1. Produk Langkungview

The Hayward W3T-Cell-3 TurboCell Salt Chlorination Cell is designed for in-ground swimming pools up to 15,000 gallons. It provides naturally sanitized water, reducing the need for traditional chlorine methods and offering a more comfortable swimming experience.

Hayward W3T-Cell-3 TurboCell Salt Chlorination Cell

Image: The Hayward W3T-Cell-3 TurboCell Salt Chlorination Cell, a key component for pool sanitization.

Fitur konci:

  • Delivers silky smooth, naturally sanitized water that won’t irritate eyes, dry out skin, or cause fabrics to fade.
  • Reduces chlorine costs by up to 50%.
  • Independently certified by the National Sanitation Foundation (NSF) for reliable performance.
  • Compatible with Hayward AquaRite, AquaRite Pro, SwimPure Plus salt chlorination systems.
  • Compatible with Hayward OmniLogic, OmniHub, ProLogic, and AquaPlus automation and control systems.

2. Setup jeung Instalasi

Proper installation is crucial for the optimal performance and longevity of your TurboCell. Always ensure the pool pump is off and power to the chlorinator is disconnected before beginning installation.

2.1 Pancegahan Kasalametan

  • Always disconnect power to the pool pump and chlorinator before handling the salt cell.
  • Ensure proper ventilation if working with chemicals.
  • Anggo alat pelindung pribadi (PPE) anu cocog sapertos sarung tangan sareng panyalindungan panon.

2.2 Léngkah-léngkah Instalasi

  1. Pareuman Daya: Disconnect power to the pool pump and the salt chlorination system at the circuit breaker.
  2. Unplug Salt Cell: Unplug the salt cell connector from the chlorinator control unit.
  3. Cai solokan: Open the strainer lid on the pool pump to allow air into the system, helping to drain water from the salt cell for easier removal.
  4. Remove Old Cell: Loosen the unions on both ends of the existing salt cell and carefully remove it from the plumbing.
  5. Pasang Sél Anyar: Position the new Hayward W3T-Cell-3 TurboCell, ensuring the water flow indicator on the cell aligns with the direction of water flow in your plumbing.
  6. Kencangkeun sambungan: Securely tighten the unions on both ends of the salt cell to prevent leaks.
  7. Sambungkeun deui Daya: Plug the salt cell connector back into the chlorinator control unit. Close the strainer lid on the pump.
  8. Mulangkeun Daya: Turn on the pool pump and the salt chlorination system at the circuit breaker.
  9. Check Salt Levels: After powering on, press the "Diagnostics" button on your chlorinator to check the salt level readings. The system will calibrate, and the correct reading should appear.
Hayward W3T-Cell-3 TurboCell Salt Chlorination Cell Front View

Gambar: Hareupeun view of the Hayward W3T-Cell-3 TurboCell Salt Chlorination Cell, showing its design and connections.

Hayward W3T-Cell-3 Dimensions Diagram

Image: Diagram illustrating the dimensions (length, height, width, cord length, weight) of the Hayward W3T-Cell-3 TurboCell.

Video: Official Hayward video demonstrating the installation process and how the salt chlorination system works.

3. Operasi

The Hayward TurboCell works by converting salt in your pool water into chlorine, providing continuous sanitization. This process is managed by your compatible Hayward chlorination or automation system.

3.1 How Salt Chlorination Works

  1. Pool salt (NaCl) is added to the water.
  2. Water dissolves salt into a low, teardrop-level salinity.
  3. The chlorinator adjusts chlorine production for perfect balance.
  4. The salt conversion cell turns salt into chlorine gas (Cl₂).
  5. Chlorine gas (Cl₂) reacts with pool water to form a sanitizing compound (HOCl).
How Hayward Salt Systems Work Diagram

Image: Diagram illustrating the five-step process of how Hayward salt chlorination systems convert salt into chlorine for pool sanitization.

Video: Official Hayward video explaining the operational principles of the AquaRite salt chlorination system.

Natural Sanitization with Hayward TurboCell

Image: Illustrates the natural sanitization process, creating a virtually endless supply of chlorine from salt.

4. Pangropéa

Regular maintenance ensures the longevity and efficiency of your TurboCell. Inspect and clean the cell every 3 months or as needed.

