Oakton WD-35805-18

Oakton WD-35805-18 Spear-Tip Double-Junction pH Electrode

Instruksi Manual

1. Bubuka

The Oakton WD-35805-18 Spear-Tip Double-Junction pH Electrode is a specialized sensor designed for accurate pH measurements in various applications, particularly those involving semi-solid samples. Its unique spear-tip design allows for direct penetration into materials like food, soil, or gels, while the double-junction construction minimizes contamination of the reference electrolyte, ensuring stable and reliable readings. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your electrode.

2. Produk Langkungview

The WD-35805-18 electrode features a robust glass body and a sealed, double-junction reference system. The spear-tip sensing bulb is specifically engineered for direct insertion into challenging samples. This design provides a faster response time and improved longevity compared to conventional electrodes when used with semi-solids.

Oakton WD-35805-18 Spear-Tip Double-Junction pH Electrode

Image of the Oakton WD-35805-18 pH electrode, showing its spear-tip design, glass body, and the 'OAKTON' branding. The electrode is designed for direct insertion into semi-solid samples.

3. Setélan

  1. Initial Conditioning: Before first use, or after prolonged storage, soak the electrode tip in a pH 4 or pH 7 buffer solution for at least 30 minutes. This rehydrates the glass bulb and ensures optimal performance.
  2. Sambungan: Connect the electrode's BNC connector to a compatible pH meter. Ensure the connection is secure and dry.
  3. Kalibrasi: Calibrate the pH meter with the electrode using at least two fresh pH buffer solutions (e.g., pH 4.01, 7.00, and 10.00). Follow the specific calibration procedure outlined in your pH meter's instruction manual. Always calibrate at the temperature of your samples for best accuracy.

4. Parentah Operasi

  1. Sample Persiapan: For semi-solid samples, ensure the sample is homogenous. If necessary, prepare the sample by gently mixing or grinding to achieve consistency.
  2. pangukuran:
    • Rinse the electrode with distilled or deionized water and gently blot dry with a lint-free tissue.
    • Carefully insert the spear-tip of the electrode directly into the semi-solid sample. Ensure the entire sensing bulb and junction are fully immersed.
    • Allow sufficient time for the reading to stabilize on your pH meter. This may take longer in viscous or low-ionic strength samples.
    • Record the stable pH reading.
  3. Between Samples: Rinse the electrode thoroughly with distilled or deionized water between each measurement to prevent cross-contamination.

5. Pangropéa

  • beberesih:
    • After each use, rinse the electrode thoroughly with distilled or deionized water.
    • For stubborn deposits (e.g., protein, grease), refer to your pH meter's manual or electrode manufacturer's guidelines for specific cleaning solutions. Avoid abrasive materials.
  • Panyimpenan: Always store the electrode with its sensing bulb immersed in a proper electrode storage solution (e.g., Oakton electrode storage solution or a pH 4 buffer with KCl). moal pernah store the electrode dry or in distilled/deionized water, as this will dehydrate the glass bulb and deplete the reference electrolyte.
  • Frékuénsi Calibration: The frequency of calibration depends on the accuracy required, the nature of the samples, and the frequency of use. For best results, calibrate daily or before each series of measurements.

6. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Bacaan anu teu stabil atanapi ngalayangDehydrated bulb, dirty electrode, air bubbles, temperature fluctuations, insufficient sample immersion.Recondition electrode, clean electrode, ensure proper immersion, allow sample to equilibrate to temperature.
Waktu Réspon LambatDirty or clogged junction, dehydrated bulb, old electrode.Clean electrode, recondition, consider electrode replacement if old.
Inaccurate Readings / Calibration FailureContaminated buffers, incorrect calibration procedure, damaged electrode, temperature difference.Use fresh buffers, re-calibrate carefully, inspect electrode for damage, ensure temperature consistency.

If issues persist after attempting these solutions, contact Oakton technical support.

7. Spésifikasi

  • model: WD-35805-18
  • Jenis éléktroda: Spear-Tip Double-Junction pH Electrode
  • Bahan awak: Kaca
  • Junction Type: Annular
  • Aplikasi idéal: Semi-solid samples (e.g., food, soil, gels)
  • Pabrikan: Oakton
  • ASIN: B07QL2H8CF

8. Garansi jeung Rojongan

For detailed warranty information and technical support, please refer to the official documentation provided with your purchase or visit the Oakton website. Contact information for customer service and technical assistance can typically be found on the manufacturer's product page or in the packaging materials.

Dokumén Patali - WD-35805-18

Praview Timer OAKTON 410 kalayan Alarm: Pitunjuk Operasi sareng Spésifikasi
Pitunjuk operasi sareng spésifikasi anu lengkep pikeun Timer OAKTON 410 sareng Alarm (Modél WD-35002-00), anu ngajelaskeun fitur-fiturna, fungsi tombol, modeu timing, sareng setélan alarm.
Praview OAKTON TEMP TC Acorn Series Thermocouple Thermometer Operating Instructions
Operating instructions and specifications for the OAKTON TEMP TC Acorn Series Thermocouple Thermometer, including details on measurement, calibration, troubleshooting, and accessories.
Praview Méter OAKTON ION Acorn Series: Pitunjuk sareng Panduan Operasi
Manual operasi lengkep pikeun Méter pH/Ion OAKTON ION 5 sareng ION 6 Seri Acorn. Ngawengku setelan, kalibrasi, pangukuran, pangropéa, sareng ngungkulan masalah pikeun analisis kualitas cai anu akurat.
Praview Stopwatch OAKTON Acara Tunggal 220 kalayan Pitunjuk Operasi Alarm
Pitunjuk operasi anu lengkep pikeun Stopwatch OAKTON Single-Event 220 sareng Alarm (Modél WD-35002-10), anu ngawengku fungsi stopwatch, setélan waktos/kalender, fitur alarm, spésifikasi, sareng inpormasi garansi.
Praview Oakton DO250 / DO260 Leyur Oksigén Méter Instruksi Manual
Manual instruksi komprehensif pikeun Oakton DO250 jeung DO260 Méter Oksigén Leyur, ngawengku produk leuwihview, operasi dasar, calibration, manajemén data, setelan, pangropéa, ngungkulan, sarta precautions kaamanan.
Praview OAKTON 300 Series Handheld Water Quality Meters Instruction Manual
This instruction manual provides comprehensive guidance for operating the OAKTON 300 series handheld water quality meters. It covers product overview, setup, calibration, measurement, data management, maintenance, and troubleshooting for accurate water quality analysis.