ProCom PCS150T-1-AW

ProCom Dual Fuel Ventless Gas Fireplace System with Mantle

Model: PCS150T-1-AW | Brand: ProCom

Bubuka

This manual provides detailed instructions for the safe installation, operation, and maintenance of your ProCom Dual Fuel Ventless Gas Fireplace System with Mantle. This system is designed to operate efficiently using either Natural Gas (NG) or Liquid Propane (LP) and features a thermostat control for consistent heating. Please read all instructions carefully before installation and use.

ProCom Dual Fuel Ventless Gas Fireplace System with Mantle, Antique White

Gambar: Hareupeun view of the ProCom Dual Fuel Ventless Gas Fireplace System in Antique White, showcasing the mantle and the firebox with realistic logs and flames.

Émbaran Kasalametan

PERHATOSAN: Pamasangan, panyesuaian, parobahan, palayanan, atanapi pangropéa anu teu leres tiasa nyababkeun tatu atanapi karusakan harta. Tingal manual ieu. Pikeun pitulung atanapi inpo tambahan, konsultasi hiji installer mumpuni, agénsi jasa, atawa supplier gas.

Setup sareng Instalasi

Ngabongkar sareng Inspeksi

Carefully remove all components from the packaging. Inspect for any shipping damage. If any damage is found, contact your retailer immediately. Ensure all parts listed in the "What's in the Box" section are present.

Majelis

Some assembly is required for the mantle and the fireplace insert. Refer to the general assembly instructions provided with the product. Ensure the fireplace insert is securely placed within the mantle.

ProCom Fireplace System installed in a living room

Image: The ProCom fireplace system integrated into a living room setting, demonstrating its aesthetic appeal.

Fuel Type Selection (Dual Fuel Technology)

This fireplace system is designed for use with either Natural Gas (NG) or Liquid Propane (LP). It is crucial to select the correct fuel type and ensure the appliance is configured accordingly before connecting to a gas supply.

penting: Conversion between NG and LP must be performed by a qualified service technician. Incorrect conversion can lead to unsafe operation and void the warranty.

Gas inlet ports for Natural Gas (NG) and Liquid Propane (LP) with blue cap

Image: Close-up of the gas inlet ports, labeled NG (Natural Gas) and LP (Liquid Propane), showing the blue cap for LP. This indicates the current configuration or the port for LP connection.

Gas inlet ports for Natural Gas (NG) and Liquid Propane (LP) with yellow and blue caps

Image: Close-up of the gas inlet ports, labeled NG (Natural Gas) and LP (Liquid Propane), showing both yellow and blue caps. This illustrates the dual fuel capability and the distinct caps for each gas type.

Sambungan Gas

Connect the fireplace to the appropriate gas supply (Natural Gas or Liquid Propane) using approved gas connectors and fittings. Ensure all connections are tight and leak-free. A gas pressure test must be performed by a qualified technician.

Parentah Operasi

Mimitian Mimiti

  1. Pastikeun klep suplai gas kabuka.
  2. Press and hold the control knob (refer to image below) to the "PILOT" position.
  3. While holding the knob, press the Piezo ignitor button repeatedly until the pilot flame ignites.
  4. Continue to hold the control knob for approximately 30-60 seconds after the pilot ignites to allow the thermocouple to heat up.
  5. Release the control knob. If the pilot flame extinguishes, repeat steps 2-4.
Control knob for pilot and temperature settings, and Piezo ignitor button

Image: Close-up of the control panel showing the main control knob with settings for "OFF", "PILOT", and numbered temperature settings (1-5), alongside the Piezo ignitor button.

Thermostat Control Operation

Once the pilot is lit, turn the control knob to the desired temperature setting (1-5). The thermostat will automatically cycle the main burner on and off to maintain the set room temperature. Setting 1 is the lowest heat output, and setting 5 is the highest.

Shutting Down the Fireplace

  1. To turn off the main burner, turn the control knob to the "PILOT" position. The pilot flame will remain lit.
  2. To completely turn off the fireplace, turn the control knob to the "OFF" position. This will extinguish both the main burner and the pilot flame.
  3. Pikeun waktos anu lami teu dianggo, disarankeun pikeun nutup klep suplai gas utama.

Pangropéa

beberesih umum

Log Set Care

The ceramic fiber logs are designed for durability. Handle them carefully to avoid breakage. Do not rearrange the logs from their factory-set positions, as this can affect flame appearance and efficiency.

Inspeksi taunan

It is recommended to have the fireplace inspected annually by a qualified service technician to ensure proper operation and safety.