4.1 Cleaning the Salt Cell

  1. Pegatkeun Daya: Turn off the chlorinator and pool pump, and unplug the salt cell.
  2. Remove Cell: Remove the salt cell from the plumbing as described in the installation steps.
  3. Nyiapkeun solusi beberesih: Use a salt cell cleaning holder (if available) or a suitable container. Fill the cell with a solution of 1/3 muriatic acid and 2/3 clean water.
  4. Soak: Allow the cell to soak for approximately 15 minutes to dissolve mineral deposits on the titanium plates. Do not exceed 15 minutes to avoid damage.
  5. Bilas: Pour out the cleaning solution and thoroughly rinse the salt cell with clean water.
  6. Pasang deui: Reinstall the cleaned salt cell into the plumbing, ensuring secure connections. Reconnect the salt cell plug and restore power to the system.

Catetan: Always follow safety guidelines when handling muriatic acid. Refer to your chlorinator's manual for specific cleaning instructions and recommended pool chemistry levels.

5. Cara ngungkulan

If your Hayward W3T-Cell-3 TurboCell is not performing as expected, consult the following common issues and solutions:

MasalahMungkin Cukang lantarananaSolusi
Kaluaran klorin rendahLow salt level, dirty cell, low water flow, chlorinator output setting too low.Check and adjust salt level. Clean the salt cell. Ensure adequate water flow. Increase chlorinator output percentage.
"Check Salt" Light OnTingkat uyah handap 2600 ppm.Add salt to the pool. Allow 24 hours for salt to dissolve and recheck.
"High Salt" Light OnSalt level above 3400 ppm.Partially drain pool water and add fresh water. Recheck salt level.
"Inspect Cell" Light OnCell efficiency is greatly reduced, or cell needs cleaning/replacement.Inspect and clean the cell. If problem persists, the cell may need replacement.
"No Flow" Light OnInsufficient water flow through the cell.Check pump, filter, and valves for obstructions. Ensure pump is running.

For detailed diagnostic codes and advanced troubleshooting, refer to your specific Hayward chlorinator control unit's manual.

6. Spésifikasi

FiturRincian
merekHayward
Nomer modélW3T-CELL-3
Kapasitas kolam renangNepi ka 15,000 galon
Item Beurat3.5 pon
Dimensi produk11.7 x 5.6 x 3.8 inci
UPC610377388238
KasaluyuanHayward AquaRite, AquaRite Pro, SwimPure Plus, OmniLogic, OmniHub, ProLogic, AquaPlus systems.

7. Rojongan

For further assistance, technical support, or warranty inquiries, please contact Hayward customer service. You can also visit the official Hayward websitus pikeun sumberdaya tambahan sarta informasi produk.

  • Hayward Websitus: hayward.com
  • Palayanan palanggan: Refer to your product packaging or the Hayward websitus pikeun inpo kontak panganyarna.

Dokumén Patali - W3T-CELL-3

Praview Hayward T-CELL-3 GLX-CELL-3-W Instalasi jeung Operasi Guide
Pituduh ieu nyayogikeun pitunjuk pikeun masang sareng ngonpigurasikeun sél klorinator uyah Hayward T-CELL-3 sareng GLX-CELL-3-W sareng sistem kolam Hayward anu cocog. Pituduh ieu ngawengku inpormasi kasaluyuan, prosedur sambungan léngkah-léngkah pikeun modél AQR, AQR-PRO, PL-P-4, sareng PL-PS-x, sareng inpormasi operasional penting ngeunaan siklus filtrasi sareng laju aliran.
Praview Hayward TurboCell S3 Salt Chlorinator Cell: Configuration and Compatibility Guide
Learn how to configure and ensure compatibility for Hayward TurboCell S3 salt chlorinator cells with various Hayward pool systems. Includes cross-reference tables and important operational information.
Praview Hayward TCELL925/TCELL925-W: Setup and Operation Guide
Guide for configuring Hayward TCELL925 and TCELL925-W salt chlorinator cells with AquaRite, AquaRite Pro, and ProLogic pool systems. Covers menu settings, compatibility, and important operational information.
Praview Hayward OmniLogic HLBASE Installation Manual: Automation and Chlorination
Comprehensive installation manual for the Hayward OmniLogic HLBASE system, covering automation and chlorination for pools and spas. Includes setup, wiring, plumbing, and configuration guidance.
Praview Hayward Salt & Swim Cell SAS-CELL Installation and Calibration Guide
Step-by-step instructions for installing and calibrating the Hayward Salt & Swim SAS-CELL for your swimming pool, including replacement procedures and troubleshooting tips.
Praview Hayward AquaRite + Owner's Manual
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Hayward AquaRite + salt chlorinator system for swimming pools. It covers safety precautions, system configuration, water chemistry, troubleshooting, and servicing.