1. Bubuka
This manual provides detailed instructions for the proper use, setup, operation, and maintenance of your OWON VDS1022I USB PC Oscilloscope. Please read this manual thoroughly before operating the device to ensure optimal performance and safety. The OWON VDS1022I is a compact, high-performance USB oscilloscope designed for various electrical measurement and analysis tasks, featuring USB isolation for enhanced signal integrity and PC protection.
2. Produk Langkungview
2.1 Eusi pakét
Upon unpacking, verify that all items listed below are present and in good condition. If any items are missing or damaged, contact your supplier.

Image: The OWON VDS1022I USB PC Oscilloscope, two oscilloscope probes, a USB cable, a software CD, and a quick guide manual are included in the package.
- OWON VDS1022I USB PC Oscilloscope Unit
- Kabel USB
- Probe Osiloskop (2 unit)
- CD parangkat lunak
- Pitunjuk Gancang
2.2 Fitur konci
- Up to 25MHz bandwidth and 100MS/s real-time samplaju le.
- 5K record length for detailed waveform capture.
- Friendly user interface with FFT, X-Y mode, and dual waveform display.
- Multiple trigger options: edge, video, slope, pulse, and alternate.
- USB isolation for reduced signal interference and enhanced PC protection.
- USB bus powering, eliminating the need for an external power adapter.
- Compact and ultra-thin body design for easy portability.
2.3 Tata Tata Alat
Familiarize yourself with the various ports and indicators on the oscilloscope unit.

Gambar: Sisi view of the OWON VDS1022I, highlighting the USB Port, Probe Compensation output (5V 1KHz), MULTI Port, Signal Input of Channel 2 (CH2), and Signal Input of Channel 1 (CH1).
- Port USB: Connects to your PC for data transfer and power.
- Probe Compensation (5V 1KHz): Output for adjusting probe compensation.
- MULTI Port: Multi-function port for additional capabilities.
- CH2 (Channel 2): Signal input for the second channel.
- CH1 (Channel 1): Signal input for the first channel.

