1. Setup jeung Instalasi
The AC Infinity CLOUDPLATE T9 is designed for installation in standard 19-inch equipment racks, occupying three rack units (3U) of space. Ensure adequate space and ventilation around the unit for optimal performance.
1.1 Eusi pakét
Sateuacan masang, pariksa yén sadaya komponén aya:
- CLOUDPLATE T9 Fan Unit
- Corded 6-ft Thermal Probe
- Rack Mount Screws
- Kandang Kacangan
- Corded 6-ft Power Supply

Gambar 1.1: Included accessories for the CLOUDPLATE T9, featuring the thermal probe, power supply, and mounting hardware.
1.2 Pasang Unit
- Identify the desired 3U rack space for installation. The unit is designed for exhaust airflow and should ideally be positioned near the top of the rack to effectively remove heated air.
- Align the mounting holes on the CLOUDPLATE T9 with the corresponding holes on your equipment rack.
- Secure the unit using the provided rack mount screws and cage nuts. Ensure the unit is firmly attached to prevent vibration.

Gambar 1.2: The CLOUDPLATE T9 unit securely mounted within an equipment rack.
1.3 Connecting the Thermal Probe and Power
- Connect the thermal probe to the designated port on the CLOUDPLATE T9 unit.
- Position the thermal probe within the rack where temperature monitoring is most critical, typically near heat-generating equipment. The probe cable is 6 feet long, allowing flexible placement.
- Connect the power supply to the unit and then plug it into a standard 100-240V AC outlet.

Gambar 1.3: Hareupeun view of the CLOUDPLATE T9, showcasing its digital display and fan grilles.
2. Parentah Operasi
The CLOUDPLATE T9 features an intelligent LCD digital controller for precise temperature management and fan speed control.
2.1 Controller Leuwihview
The front panel LCD displays current temperature, set temperature, fan speed, and various status indicators. Buttons allow for easy navigation and setting adjustments.

Gambar 2.1: Diwincik view of the intelligent programming features on the CLOUDPLATE T9 controller.
2.2 Modeu Operasi sareng Setélan
The controller offers automated speed control and various programmable features:
- Mode pinter: Automatically adjusts fan speed in response to varying temperatures, optimizing cooling efficiency and noise levels.
- Modeu Manual: Allows users to set a fixed fan speed from 1 to 6.
- Alarm Suhu: Bewara anu tiasa dikonfigurasi pikeun suhu anu luhur.
- Fan Failure Triggers: Notifies users if a fan is not operating correctly.
- Power Savings Setting: Optimalkeun konsumsi énergi.
- Konci tampilan: Nyegah parobahan teu kahaja kana setélan.
- Mémori Cadangan: Nahan setélan salila kakuatan outages.
Refer to the on-screen menu for detailed instructions on adjusting specific settings.
2.3 Airflow and Cooling Principles
The CLOUDPLATE T9 is an exhaust fan system, designed to pull hot air out of the rack. For optimal cooling, it is recommended to have an intake fan system at the bottom of the rack to draw in cooler air, creating a consistent airflow path.

Gambar 2.2: Illustration of effective airflow management within an equipment rack using rack fans.
2.4 Daisy-Chaining Multiple Units
For enhanced cooling in larger setups, additional CLOUDPLATE units can be daisy-chained to share the same controller programming. This allows for synchronized operation and centralized control of multiple fan panels.
Klip 2.1: An official product video from AC Infinity demonstrating the features and benefits of the CLOUDPLATE Series rack mount cooling fan systems, including intelligent programming and daisy-chaining capabilities.
3. Pangropéa
Regular maintenance ensures the longevity and optimal performance of your CLOUDPLATE T9 unit.
3.1 beberesih
Periodically inspect the fan grilles and blades for dust accumulation. Use a soft brush or compressed air to gently clean the surfaces. Ensure the unit is powered off before cleaning.
3.2 Fan Longevity
The CLOUDPLATE T9 features custom-engineered dual-ball bearing fans, rated for an L10 life expectancy of 67,000 hours. These bearings allow for reliable operation in both horizontal and vertical mounting positions.

Gambar 3.1: Illustration of the dual-ball bearing fan design, engineered for durability and quiet operation.
4. Cara ngungkulan
This section addresses common issues you might encounter with your CLOUDPLATE T9.
4.1 Fan Not Operating
- Pariksa kakuatan: Ensure the power supply is securely connected to both the unit and a working electrical outlet.
- Setélan Controller: Verify that the fan speed is not set to zero or that the unit is not in a mode that keeps fans off (e.g., if the temperature is below the set threshold in SMART mode).
- Fan Failure Warning: If a fan failure warning is displayed, inspect the individual fans for obstructions or damage.
4.2 Noise kaleuleuwihan
- Laju kipas: Higher fan speeds (levels 4-6) will naturally produce more noise. Consider using SMART mode to allow the unit to adjust speed based on temperature, often resulting in quieter operation.
- Halangan: Ensure no cables or other objects are interfering with the fan blades.
- Pamasangan: Verify the unit is securely mounted and not vibrating against the rack frame.
4.3 Cooling teu epektip
- Airflow Path: Confirm that there is a clear path for cool air intake (typically at the bottom of the rack) and hot air exhaust (at the CLOUDPLATE T9). Blocked vents or equipment can hinder airflow.
- Thermal Probe Placement: Ensure the thermal probe is positioned accurately to measure the hottest area within the rack.
- Laju kipas: Increase the fan speed or adjust SMART mode settings to a lower target temperature if equipment is still overheating.
5. Spésifikasi
5.1 Idéntifikasi produk
| Produsén | AC Infinity Nyarita. |
| Ngaran produk | CLOUDPLATE T9 |
| Modél produk | AI-CPT9 |
| Kodeu UPC | 819137020023 |
5.2 Product and Mounting Dimensions
| Total Diménsi | 19.0 x 5.25 x 2.0 inci (48.3 x 13.3 x 5.2 cm) |
| Rack Mount Size | Three Rack Units (3U) |
| Screw Hole Size | Ø .24 x 0.35 in. (Ø 6.1 x 9.0 mm) |
| Obround Hole to Hole Distance | 18.2 x 2.25 inci. (46.4 x 5.7 cm) |
| Ukuran tampilan | 2.25 x 1.25 inci. (4.7 x 3.2 cm) |
| Panjang Probe | 72 in. (6 feet) |
| Panjang Tali | 72 in. (6 feet) |

Gambar 5.1: Dimensional specifications of the CLOUDPLATE T9 unit.
5.3 Product Performance and Technical Specs
| Desain | knalpot |
| Total Aliran Udara | 60 nepi ka 300 CFM |
| Total Noise | 12 nepi ka 38 dBA |
| Tekanan statik | 2.56 mm-H2O |
| Operasi Voltage | 12V DC |
| Kakuatan | 12 W |
| ayeuna | 1 A |
| Input adaptor témbok | 100 nepi ka 240V AC |
| Kalembaban Operasi | 35 nepi ka 85% RH |
| Suhu Operasi | 0 nepi ka 158 ° F |
| Bantalan kipas | Bola Ganda |
| Posisi Pasang | Horisontal atanapi tangtung |
| L10 Harapan Hirup | 67,000 Jam |
| Bahan | alumunium |
6. Garansi jeung Rojongan
The AC Infinity CLOUDPLATE T9 is manufactured with high-quality components, including dual-ball bearing fans designed for a long operational life of 67,000 hours.
For specific warranty information, technical support, or service inquiries, please refer to the official AC Infinity websitus atanapi ngahubungan layanan palanggan maranéhanana langsung. Simpen resi pameseran anjeun pikeun klaim jaminan.