Elitech LogEt 8 THE

Elitech LogEt 8 THE Digital Suhu jeung Kalembaban Data Logger Manual Instruksi

Model: LogEt 8 THE

1. Produk Langkungview

The Elitech LogEt 8 THE is a reusable digital data logger designed for monitoring temperature and humidity. It is suitable for various applications, including cold chain management for pharmaceuticals, vaccines, food, and other sensitive products. This device features high precision sensors, multiple alarm thresholds, and direct USB connectivity for data download and report generation.

Elitech LogEt 8 THE Digital Temperature and Humidity Data Logger with external probe

Image: Elitech LogEt 8 THE Digital Temperature and Humidity Data Logger with its external probe. The device displays "32.9" and has "START" and "STOP" buttons.

2. Fitur konci

  • High-precision Temperature & Humidity Sensor: Wide temperature range from -40°F to 185°F with ±0.5°F accuracy. Humidity measuring range: 10%RH to 90%RH, with ±3%RH accuracy.
  • Sababaraha Alarm: Configurable with up to 5 alarm thresholds (3 high, 2 low).
  • Plug and Read Functionality: Direct USB connection for data download without requiring a separate cable or reader.
  • Automatic PDF Report Generation: Encrypted PDF reports are automatically generated with password protection. Free Elitechlog software provides personalized settings and management.
  • Kahirupan Gawé Panjang: Utilizes a replaceable lithium battery for extended operation.

3. Komponén Alat

Diagram of Elitech LogEt 8 THE components

Image: Diagram illustrating the components of the Elitech LogEt 8 THE data logger. Key components include: 1. USB Port, 2. LCD Screen, 3. Buttons (START/STOP), 4. External Temperature and Humidity Sensor, and 5. Battery Cover.

  1. Port USB: Used for connecting to a computer for data download and configuration.
  2. Layar LCD: Displays current temperature, humidity, and device status.
  3. Tombol: "START" button to initiate logging, "STOP" button to cease logging.
  4. Sénsor Suhu sareng Kalembaban éksternal: Provides accurate environmental readings.
  5. Panutup batré: Protects the replaceable lithium battery compartment.

4. Setélan

4.1 Inspeksi Awal

Upon receiving your LogEt 8 THE data logger, inspect the packaging and device for any signs of damage. Ensure all included components (data logger, calibration certificate, user manual) are present.

4.2 Pamasangan parangkat lunak

Before first use, download and install the Elitechlog software from the official Elitech website. This software is required for device configuration, data download, and report generation.

  • Visit the Elitech official websitus.
  • Navigate to the support or download section.
  • Download the Elitechlog software compatible with your operating system (Windows/macOS).
  • Turutan pitunjuk dina layar pikeun ngarengsekeun pamasangan.
Elitech LogEt 8 THE connected to a laptop for data export

Image: The Elitech LogEt 8 THE data logger plugged into a laptop's USB port, illustrating the data export process via ElitechLogWin software to PDF, Excel, or TXT formats.

4.3 Konfigurasi Alat

Connect the data logger to your computer via the USB port. The Elitechlog software will detect the device. Use the software to configure parameters such as:

  • Interval logging
  • Mimitian reureuh
  • Alarm thresholds (high/low temperature and humidity)
  • Unit suhu (°C/°F)
  • Zona waktu

Ensure the external temperature and humidity sensor is securely connected to the device before deployment.

5. Operasi

5.1 Starting Data Logging

Pencét jeung tahan tombol MULAI button for approximately 3 seconds until the "REC" indicator appears on the LCD screen. This indicates that the device has begun recording data according to the configured settings.

5.2 Stopping Data Logging

Pikeun ngeureunkeun log, pencét sareng tahan tombol EUREUN button for approximately 3 seconds. The "REC" indicator will disappear from the LCD screen, confirming that logging has ceased.

5.3 Reading Data and Generating Reports

After logging is complete, connect the data logger to a computer via the USB port. The Elitechlog software will automatically recognize the device and prompt you to download the recorded data. The software will then generate an encrypted PDF report, which can also be exported to Excel or TXT formats for further analysis.

Elitech LogEt 8 THE generating a PDF report

Image: A visual representation of the Elitech LogEt 8 THE data logger connected to a computer, showing the generation of a PDF report. The report includes a graph of temperature and humidity data over time.

5.4 Perlindungan Sandi

The generated PDF reports can be password-protected for enhanced data security. This feature is configured within the Elitechlog software.

