1. Bubuka
The Einhell GE-SP 3046 RB is a versatile multi-function pump designed for efficient rainwater collection and drainage. Its robust construction and intelligent features make it ideal for various applications around the home and garden, such as emptying rain barrels, tanks, or small ponds, and transferring water for irrigation. This manual will guide you through the proper use and care of your pump.

Figure 1.1: Einhell GE-SP 3046 RB Multi-function Pump with Accessories.
2. Parentah Kasalametan
Always read and follow all safety instructions before operating the pump.
- Pastikeun catu daya cocog sareng voltage anu ditangtukeun dina labél rating pompa.
- Never operate the pump with a damaged power cable or plug. Have any damage repaired by a qualified electrician.
- Do not lift or carry the pump by its power cable.
- Jauhkeun barudak sareng jalma anu henteu sah ti daérah operasi.
- Do not pump flammable, corrosive, or explosive liquids.
- Ensure the pump is fully submerged in water during operation to prevent dry running and overheating.
- Disconnect the pump from the power supply before performing any maintenance, cleaning, or when not in use.
- Ngajaga pompa tina ibun.
3. Komponén produk
The Einhell GE-SP 3046 RB pump comes with several key components for its multi-functional use:
- Unit Pompa: The main submersible pump with integrated motor and power cable.
- Saklar ngambang: Automatically activates/deactivates the pump based on water level.
- Fleksibel Gooseneck: Allows for precise water discharge direction.
- Adjustable Aluminum Tube: Provides variable height for water extraction, especially from deep containers.
- Rain Stand: A stable base for positioning the pump and extension tube in rain barrels.
- Integrated Cable Rewind: Convenient storage for the power cable on the pump housing.
- Extension Tube Storage: Dedicated compartment on the pump housing for storing extension tubes.

Figure 3.1: Close-up of the Pump Unit.

Figure 3.2: Flexible Gooseneck.

Figure 3.3: Extension Tube Storage.
4. Setélan
Follow these steps to set up your Einhell pump for operation:
- Assemble the Extension: If using the pump for rainwater collection from a barrel, attach the adjustable aluminum tube to the pump's outlet. Then, connect the flexible gooseneck to the top of the aluminum tube.
- Pasang Pompa: Place the pump unit into the water source (e.g., rain barrel, tank, or flooded area). Ensure the pump is stable and fully submerged. The minimum operating space required is approximately 40 x 40 cm, with a pump diameter of 24 cm.
- Adjust the Float Switch: The float switch controls the automatic on/off function of the pump. Adjust its position along the cable to set the desired minimum and maximum water levels for operation. A higher float position will require more water to activate the pump.
- Nyambung ka Daya: Plug the pump's power cable into a properly grounded electrical outlet. Ensure the outlet is protected by a residual current device (RCD) for safety.

Figure 4.1: Minimum Operating Space.

Figure 4.2: Adjusting the Float Switch.
5. Nyuping
Once set up, the Einhell GE-SP 3046 RB pump operates efficiently:
- Operasi otomatis: The pump will automatically start when the water level rises to the activation point set by the float switch and stop when the water level drops below the deactivation point.
- Operasi manual: For continuous operation regardless of water level (e.g., for complete drainage), the float switch can often be fixed in an 'on' position. Refer to the specific instructions for your float switch model.
- Water Transfer: Direct the flexible gooseneck or connected hose to where you want the water to be discharged. The pump can deliver up to 4,600 liters per hour with a maximum delivery height of 11 meters.

Figure 5.1: Pump in use for rainwater collection.
6. Pangropéa
Pangropéa rutin mastikeun umur panjang sareng kinerja pompa anjeun anu optimal:
- beberesih: After each use, especially when pumping dirty water, rinse the pump with clean water. Remove any debris or foreign objects from the intake area at the bottom of the pump.
- Pariksa keur blockages: Periodically inspect the pump's intake and outlet for any blockages that could impede water flow.
- Pamariksaan kabel: Regularly check the power cable for any signs of wear, cuts, or damage.
- Panyimpenan usum salju: Before the first frost, completely drain the pump of all water to prevent damage from freezing. Store the pump in a dry, frost-free location.
7. Cara ngungkulan
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Pompa teu ngamimitian | Taya catu daya Saklar ngambang teu diaktipkeun Motor overloaded / overheated | Pariksa sambungan kakuatan sarta sekering Adjust float switch position or manually activate Disconnect power, let cool down, check for blockages |
| Laju aliran low | Partial blockage in intake/outlet Selang bengkok atanapi panjang teuing/heureut Tingkat cai henteu cekap | Clean intake and outlet Check hose for kinks, use appropriate diameter Ensure pump is adequately submerged |
| Pompa ngalir terus | Float switch stuck in 'on' position Water level not dropping below deactivation point | Check float switch for free movement Ensure proper float switch adjustment for deactivation |
8. Spésifikasi
| Fitur | Spésifikasi |
|---|---|
| Modél | GE-SP 3046 RB |
| Nomer Artikel | 4170438 |
| Kakuatan | 350 W |
| Voltage | 230 V |
| Max. Laju Aliran | 4,600 L/h (4.6 Litres per second) |
| Max. Jangkungna pangiriman | 11 m |
| Max. Impurity Size | 2.5 mm |
| Panjang kabel | 10 m |
| Bahan | Impact-resistant PVC Plastic |
| Beurat | 3.8 kg |
| Ukuran (L x W x H) | 17 x 23 x 51 cm |
9. Garansi jeung Rojongan
Einhell products are manufactured with high-quality materials and undergo strict quality controls. For information regarding warranty terms and conditions, please refer to the warranty card included with your product or visit the official Einhell website. For technical support, spare parts, or service inquiries, please contact Einhell customer service directly. Keep your purchase receipt as proof of purchase.