1. Bubuka
This manual provides essential information for the safe and efficient operation of your Dometic DSP 412 Sine Power Inverter. The DSP 412 converts 12V DC battery power into 230V AC pure sinusoidal output, making it suitable for sensitive electronic devices. Please read these instructions carefully before installation and use, and keep them for future reference.
2. Parentah Kasalametan
Failure to observe these warnings could result in serious injury or damage to the product. Always prioritize safety.
- Bahaya listrik: Ulah muka inverter casing. Henteu aya bagian anu tiasa dilayanan ku pangguna di jero. Rujuk sadayana jasa ka tanaga anu mumpuni.
- Ventilasi: Ensure adequate ventilation around the inverter. Do not block ventilation openings. Overheating can cause damage or fire.
- Uap: Do not expose the inverter to rain, moisture, or excessive humidity.
- Bahan anu gampang kaduruk: Do not install or operate the inverter near flammable materials or in environments with explosive gases.
- Wiring anu leres: Connect the inverter only to a 12V DC power source. Observe correct polarity (+ to + and - to -) to prevent damage. Use appropriate cable gauges for the power connections.
- Kapasitas beban: Do not exceed the inverter's maximum output wattage of 350W. Overloading can trigger automatic shutdown or damage the unit.
3. Produk Langkungview
The Dometic DSP 412 Sine Power Inverter is designed to provide reliable AC power on the go. It features a compact design and robust construction.

Gambar 1: Hareupeun view of the Dometic DSP 412 Sine Power Inverter, showing the main unit with attached red and black power cables. The front panel includes an ON/OFF switch, a STATUS indicator light, and USB ports.

Gambar 2: Tukangeun view of the Dometic DSP 412 Sine Power Inverter, highlighting the cooling fan for heat dissipation and the connection point for the power cables.

Gambar 3: The Dometic DSP 412 Sine Power Inverter shown alongside its metal mounting plate and screws, illustrating the easy mounting system for secure installation.
4. Setup jeung Instalasi
Proper installation is crucial for the inverter's performance and safety.
- Pamasangan: Utilize the provided mounting plate and screws to secure the inverter in a stable, well-ventilated location. Ensure the mounting surface can support the inverter's weight and that there is sufficient space for airflow around the unit.
- Sumber Daya: Connect the inverter's red cable to the positive (+) terminal of a 12V DC battery and the black cable to the negative (-) terminal. Ensure connections are tight and secure. The wide DC input voltage range makes it ideal for Euro 6 compliant vehicles.
- Grounding: For safety, ensure the inverter is properly grounded according to local electrical codes.
- Cék awal: Before connecting any devices, double-check all connections for correct polarity and tightness.
5. Parentah Operasi
Follow these steps to operate your Dometic DSP 412 Inverter:
- Daya Hurung: Flip the ON/OFF switch to the 'ON' position. The STATUS indicator light will illuminate, indicating the inverter is active.
- Sambungkeun Alat: Plug your 230V AC devices into the inverter's output socket. Ensure the total wattage alat disambungkeun teu ngaleuwihan 350W.
- Modeu Hemat Énergi: The inverter features an energy-saving mode with an automatic 'wake-up' function. If no load or a very low load is detected, the inverter may enter a low-power state to conserve battery. It will automatically 'wake up' when a sufficient load is connected.
- Pareum listrik: When finished, disconnect all devices and flip the ON/OFF switch to the 'OFF' position.
6. Pangropéa
Pangropéa rutin ngajamin kinerja optimal sareng umur panjang inverter anjeun.
- beberesih: Bersihkeun bagian luar inverter sacara berkala nganggo lawon anu garing sareng lemes. Entong nganggo pembersih cair atanapi pelarut.
- Ventilasi: Ensure the ventilation openings are free from dust and debris. Use compressed air to clear any blockages if necessary.
- Sambungan: Regularly check all electrical connections (battery terminals, output sockets) to ensure they are tight and free from corrosion.
- Panyimpenan: Upami nyimpen inverter kanggo waktos anu lami, pegatkeun tina batréna teras simpen di tempat anu tiis sareng garing.
7. Cara ngungkulan
Bagian ieu ngabahas masalah umum anu anjeun tingali.
- Taya Kaluaran Daya:
- Check if the inverter is switched 'ON'.
- Verify battery connections are secure and correct.
- Ensure the 12V battery has sufficient charge.
- Inverter Shuts Down:
- The inverter features automatic restart after overload, over-voltage, or under-voltage kaayaan.
- Overload: Disconnect some devices to reduce the load below 350W.
- Leuwih / Dina Voltage: Pariksa vol batrétage. Ensure it is within the inverter's operating range.
- Overheating: Ensure adequate ventilation. Allow the inverter to cool down.
- STATUS Indicator Light Flashing: Refer to the specific error codes in the full product manual (if available) or contact support. Generally, flashing indicates a fault condition.
If problems persist after following these steps, contact Dometic customer support.
8. Spésifikasi
| Fitur | Spésifikasi |
|---|---|
| merek | Dométik |
| Nomer modél | 9600002541 |
| Daya Kaluaran (Kontinyu) | 350 Watt |
| Masukan Voltage | 12 volt DC |
| Kaluaran Voltage | 230 Volts AC (Pure Sine Wave) |
| Dimensi produk | 21 x 12.7 x 5.2 cm |
| Item Beurat | 1.2 kg |
| Total outlet kakuatan | 1 |
| Komponén Kaasup | Power inverter, Mounting hardware |
9. Garansi jeung Rojongan
For warranty information, technical support, or service inquiries, please contact Dometic customer service. Keep your purchase receipt as proof of purchase.