Trane VAL12000

Trane VAL12000 OEM Thermostatic Expansion Valve

model: VAL12000 / VAL-12000

merek: Trane

1. Produk Langkungview

The Trane VAL12000 / VAL-12000 is an Original Equipment Manufacturer (OEM) thermostatic expansion valve designed for use in various Trane chiller systems. This component plays a crucial role in the refrigeration cycle by controlling the amount of refrigerant flowing into the evaporator, ensuring efficient heat exchange and system performance.

It is a direct replacement for or supersedes models VAL-12000, VAL012000, VAL08573, VAL-8573, and VAL8573.

Jalan Komponen OEM Traneamp

Figure 1: Illustrative stamp indicating Trane OEM Component. Actual product appearance may vary.

Commonly Used In:

  • Various Trane Chillers: Rotary Chillers, RTAC Chillers, BCVC Chillers
  • Specific Rotary Chiller Models: RTAC120, RTAC135, RTAC140, and others.

2. Spésifikasi

ProdusénTrane
Nomer BagianVAL12000
Nomer Modél ItemVAL12000
Tipe klepThermostatic Expansion Valve (TXV)
Sambungan1.387 ODS (Outlet Diameter Size) x 2.125 OD (Overall Diameter); M12 Input
Item BeuratKurang leuwih 5 pon
Item Paket Kuantitas1
ASINB07ZWHPJS6
Tanggal Kahiji Sadia1 Nopémber 2019

Note: Specifications are subject to change without notice. Always refer to the product label for the most accurate information.

3. Pedoman instalasi

Installation of the Trane VAL12000 expansion valve should only be performed by qualified HVAC technicians. Improper installation can lead to system malfunction, refrigerant leaks, and potential safety hazards. Always follow industry best practices and local codes.

3.1 Pancegahan Kasalametan

  • Ensure the system is de-energized and depressurized before beginning any work.
  • Wear appropriate Personal Protective Equipment (PPE), including safety glasses and gloves.
  • Handle refrigerants with care, following all safety guidelines.
  • Pastikeun ventilasi anu leres di daérah damel.

3.2 Léngkah-léngkah Pamasangan (Umum)

  1. Persiapan Sistim: Isolate the section of the refrigeration system where the valve is to be installed. Recover any refrigerant according to environmental regulations.
  2. Leupaskeun Old Valve: Carefully disconnect and remove the existing expansion valve, noting its orientation and connections.
  3. Nyiapkeun Klep Anyar: Inspect the new VAL12000 valve for any damage. Ensure all connection points are clean and free of debris.
  4. Sambungkeun klep: Install the new valve, ensuring proper alignment and secure connections. Use appropriate brazing or flaring techniques as required by the system design. Pay close attention to the M12 input and ODS connections.
  5. Thermal Bulb Placement: Securely attach the thermal bulb to the suction line in the correct location, typically just after the evaporator outlet, ensuring good thermal contact. Insulate the bulb to prevent ambient temperature interference.
  6. Cek Bocor: After installation, perform a thorough leak check using an appropriate leak detection method.
  7. Evakuasi sareng Ngisi Daya: Evacuate the system to a deep vacuum to remove non-condensables and moisture. Recharge the system with the correct type and amount of refrigerant as specified by the chiller manufacturer.
  8. Sistem ngamimitian: Slowly bring the system back online and monitor its performance to ensure proper operation of the expansion valve.

For detailed, system-specific installation instructions, refer to the service manual of the Trane chiller unit in which this valve is being installed.

4. Operasi

The Trane VAL12000 is a thermostatic expansion valve (TXV) that automatically regulates the flow of liquid refrigerant into the evaporator based on the superheat of the refrigerant vapor leaving the evaporator. Its primary function is to maintain a constant superheat, ensuring the evaporator is fully utilized without allowing liquid refrigerant to return to the compressor.

The thermal bulb, sensing the temperature of the suction line, transmits pressure to the diaphragm within the valve. This pressure, balanced against the evaporator pressure and spring pressure, modulates the valve's opening. This dynamic control optimizes system efficiency and protects the compressor from liquid slugging.

5. Pangropéa

The Trane VAL12000 expansion valve is a robust component designed for long-term reliability. While it generally requires minimal direct maintenance, its optimal performance is dependent on the overall health and cleanliness of the refrigeration system.