Gambar: Luhur jeung handap views of the OWON VDS1022I. The bottom view shows the "Isolation" label, indicating the USB isolation feature.
The device features USB isolation, which helps to reduce noise and protect your computer from potential electrical surges from the measurement circuit.
3. Setup Guide
3.1 Pamasangan parangkat lunak
- Selapkeun CD parangkat lunak anu disayogikeun kana drive CD-ROM komputer anjeun.
- Locate and run the setup executable file. Follow the on-screen instructions to install the OWON oscilloscope software and necessary drivers.
- Alternatively, download the latest software and drivers from the official OWON website. Ensure you select the correct model (VDS1022I) and operating system.
- During installation, ensure that the oscilloscope is NOT connected to the PC until prompted, or until the software installation is complete. This helps ensure proper driver recognition.
3.2 Connecting the Oscilloscope
- Connect one end of the supplied USB cable to the USB port on the OWON VDS1022I unit.
- Connect the other end of the USB cable to an available USB port on your PC. The device is bus-powered, so no external power adapter is required.
- Your operating system should detect the device and, if drivers were installed correctly, recognize it as an OWON VDS1022I oscilloscope.
3.3 Sambungan Probe sareng Kompensasi
- Connect the oscilloscope probes to the CH1 and CH2 input BNC connectors on the device.
- Attach the probe ground clip to a known ground point in your circuit.
- To compensate the probe, connect the probe tip to the 5V 1KHz Probe Compensation output.
- Adjust the compensation screw on the probe body until a flat-top square wave is displayed on the software interface. This ensures accurate signal representation.
4. Parentah Operasi
4.1 Launching the Software
After successful installation and connection, launch the OWON oscilloscope application from your desktop shortcut or Start Menu. The software interface will display the waveform acquisition window.
4.2 Tampilan Gelombang Dasar
- Skala Vertikal (Volt/Div): Adjust the vertical sensitivity for each channel using the controls in the software. This determines the voltage represented by each vertical division on the display.
- Skala Horisontal (Waktos/Div): Adjust the horizontal time base to control the time represented by each horizontal division. This affects the displayed duration of the waveform.
- Gandeng Input: Select DC, AC, or GND coupling for each channel as needed.
- DC: Displays both AC and DC components of the signal.
- AC: Blocks the DC component, displaying only the AC component.
- GND: Disconnects the input signal, displaying a ground reference line.
4.3 Nyimbulkeun
Triggering stabilizes repetitive waveforms and captures single-shot events. The VDS1022I supports various trigger modes:
- Edge Trigger: Triggers on a rising or falling edge of the input signal at a specified voltage tingkat.
- Video Trigger: Triggers on standard video signals.
- Slope Trigger: Triggers on a signal's rise or fall time.
- Pulse Trigger: Triggers on pulses of specific width.
- Alternate Trigger: Allows triggering on two different channels alternately.
Adjust the trigger level and mode within the software to achieve a stable waveform display.
4.4 Pangukuran sareng Analisis
- Pangukuran otomatis: The software provides automatic measurements for parameters like Vpp, Vmax, Vmin, Freq, Period, RMS, etc. Select desired measurements from the menu.
- Kursor: Paké voltage and time cursors to manually measure specific points on the waveform.
- FFT (Fast Fourier Transform): Access the FFT function to analyze the frequency components of your signal.
- Mode XY: Display the relationship between two signals in X-Y format, useful for phase comparisons or Lissajous figures.
5. Pangropéa
- beberesih: Use a soft, dry cloth to clean the exterior of the oscilloscope. For stubborn dirt, a slightly damp lawon anu dieusi deterjen hampang tiasa dianggo, pikeun mastikeun teu aya cairan anu asup kana alat.
- Panyimpenan: Simpen alat dina tempat anu tiis sareng garing jauh tina sinar panonpoé langsung sareng suhu anu ekstrim.
- Perawatan Probe: Ati-ati dina nanganan probe. Ulah ngabengkokkeun atanapi neken kabel kaleuleuwihi. Jaga ujung probe tetep bersih.
- Apdet parangkat lunak: Periodically check the OWON websitus pikeun apdet parangkat lunak sareng firmware pikeun mastikeun kinerja anu optimal sareng aksés kana fitur-fitur énggal.
6. Cara ngungkulan
6.1 Device Not Recognized by PC
- Ensure the USB cable is securely connected to both the oscilloscope and the PC.
- Verify that the correct drivers have been installed. Reinstall drivers if necessary, following the instructions in Section 3.1.
- Coba sambungkeun ka port USB anu béda dina PC anjeun.
- Balikan deui komputer anjeun sareng cobian deui.
6.2 No Waveform Display or Unstable Waveform
- Check probe connections to the device and the circuit under test. Ensure ground clips are properly connected.
- Verify that the input coupling (DC/AC/GND) is set appropriately for your signal.
- Adjust the vertical (Volts/Div) and horizontal (Time/Div) scales to match the expected signal characteristics.
- Adjust the trigger level and trigger mode. An unstable waveform often indicates an incorrect trigger setting.
- Pastikeun sumber sinyal aktip sareng ngahasilkeun sinyal dina rentang pangukuran osiloskop.
6.3 Software Issues or Crashes
- Ensure your operating system meets the minimum requirements for the OWON software.
- Update the software to the latest version from the OWON websitus.
- Tutup aplikasi nu nungtut lianna nu bisa jadi ngonsumsi sumber daya sistem.
- If issues persist, try reinstalling the software.
6.4 Limited Bandwidth or Signal Distortion
- The VDS1022I has a 25MHz bandwidth. Signals exceeding this frequency may be attenuated or distorted.
- Ensure probes are correctly compensated (refer to Section 3.3).
- For high-frequency measurements, ensure proper grounding and minimize cable lengths to reduce noise.
7. Spésifikasi

Image: Dimensions of the OWON VDS1022I oscilloscope, showing approximate measurements of 180mm (7.09in) length, 125mm (4.92in) width, and 23mm (0.91in) thickness.
| Parameter | Nilai |
|---|---|
| Bandwidth | 25 MHz |
| Saluran | 2 + 1 (external trigger) |
| Sample Laju | 100 MS/s (real-time) |
| Horizontal Scale (s/div) | 5 ns/div ~ 100 s/div (1-2-5 step) |
| Naek Waktos | ≤ 14 ns |
| Rékam Panjang | 5K points |
| Masukan Gandeng | DC, AC, GND |
| Input impedansi | 1 MΩ ±2%, in parallel with 10 pF ±5 pF |
| Channels Isolation | 50Hz: 100:1, 10MHz: 40:1 |
| Max Input Voltage | 400V (PK - PK) (DC+AC, PK - PK) |
| DC Keuntungan Akurasi | ± 3% |
| Probe Atenuasi Faktor | 1X, 10X, 100X, 1000X |
| LF Respond (AC, -3dB) | ≥ 5Hz (at input, AC coupling, -3dB) |
| Sampling Rate / Relay Time Akurasi | 150 ps |
| Interpolasi | sin(x) / x |
| Resolusi nangtung (A/D) | 8 bit (2 saluran sakaligus) |
| Sensitipitas nangtung | 5 mV/div ~ 5 V/div |
| Antarbeungeut Komunikasi | USB 1.1 (isolation) |
| Dimensi produk | 6.69 x 4.72 x 0.71 inches (170 x 120 x 18 mm); 1.46 Pounds (0.66 kg) |
| Produsén | OWON |
8. Garansi jeung Rojongan
OWON products are designed and manufactured to high-quality standards. For specific warranty information, please refer to the warranty card included with your product or visit the official OWON website. In case of technical issues, questions, or service requests, please contact OWON customer support through their official channels. Keep your purchase receipt as proof of purchase for warranty claims.