1. Bubuka
This manual provides detailed instructions for the installation, operation, and maintenance of the Intermatic WH-40 Electromechanical Water Heater Timer. This device is designed to automatically control your water heater's operation based on a preset daily schedule, helping to manage energy consumption.
The Intermatic WH-40 is a double-pole, 10000 Watts (40 Amp) maximum, 250 Volt - 60 Hz time switch. It is UL Listed 885L.

Gambar 1: Hareupeun view of the Intermatic WH-40 Electromechanical Water Heater Timer. The timer features a grey metal casing with 'The Little Gray Box' and 'Electric Water Heater Timer by Intermatic' branding. It has an ON/OFF switch and a small window for viewing the internal mechanism.
2. Émbaran Kasalametan
WARNING: Risk of electric shock. Always disconnect power at the main electrical panel before installing, servicing, or performing any work on this switch or the water heater it controls. Failure to do so may result in serious injury or death.
- Ensure all wiring is performed by a qualified electrician and complies with all local and national electrical codes.
- Do not connect aluminum wires to the switch terminals. Use copper conductors only.
- Ensure the timer is properly grounded.
- Do not remove the internal insulator during wiring; replace it securely after wiring is complete.
3. Pamasangan
Installation of the WH-40 timer involves mounting the unit and connecting it to your water heater's electrical circuit. Refer to the wiring diagram and instructions carefully.

Gambar 2: Internal label of the Intermatic WH-40 timer, showing the wiring diagram, operational instructions, and safety warnings. This label is crucial for correct installation and programming.
3.1 Pamasangan
The timer is designed for wall mounting. Use appropriate fasteners to secure the timer to a sturdy surface. The back of the unit features mounting holes for this purpose.

Gambar 3: Pungkur sareng sisi view of the Intermatic WH-40 timer, illustrating the mounting holes and the robust metal casing.
3.2 Kabel
Before proceeding, ensure power is disconnected at the main electrical panel.
- Open the timer cover to access the wiring terminals and internal components.
- Refer to the wiring diagram provided on the internal label (Figure 2) and inside the timer (Figure 4).
- Connect the incoming power lines (LINE 1, LINE 2) to the designated terminals.
- Connect the water heater load wires to the LOAD terminals.
- Connect the Neutral (white, if present) and Ground (green or bare) wires as indicated in the diagram.
- penting: Clock motor leads are prewired to terminals 1 & 3. Do not alter these connections.
- Pastikeun sadaya sambungan kedap tur aman.
- Do not remove the internal insulator during wiring; replace it securely after wiring is complete.

Gambar 4: The Intermatic WH-40 timer with its cover open, revealing the yellow clock dial, manual lever, and wiring terminals. The internal caution regarding aluminum wires is visible.
4. Operasi
The WH-40 timer operates by using a clock dial and adjustable trippers to set ON and OFF times for your water heater.
4.1 Setting the Program
- Set ON/OFF Trippers: Mount the silver (ON) trippers at the times you wish the water heater to start operating. Place the black (OFF) trippers at the times you want the water heater to turn off. Fasten the trippers to the dial by pushing them against the edge of the dial, then tightening the screws firmly with your fingers.
- Setel Waktos Ayeuna: Lembut BETOT the clock dial out (towards you) and turn it in either direction until the correct time-of-day (the current time when the switch is being put into operation) is directly under the TIME POINTER. Do not move the time pointer itself.
- Close the Time Switch cover, ensuring it is latched and locked securely.

Gambar 5: Pahareup-hareup view of the yellow clock dial with time markings (AM/PM), the central time pointer, and the manual ON/OFF lever. Trippers would be attached to the outer edge of the dial.
4.2 Manual Override
The external manual lever allows you to temporarily turn the water heater ON or OFF ahead of its scheduled program. The time switch will resume its preset program at the next scheduled ON or OFF operation.
Catetan: The manual lever is inoperative for 15 minutes immediately after an automatic operation (when the timer itself has just switched ON or OFF).
4.3 After a Power Failure
If there is a power failure, or if the water heater was disconnected at the main panel, you must reset the clock dial to the proper time-of-day as described in Section 4.1, step 2.
4.4 Suspending Automatic Operation
To suspend the automatic operation of the timer, remove all ON and OFF trippers from the dial. You can then use the manual lever to control the water heater as desired.
5. Pangropéa
The Intermatic WH-40 timer is designed for reliable, long-term operation with minimal maintenance.
- Periodically inspect the timer for any signs of damage or wear.
- Ensure the cover is securely closed and latched.
- Keep the timer clean and free from dust and debris.
- If any wiring connections appear loose or corroded, disconnect power at the main panel and have a qualified electrician inspect and tighten them.
6. Cara ngungkulan
If your Intermatic WH-40 timer is not functioning as expected, consider the following:
- Timer not turning ON/OFF at scheduled times:
- Check if the ON/OFF trippers are correctly installed and securely fastened on the dial.
- Verify that the clock dial is set to the correct time-of-day.
- Ensure the manual lever is not overriding the automatic program.
- Water heater not receiving power:
- Confirm that power is supplied to the timer from the main electrical panel.
- Check all wiring connections for tightness and proper contact (after disconnecting power).
- Ensure the internal insulator is correctly in place.
- Timer motor not running:
- Verify power supply to the timer.
- If the motor is not running despite power, the unit may require professional inspection or replacement.
For issues not resolved by these steps, contact a qualified electrician or Intermatic customer support.
7. Spésifikasi
- Jumlah modél: WH-40
- Modeu operasi: Otomatis
- Jenis Kontak: Biasana Buka
- Tipe Panyambung: Colokkeun
- Tipe Terminal: sekrup
- Jenis sirkuit: 1-jalan
- Tipe Aktuator: Pencét Tombol
- Bahan Hubungan: Tambaga
- Peunteun Perlindungan Internasional: IP5X
- Métode kontrol: Toél
- Pabrikan: Intermatik
- Ukuran Paket: 10 x 10 x 10 inci
- Beurat barang: 1.02 pon
8. Émbaran jaminan
Specific warranty details for the Intermatic WH-40 Electromechanical Water Heater Timer are typically provided with the product packaging or can be obtained directly from the manufacturer. Please refer to the documentation included with your purchase or visit the official Intermatic websitus pikeun kawijakan jaminan panganyarna.
9. Rojongan Palanggan
For technical assistance, replacement parts, or further inquiries regarding your Intermatic WH-40 timer, please contact Intermatic customer support. Contact information can usually be found on the product packaging or their official websitus.