya kakuatan:
    • Check if the power supply is securely plugged into a working outlet.
    • Verify the power supply connection to the master unit.
  • Henteu aya komunikasi:
    • Ensure all wiring connections between the master and remote units are secure and correctly polarized.
    • Check if the correct remote unit button is pressed on the master unit.
    • Confirm both handsets are lifted during a call.
  • Kualitas Audio goréng:
    • Inspect wiring for damage or loose connections.
    • Ensure the transmission distance does not exceed 1000 meters with the recommended wire gauge.
  • Remote Unit Not Ringing:
    • Verify the wiring to that specific remote unit.
    • Ensure the master unit is powered on and functioning.

Lamun masalah persist, kontak rojongan customer pikeun pitulung.

8. Spésifikasi

Detailed specifications for the Commax TP-12RM Master Unit, TP-S Remote Unit, and RF-24015S Power Supply are provided below:

Commax Interphone System Specifications Table

Gambar 3: Detailed specifications for the Commax TP-12RM Master Unit, TP-S Remote Unit, and RF-24015S Power Supply. This image presents a table format outlining key technical details such as model numbers, power sources, mounting types, wiring requirements, operating temperatures, dimensions, transmission distances, and call tone types for each component of the interphone system.

Commax Interphone System Specifications
FiturTP-12RM (Master Unit)TP-S (Remote Unit)RF-24015S (Power Supply)
Nomer modélTP-12RMTP-SRF-24015S
Sumber DayaDC24V, 1.5A (from RF-24015S)DC24V (from TP-12RM)AC100V-240V 50/60Hz Input, DC24V 1.5Amp Kaluaran
Tipe PamasanganWall or Desktop Surface MountedSurface dipasangPermukaan Gunung
Suhu Operasi0°C ~ 40°C (32°F ~ 104°F)
Wiring2 wires per substationN/A
Jarak PangirimanUp to 1000 meters / 3000 feet (Ø0.65mm wire)N/A
Diménsi (mm)116 x 208 x 6772 x 215 x 38N/A
Nelepon NadaElectric call tone (to sub-unit), Melody sound (from sub-unit)Electric call tone (from master), Melody sound (to master)N/A
KonektipitasSupports up to 12 units of TP-S (Sub-unit)Connects to TP-12RM Master UnitN/A
Tipe ColokkeunN/AN/AUS Type A, 2-blades prong

9. Garansi jeung Rojongan

Commax products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your purchase or contact your authorized Commax dealer. For technical support or service inquiries, please contact Commax customer service through their official websitus atanapi inpormasi kontak anu disayogikeun nalika mésér.

Dokumén Patali - TP-12RM

Praview COMMAX CCU-204AGF Parabot Parobah Unit Manual
Buku pituduh pikeun unit konvérsi COMMAX CCU-204AGF, ngajéntrékeun fitur, pungsi, pamasangan, sareng spésifikasina. Ngawengku warnings kaamanan sarta hidayah operasional.
Praview COMMAX CCU-208AGF Parabot Parobah Unit Manual
Manual pamaké pikeun Unit Konverter COMMAX CCU-208AGF, detailing fitur, warnings, fungsi, parentah pamakéan, diagram sistem, wiring, precautions, sarta spésifikasi.
Praview COMMAX Door Phone DP-4VHP Manual Pamaké jeung Guide Kasalametan
Manual pamaké komprehensif pikeun COMMAX DP-4VHP Door Phone, ngawengku instalasi, operasi, precautions kaamanan, spésifikasi, sarta informasi kontak. Fitur parentah jelas tur warnings.
Praview Katalog Wideodomofonów sareng Systemów Bezpieczeństwa COMMAX
Poznaj pełną ofertę wideodomofonów, domofonów jeung systemów bezpieczeństwa Smart Home marks COMMAX. Katalog szczegółowe opisy produktów, specyfikacje techniczne i rozwiązania dla domu i firmy.
Praview Kumaha Paké Commax CDV-70QT Video Door Phone: Manual basajan
Pitunjuk singket dina nyambungkeun sareng nganggo telepon panto vidéo Commax CDV-70QT sareng smartphone anjeun, kalebet fitur sapertos telepon sémah, deteksi gerak, sareng setélan kaamanan.
Praview COMMAX DP-ML Apartment House Intercom User Manual
User manual for the COMMAX DP-ML Apartment House Intercom system, detailing its controls, operation, installation, wiring, and specifications. Includes information for roomstation and guardhouse communication.