Pamérésan masalah

MasalahMungkin Cukang lantarananaSolusi
Pilot moal hurung
  • Teu aya suplai bénsin
  • Hawa dina garis gas
  • Pilot orifice clogged
  • Ignitor teu sparking
  • Ensure gas valve is open
  • Bleed air from line (consult technician)
  • Clean pilot orifice (consult technician)
  • Check ignitor wire connection, replace battery if applicable
Pilot lights but main burner will not ignite
  • Control knob not set to a temperature setting
  • Thermocouple not heating properly
  • ODS system activated
  • Turn control knob to a numbered setting
  • Hold pilot knob longer, ensure pilot flame engulfs thermocouple
  • Ensure adequate ventilation, clear any obstructions
Fireplace produces odors
  • Alat anyar nu kaduruk
  • Dust or debris on burner
  • Operate at high setting for several hours (ensure ventilation)
  • Clean burner area (consult technician)

If troubleshooting steps do not resolve the issue, contact a qualified service technician or ProCom customer support.

spésifikasi

FiturRincian
merekProCom
Ngaran modélBahan Bakar Dual
Nomer Modél ItemPCS150T-1-AW
Kaluaran Panas15,000 British Thermal Units (BTU)
Panutup pemanasanNepi ka 600 sq.
Tipe SuluhGas Alam (NG) atanapi Propana Cair (LP)
Efisiensi99.9% Vent Free
Tipe KontrolKontrol termostat
Tipe IgnitionBattery-assisted Piezo ignition
Fitur KasalametanSénsor Pangurangan Oksigén (ODS)
Dimensi produk12.5 "D x 28" W x 36.5" H
Item Beurat84.5 pon
BahanWood (mantle), Concrete (logs)
WarnaBodas antik
Komponén KaasupBurner, Log Set, Mantel
Majelis DiperlukeunYes (General assembly instructions provided)

Émbaran jaminan

This ProCom Dual Fuel Ventless Gas Fireplace System is covered by a 1 Taun Garansi kawates. For specific terms and conditions, please refer to the warranty documentation included with your product or contact ProCom customer support.

Rojongan Palanggan

For technical assistance, parts, or warranty claims, please contact ProCom customer support. Have your model number (PCS150T-1-AW) and purchase date available when contacting support.

Pabrikan: ProCom

Refer to the product packaging or the official ProCom websitus pikeun inpo kontak panganyarna.

Dokumén Patali - PCS150T-1-AW

Praview Procom NEW PRO-9900 AM / FM Citizens Band 2-Way Radio Pamaké Manual
Buku pituduh pikeun Procom NEW PRO-9900 AM/FM Citizens Band 2-Way Radio, ngajéntrékeun pungsi, operasi, fitur, jeung spésifikasi téknis pikeun pamakéan optimal.
Praview PROCOM Atlas Loud Mouth Digital Wireless Intercom User Manual
This user manual provides comprehensive information on the PROCOM Atlas Loud Mouth Digital Wireless Intercom, including its features, operation, specifications, safety guidelines, and FCC compliance.
Praview Factory Buys Direct FDLT24/30-1 Vent-Free Gas Log Chassis Owner's Operation and Installation Manual
Comprehensive guide for the Factory Buys Direct FDLT24/30-1 Vent-Free Gas Log Chassis, covering installation, operation, safety precautions, maintenance, and troubleshooting for dual fuel thermostat models.
Praview Duluth Forge Vented Pitunjuk Instalasi Log Gas Alam
Pituduh instalasi komprehensif pikeun Duluth Forge vented gas alam set log, model FNL18L103B, FN24L103B, sarta FN30L103B. Nyertakeun kaamanan, panempatan log, operasi, curing, sareng bagian. Disatujuan pikeun standar ANSI Z21.11.2 na Z21.60.
Praview Duluth Forge FDLR24/30-1 Dual Fuel-Free Gas Log Chassis Manual Operasi sareng Pamasangan Pamilik
Manual komprehensif ieu nyadiakeun parentah lengkep pikeun operasi sarta pamasangan Duluth Forge FDLR24 / 30-1 Dual Suluh curhat-Free Gas Log Chassis. Ieu nyertakeun pancegahan kaamanan, spésifikasi, prosedur instalasi, parentah operasi, ngungkulan masalah, ngagantian bagian, sarta informasi jaminan.
Praview Duluth Forge Vented Natural Gas Logs: Installation, Operation, and Safety Manual
Comprehensive guide for Duluth Forge Vented Natural Gas Logs (Models FNVL18-1, FNVL24-1, FNVL30-1). Includes installation instructions, operating procedures, safety warnings, maintenance tips, troubleshooting, parts lists, and warranty information.