6. Pangropéa

6.1 Ngagantian batré

The LogEt 8 THE uses a replaceable lithium battery. When the battery indicator on the LCD screen shows low power, replace the battery to ensure continuous and accurate operation. To replace the battery:

  1. Locate the battery cover (Component 5 in the diagram).
  2. Buka tutup batré kalayan ati-ati.
  3. Remove the old battery and insert a new compatible lithium battery, observing polarity.
  4. Tutup panutup batre aman.

6.2 beberesih

Wipe the device clean with a soft, dry cloth. Avoid using abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is dry before use.

6.3 Panyimpenan

When not in use for extended periods, store the data logger in a cool, dry place away from direct sunlight and extreme temperatures. Remove the battery if storing for very long durations to prevent leakage.

7. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Alat teu hurung.Batré lemah atawa béak.Ganti batréna.
Data teu kacatet.Logging not initiated or stopped prematurely.Pastikeun MULAI button was pressed and held until "REC" appears. Check battery level.
Cannot connect to computer/software.USB connection issue; software not installed or outdated.Ensure the device is fully inserted into the USB port. Verify Elitechlog software installation and update to the latest version. Try a different USB port.
Bacaan teu akurat.Sensor obstruction or damage; device placed in extreme conditions.Ensure the external sensor is clean and unobstructed. Relocate the device to a suitable environment within its operating range.
PDF report not generated.Software error; insufficient disk space.Restart the Elitechlog software and try again. Ensure sufficient storage space on your computer.

8. Spésifikasi

FiturRincian
Nomer modélLogEt 8 THE
Rentang Suhu-40°F nepi ka 185°F (-40°C nepi ka 85°C)
Akurasi Suhu± 0.5 ° F (± 0.3 ° C)
Range Kelembapan10% RH dugi ka 90% RH
Akurasi asor± 3% RH
Kapasitas Rékam16000 titik
KonektipitasUSB
Format LaporanPDF (automatic, encrypted), Excel, TXT
Sumber Daya1 Lithium Metal battery (included, replaceable)
Dimensi produk4 x 1.8 x 0.8 inci
Beurat3.17 ons
Komponén KaasupData Logger, Calibration Certificate, User Manual
Elitech LogEt 8 THE temperature and humidity range

Image: The Elitech LogEt 8 THE data logger displaying its temperature range from -40°C/-40°F to 85°C/185°F and indicating a 16000 points record capacity.

9. Garansi jeung Rojongan

Elitech provides US Technician Support via Email and Phone for any inquiries or issues you may encounter with your LogEt 8 THE data logger. Please refer to the official Elitech website or the included documentation for specific warranty terms and contact information.

For technical assistance, please visit the Elitech official websitus atanapi ngahubungi tim dukunganana sacara langsung.

Dokumén Patali - LogEt 8 THE

Praview Elitech LogEt 5 Series Data Logger Specifications and User Manual
Comprehensive specifications, features, and operating instructions for the Elitech LogEt 5 series of temperature and humidity data loggers, designed for cold chain monitoring.
Praview Elitech LogEt 1 Series Single-Use PDF Data Logger User Manual
User manual for the Elitech LogEt 1, LogEt 1TH, and LogEt 1Bio single-use PDF data loggers, covering appearance, technical specifications, indication instructions, and operation.
Praview Elitech LogEt 8 Series Data Logger User Manual - Temperature and Humidity Monitoring
Comprehensive user manual for the Elitech LogEt 8 Series data loggers, detailing specifications, operation, installation, and troubleshooting for temperature and humidity monitoring in cold chain logistics.
Praview Elitech LogEt 260 Series Instruction Manual - Temperature, Light, Vibration Data Loggers
Comprehensive instruction manual for the Elitech LogEt 260 series data loggers, covering safety, product features, selection, technical parameters, operation, and LED indicators. Features temperature, light, vibration monitoring, and 4G connectivity.
Praview Elitech LogEt 5 Series User Manual: Temperature and Humidity Data Loggers
Comprehensive user manual for the Elitech LogEt 5 Series temperature and humidity data loggers. Covers overview, model selection, specifications, operation, status indication, battery replacement, and default configurations.
Praview Elitech LogEt 1 Series User Manual: Temperature and Humidity Data Loggers
Comprehensive user manual for the Elitech LogEt 1 series of single-use data loggers, covering LogEt 1 (temperature), LogEt 1TH (temperature-humidity), and LogEt 1 Bio (high accuracy temperature). Includes specifications, operation, status indication, and warnings.