1. Bubuka
This manual provides comprehensive instructions for the installation, operation, and maintenance of your Intermatic ET2145CP Electronic Timer. This device is designed for 24-hour and 365-day operation, capable of handling up to 30 Amps at 120 to 277Vac. Please read this manual thoroughly before installation and use to ensure safe and proper functionality.
2. Émbaran Kasalametan penting
PERHATOSAN: Résiko Seuneu atanapi Setrum Listrik
- Pegatkeun sambungan kakuatan dina circuit breaker (s) atawa pegatkeun sambungan switch (es) saméméh masang atawa ngalayanan.
- Langkung ti hiji pemutus sirkuit atanapi saklar pegatkeun tiasa diperyogikeun pikeun nyéépkeun énergi sateuacan ngalayanan.
- Pamasangan sareng / atanapi kabel kedah saluyu sareng sarat kode listrik nasional sareng lokal.
- Paké TAMBAGA conductors ONLY.
- Do TEU remove the insulator covering the terminals.

3. Produk Langkungview
The Intermatic ET2145CP Electronic Timer features a clear digital display and intuitive controls for programming. Key components include:
- Digital tampilan: Shows current time, date, and programming information.
- Tombol MODE: Used to cycle through different programming modes (e.g., time setting, event programming).
- ENTER/NEXT Button: Confirms selections and advances to the next setting.
- Tombol ON/OFF: Used for manual override or to set ON/OFF times for programmed events.
- CLEAR MEM Button: Clears all programmed events or settings.
- CLEAR ENTRY Button: Clears the current entry during programming.
- Panah luhur/handap: Adjust values (time, date, event numbers).
- Blok Terminal: For electrical wiring connections.
4. Parentah instalasi
Follow these steps for proper installation of the Intermatic ET2145CP Electronic Timer:
- Pegatkeun daya: Before beginning any work, ensure all power to the circuit is disconnected at the main circuit breaker or disconnect switch. Verify with a voltage panguji.
- Terminal Kabel Aksés: To access the wiring terminals, lift the plastic insulator covering the terminals. You may need to remove a screw and swing the insulator aside.
- Sambungan Wiring: Connect the electrical wiring to the appropriate terminals. Ensure all connections are secure and comply with local and national electrical codes. Use only copper conductors.
- Secure Insulator: Once wiring is complete, replace the plastic insulator covering the terminals and secure it with the screw (if applicable).
- Mulangkeun Daya: After ensuring all connections are correct and secure, restore power to the circuit.
5. Parentah Operasi
5.1. Setelan Awal: Nyetél Waktos sareng Tanggal
- Pencét éta MODÉ button until the time/date setting option appears on the display.
- Ngagunakeun éta Panah luhur/handap to adjust the current hour. Press Asupkeun / salajengna pikeun mastikeun.
- Repeat for minutes, AM/PM (if applicable), year, month, and day.
- Pencét MODÉ pikeun kaluar tina ménu setting.
5.2. Programming ON/OFF Events
The timer supports multiple ON/OFF events. Refer to the display for available program slots.
- Pencét éta MODÉ button until 'PROGRAM' or 'EVENT' mode is displayed.
- Ngagunakeun éta Panah luhur/handap to select an event number (e.g., 1 ON, 1 OFF). Press Asupkeun / salajengna.
- Set the desired ON time using the Panah luhur/handap jeung Asupkeun / salajengna.
- Set the desired OFF time using the Panah luhur/handap jeung Asupkeun / salajengna.
- Select the days of the week for this event to be active (e.g., Mon-Fri, Daily, Weekends). Press Asupkeun / salajengna.
- Repeat for additional events as needed.
- Pencét MODÉ pikeun kaluar programming.
5.3. Manual Override
To temporarily override the programmed schedule:
- Pencét salah sahiji ON/OFF buttons to manually switch the output ON or OFF.
- The timer will typically revert to its programmed schedule at the next scheduled event.
5.4. Clearing Memory
To clear all programmed events or reset the timer:
- Pencét jeung tahan tombol CLEAR MEM button for a few seconds until the display confirms memory clear.
- Alternatipna, nganggo CLEAR ENTRY button to clear individual entries during programming.
6. Pangropéa
The Intermatic ET2145CP Electronic Timer requires minimal maintenance. Ensure the unit is kept clean and free from dust and debris. Do not attempt to open the casing or repair the internal components, as there are no user-serviceable parts inside. For cleaning, use a soft, dry cloth. Avoid abrasive cleaners or solvents.
7. Cara ngungkulan
If you encounter issues with your timer, consider the following common troubleshooting steps:
- Taya Témbongkeun / Taya Daya: Check the circuit breaker or fuse supplying power to the timer. Ensure all wiring connections are secure.
- Timer Not Switching: Verify that the programmed events are correctly set and enabled. Check if the manual override is active.
- Lepat Waktos/Tanggal: Re-enter the correct time and date as per Section 5.1.
- Paripolah Anu Teu Teratur: A power surge or interruption might cause erratic behavior. Try resetting the timer by pressing the CLEAR MEM button (this will erase all programs, requiring re-programming).
If problems persist after attempting these steps, contact Intermatic customer support for assistance.
8. Spésifikasi Téknis
| Spésifikasi | Nilai |
|---|---|
| Nomer Modél Item | ET2145CP |
| merek | Intermatik |
| Modeu Operasi | 24 Hr. / 365 Days |
| Amps | 30 |
| Voltage | 120 nepi ka 277Vac |
| Bahan | palastik |
| Dimensi produk | 4 "D x 6.5" W x 10" H |
| Item Beurat | 2.25 pon |
| Produsén | Intermatik |
9. Garansi sarta Rojongan Palanggan
For information regarding the product warranty, please refer to the warranty card included with your purchase or visit the official Intermatic website. For technical assistance, troubleshooting, or to inquire about replacement parts, please contact Intermatic customer support directly. Contact details can typically be found on the manufacturer's websitus atanapi bungkusan produk.





