This manual provides essential information for the proper installation, operation, and maintenance of the Red Lion PXU10020 PID Controller. The PXU10020 is a 1/16 DIN universal input controller with relay output, designed for precise temperature and process control applications. Please read this manual thoroughly before attempting to install or operate the device to ensure safe and efficient performance.

2. Émbaran Kasalametan

WARNING: Risk of electric shock. Disconnect power before installation or servicing.

3. Setélan

3.1. Pamasangan

The PXU10020 is a 1/16 DIN panel mount controller. Cut a panel opening of 45 mm x 45 mm (1.77 in x 1.77 in). Insert the controller into the opening and secure it using the provided mounting brackets. Ensure a snug fit to prevent dust and moisture ingress.

3.2. Kabel

Connect the power supply, universal input sensor, and relay output according to the wiring diagram provided with the product. The universal input supports various sensor types (thermocouple, RTD, voltage, current). The relay output provides switching capabilities for control elements. Ensure all connections are secure and correctly polarized.

Red Lion PXU10020 PID Controller front view

Gambar 1: Hareupeun view of the Red Lion PXU10020 PID Controller. This image displays the compact 1/16 DIN form factor, typical display, and control buttons for parameter adjustment and monitoring.

3.3. Mimiti Power-Up

After all wiring is complete and verified, apply power to the controller. The display will illuminate, and the controller will perform a self-test. Refer to the display for any initial error messages.

4. Nyuping

4.1. Basic Control Modes

The PXU10020 supports various control modes, including PID (Proportional-Integral-Derivative) and On/Off control. The appropriate mode should be selected based on the application requirements for stability and precision.

4.2. Parameter Setélan

Use the front panel buttons to navigate through the menu structure and set parameters such as the desired setpoint, alarm limits, and PID tuning constants (P, I, D values). Consult the detailed programming guide for specific menu navigation and parameter definitions.

4.3. Display Interpretation

The controller's display typically shows the current process value (PV) and the setpoint (SP). Status indicators may include output status, alarm status, and auto/manual mode. Refer to the controller's display legend for detailed icon meanings.

5. Pangropéa

5.1. beberesih

Bersihkeun panel hareup sacara berkala nganggo lap anu lemesamp cloth. Do not use abrasive cleaners or solvents, as these can damage the display and housing. Ensure no liquid enters the controller.

5.2. Kalibrasi

For critical applications, periodic calibration of the input sensor and controller may be required. Refer to the manufacturer's recommendations or consult a qualified service technician for calibration procedures.

6. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Kontroler teu hurungNo power supply; incorrect wiring; blown fuseCheck power connections; verify wiring; replace fuse if necessary (by qualified personnel)
Maca suhu anu salahSensor fault; incorrect input type setting; wiring errorCheck sensor and wiring; verify input type configuration in settings
Output not switchingOutput wiring error; control mode issue; relay failureVerify output wiring; check control mode and setpoint; test relay (by qualified personnel)
Unstable controlIncorrect PID tuning parameters; sensor noiseRetune PID parameters; check sensor for noise or interference

7. Spésifikasi

8. Garansi jeung Rojongan

Red Lion Controls products are warranted against defects in material and workmanship for a specified period from the date of purchase. For detailed warranty terms and conditions, please refer to the official Red Lion Controls websitus atanapi ngahubungan rojongan customer maranéhanana.

For technical assistance, troubleshooting, or service inquiries, please visit the Red Lion Controls official website or contact their authorized distributors. Provide your product model number (PXU10020) and serial number when seeking support.

Dokumén Patali - PXU10020

Praview Red Lion PAX Series 1/8 DIN Analog Input Panel Meters User Manual
User manual and technical datasheet for Red Lion PAX series 1/8 DIN analog input panel meters (PAXD, PAXP, PAXH, PAXS, PAXT). Covers specifications, installation, wiring, programming, and troubleshooting for industrial automation.
Praview Red Lion PXU Series Temperature and Process Controllers Hardware Guide
This hardware guide provides comprehensive information on the Red Lion PXU Series Temperature/Process Controllers, including installation, wiring, programming, and specifications for firmware version 1.5 or above.
Praview Red Lion CUB5 Miniatur Elektronik 8-Digit Penghitung Ganda sareng Indikator Laju
Detailed specifications, installation guide, and programming manual for the Red Lion CUB5 miniature electronic 8-digit dual counter and rate indicator. Features include selectable LCD or LED backlighting, optional relay and serial communication modules, and NEMA 4X/IP65 sealing.
Praview Red Lion PAX Series 1/8 DIN Analog Input Panel Meters - User Manual
Comprehensive user manual for the Red Lion PAX Series 1/8 DIN Analog Input Panel Meters, covering specifications, installation, wiring, programming, troubleshooting, and option cards for models PAXD, PAXP, PAXS, PAXT, and PAXH.
Praview Timer DIN Seri 1/16 Red Lion C48T - Modél Preset Tunggal sareng Ganda
Detailed technical specifications, features, programming, and ordering information for the Red Lion C48T Series 1/16 DIN single and dual preset timers, including models C48TS and C48TD. This document covers display options, power requirements, input/output specifications, certifications, environmental conditions, programming modes, and ordering details.
Praview Red Lion CL01 Paradigm 2x20 LCD Operator Interface Terminal Manual
Technical manual and specifications for the Red Lion CL01 Paradigm 2x20 LCD Operator Interface Terminal, covering features, installation, safety, and troubleshooting.