5.1 Recommended Practices

  • Kabersihan Sistim: Ensure the refrigeration system remains free of contaminants (moisture, acids, debris) which can cause corrosion or blockages within the valve. Regular filter dryer replacement is crucial.
  • Refrigerant Quality: Use only the specified type and quality of refrigerant.
  • Pangimeutan Kinerja: Periodically monitor system superheat and subcooling. Deviations can indicate issues with the expansion valve or other system components.
  • Deteksi bocor: Regularly check for refrigerant leaks around valve connections.

Any adjustments or repairs to the expansion valve or refrigeration system should be performed by certified HVAC professionals.

6. Cara ngungkulan

Troubleshooting issues related to an expansion valve often involves diagnosing overall system performance. The following are common symptoms that might indicate an issue with the expansion valve, though they can also be caused by other system components.

GejalaPossible Cause (Valve Related)Aksi
Panas Super Tinggi / Tekanan Sedot LeutikValve restricted or stuck closed; thermal bulb lost charge or improperly installed.Check thermal bulb contact and insulation. Inspect valve for blockages. Consider valve replacement if faulty.
Low Superheat / High Suction Pressure (Flooding)Valve stuck open; thermal bulb improperly installed or sensing incorrect temperature.Verify thermal bulb placement. Check for external bulb damage. Consider valve replacement if faulty.
Fluctuating Suction Pressure / SuperheatIntermittent valve operation; moisture in system causing ice formation at valve orifice.Check for system contaminants. Replace filter dryer. Evacuate and recharge system.
Kompresor Short CyclingImproper refrigerant flow due to valve issue, leading to low pressure cutout.Diagnose refrigerant charge and valve operation.

penting: Troubleshooting refrigeration systems requires specialized knowledge and tools. Always consult with or hire a qualified HVAC technician for diagnosis and repair.

7. Garansi jeung Rojongan

As an OEM component, the Trane VAL12000 expansion valve is typically covered under the warranty terms provided by Trane for their chiller systems or by the distributor from whom it was purchased. Specific warranty details, including duration and coverage, may vary.

For warranty claims, technical support, or to order replacement parts (such as MOD02686 for a stepper motor or MOD02688 for a cable, if applicable to your system), please contact your authorized Trane distributor or a certified HVAC service provider.

Pabrikan: Trane

Kontak: Refer to your local Trane representative or the official Trane website for service and support information.

Dokumén Patali - VAL12000

Praview Trane Quality Parts and Solutions Catalog | HVAC Components
Explore Trane's comprehensive catalog of HVAC parts and solutions, featuring compressors, controls, filters, motors, and accessories. Expert advice, immediate availability, and fast delivery from Ingersoll Rand.
Praview Trane RTWD / RTUD R'newal Service Program Kit Parentah Instalasi
Parentah instalasi pikeun Kit Program Service Trane R'newal pikeun RTWD na RTUD Chillers, detailing lokasi bagian, warnings kaamanan, masalah lingkungan, sarta breakdowns komponén.
Praview Trane Komprehensif Chilled-Cai System Desain Katalog
Katalog komprehensif Trane pikeun ngarancang sistem cai tiis canggih. Pituduh ieu ngajéntrékeun komponén sistem, prinsip desain canggih, konfigurasi, sareng kriteria pilihan pikeun chillers, menara pendingin, pompa, sareng klep kontrol. Éta museurkeun kana ngahontal efisiensi, réliabilitas, sareng éféktivitas biaya dina aplikasi HVAC komérsial sareng industri, kalebet wawasan ngeunaan Tracer Chiller Plant Control and Trane Design Assist.
Praview Parentah Instalasi Trane AFDR Retrofit pikeun RTHD Chillers
Pituduh pamasangan komprehensif pikeun Trane AFDR Retrofit Air-cooled Adaptive Frequency Drive™ pikeun RTHD Chillers. Nyertakeun kaamanan, kaayaan lingkungan, rinci modél, sareng léngkah-léngkah prosedur pamasangan pikeun tanaga anu mumpuni.
Praview Parentah Instalasi Trane Ignitor KIT03033USA
Parentah instalasi lengkep pikeun Trane Ignitor KIT03033USA, ngawengku warnings kaamanan, pertimbangan lingkungan, jeung step-demi-step prosedur pikeun tanaga mumpuni.
Praview Trane Air-Fi™ Wireless Communications Sensor (WCS) Pituduh Rujukan Gancang
Pituduh ieu nyadiakeun inpormasi rujukan gancang pikeun Sensor Komunikasi Nirkabel Trane Air-Fi™ (WCS), ngawincik cara nyaluyukeun suhu kamar, setelan sistem, laju kipas, ngatur pangeusian, jeung ngarti kodeu kasalahan. Éta kalebet peringatan kaamanan sareng indikator umur batre.