1. Bubuka
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the ABB ACS580-01-026A-4 Drive. This industrial drive is designed for various applications requiring precise motor control, offering a robust solution for 400V systems with an 11KW power rating and 25A current capacity, housed in an IP21 rated frame size R2.
Please read this manual thoroughly before attempting any installation or operation to ensure proper functionality and to prevent damage to the equipment or injury to personnel.
2. Émbaran Kasalametan
PERHATOSAN: Electrical shock hazard. Only qualified personnel should perform installation, commissioning, and maintenance of this equipment. Disconnect all power before servicing.
- Pastikeun drive sareng motorna dipasang dina taneuh anu leres.
- Do not operate the drive with damaged cables or components.
- Salawasna turutan kode listrik lokal jeung nasional.
- Lindungi drive tina kalembaban, lebu, sareng suhu anu ekstrim.
3. Setup jeung Instalasi
The ABB ACS580-01-026A-4 Drive is designed for DIN Rail mounting. Ensure adequate ventilation around the unit.
3.1. Pamasangan
Mount the drive vertically on a DIN rail in an enclosure that provides the specified IP21 protection. Allow sufficient clearance for cooling air flow above and below the unit.

Gambar 3.1: Hareupeun view of the ABB ACS580-01-026A-4 Drive, showing its compact design and control panel area. This image illustrates the overall physical appearance of the drive unit.
3.2. Kabel
Connect the main power supply (400V AC) to the designated input terminals. Connect the motor to the output terminals. Ensure all connections are secure and correctly phased. Refer to the wiring diagram provided with the drive for detailed terminal assignments.
- Input kakuatan: L1, L2, L3 (400V AC)
- Kaluaran motor: U, V, W
- Grounding: Connect to protective earth (PE) terminal.
- Kontrol kabel: Connect control signals (e.g., start/stop, speed reference) as per application requirements.
4. Parentah Operasi
Once installed and wired, the drive can be configured and operated. The ACS580 series features an intuitive control panel for parameter setting and monitoring.
4.1. Mimiti Power-Up
- Pariksa yén sadaya sambungan kabel parantos leres sareng aman.
- Apply main power to the drive. The control panel should illuminate.
- Follow the quick setup wizard on the control panel to configure basic motor parameters (e.g., motor nominal voltage, current, frequency, speed).
4.2. Operasi dasar
- Mimitian / eureun: Use the designated control input (e.g., digital input) or the control panel buttons to start and stop the motor.
- Kontrol laju: Adjust the motor speed using the analog input, fieldbus, or control panel potentiometer, depending on configuration.
- Ngawaskeun: The control panel displays operational data such as motor speed, current, voltage, sareng kodeu kasalahan.
5. Pangropéa
Regular maintenance ensures the longevity and reliable operation of the ABB ACS580-01-026A-4 Drive.
- beberesih: Periodically clean the drive's exterior and cooling fins to prevent dust accumulation, which can impede heat dissipation. Use a soft, dry cloth.
- Pariksa kipas: Inspect the cooling fan for proper operation and cleanliness. Replace if noisy or not functioning correctly.
- Pariksa sambungan: Annually, or as needed, verify that all electrical connections are tight and free from corrosion.
- Kaayaan Lingkungan: Pastikeun lingkungan operasi tetep dina kisaran suhu sareng kalembaban anu ditangtukeun.
6. Cara ngungkulan
This section provides guidance for common issues encountered during the operation of the drive.
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Drive teu tiasa dihurungkeun | No input power; Blown fuse; Incorrect wiring | Check main power supply; Inspect fuses; Verify wiring connections. |
| Motor teu hurung | Control signal missing; Parameter misconfiguration; Motor fault | Check control wiring; Review drive parameters; Inspect motor for issues. |
| Kasalahan overcurrent | Motor overload; Short circuit in motor/cables; Incorrect acceleration time | Reduce load; Check motor and cables; Increase acceleration time. |
| Overvoltage kasalahan | Input tinggi voltage; Regenerative braking without braking resistor | Pariksa input voltage; Install braking resistor if needed. |
For detailed fault codes and advanced troubleshooting, refer to the complete technical manual available on the ABB website or contact ABB technical support.
7. Spésifikasi
Key technical specifications for the ABB ACS580-01-026A-4 Drive:
- Jumlah modél: ACS580-01-026A 4
- merek: BUAH ARA
- Masukan Voltage: 400V AC
- Peunteun kakuatan: 11 KW
- Peunteun ayeuna: 25 Amps
- Peunteun IP: IP21
- Ukuran pigura: R2
- Tipe Pamasangan: DIN Rail Gunung
- Pabrikan: ABB drive
8. Garansi jeung Rojongan
This ABB drive comes with a standard manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official ABB websitus.
For technical support, service, or spare parts, please contact your local ABB representative or visit the ABB support portal: