Morris 94164

User Manual: 94164, 3/0 x 5/16" x 1" Copper SB 2-Hole Compression Lug

Merek: Morris

1. Produk Langkungview

The Morris 94164 Copper SB 2-Hole Compression Lug is a high-quality electrical connector designed for secure and reliable termination of copper conductors. This lug features a seamless barrel for optimal crimping and two bolt holes for robust mechanical and electrical connection to bus bars, panels, or other electrical components. It is suitable for heavy-duty applications requiring durable and efficient power transmission.

Morris 94164 Copper SB 2-Hole Compression Lug

An image of the Morris 94164 Copper SB 2-Hole Compression Lug, showing its copper construction, two bolt holes, and the barrel for conductor insertion. The lug appears silver due to plating or lighting, with blue markings indicating UL listing.

2. Émbaran Kasalametan

Always adhere to local electrical codes and safety regulations when working with electrical components. Failure to do so may result in serious injury or property damage.

3. Instalasi (Setup)

Proper installation is crucial for the long-term performance and safety of the electrical connection. Use a high-quality crimping tool specifically designed for copper compression lugs.

Alat anu diperyogikeun:

Léngkah-léngkah pamasangan:

  1. Prepare the Conductor: Strip the insulation from the copper conductor to the length specified by the lug's barrel depth. Ensure the stripped end is clean and free of nicks or burrs.
  2. Clean the Conductor: Use a wire brush or abrasive pad to remove any oxidation from the stripped copper conductor.
  3. Selapkeun konduktor: Insert the cleaned conductor fully into the lug barrel until it bottoms out.
  4. Crimp the Lug: Using the correct die size for 3/0 AWG, perform the required number of crimps according to the crimping tool manufacturer's instructions. Ensure each crimp is complete and secure.
  5. Pariksa Crimp: Visually inspect the crimped connection for proper deformation and secure attachment.
  6. Aman ka Surface: Align the two bolt holes of the lug with the corresponding holes on the bus bar or connection point. Insert appropriate bolts and washers.
  7. Bolts torsi: Tighten the bolts to the manufacturer's recommended torque specifications using a torque wrench to ensure a secure and low-resistance electrical connection.

4. Fungsi jeung Operasi

Once properly installed, the Morris 94164 Compression Lug provides a permanent, low-resistance electrical connection between a 3/0 AWG copper conductor and an electrical component. Its robust design ensures efficient current flow and mechanical stability under various operating conditions. The lug is designed to maintain its integrity and conductivity over its service life, provided it is installed correctly and not subjected to conditions beyond its specified ratings.

5. Pangropéa

Regular inspection of electrical connections is recommended to ensure continued safety and performance.

6. Cara ngungkulan

Common issues related to compression lugs are typically due to improper installation or environmental factors.

MasalahMungkin Cukang lantarananaSolusi
Overheating at connection pointLoose bolt connection, improper crimp, undersized lug for current.Ensure bolts are torqued correctly. Re-crimp or replace lug if crimp is faulty. Verify lug sizing.
Corrosion on lug surfaceExposure to moisture or corrosive agents.Clean the surface. Consider environmental protection (e.g., heat shrink tubing) for future.
Conductor pulls out of lugInsufficient crimps, incorrect die size, improper crimping tool.Replace lug and re-crimp using correct tools and procedures.

7. Spésifikasi

Key technical specifications for the Morris 94164 Copper SB 2-Hole Compression Lug:

AtributRincian
Nomer modél94164
Ukuran konduktor3/0 AWG Copper
Bolt Hole Size5/16 inci
Jarak Tengah-ka-Tengah1 inci
BahanTambaga
TipeSB 2-Hole Compression Lug
ProdusénProduk Morris
UPC601986941648
ASINB083SQL5SM

8. Garansi jeung Rojongan

For detailed information regarding the product warranty, technical support, or customer service, please refer to the official Morris Products websitus atanapi ngahubungi dukungan palangganna sacara langsung. Simpen resi pameseran anjeun kanggo klaim garansi.

Note: No official product videos from the seller were available for inclusion in this manual.

Dokumén Patali - 94164

Praview Morris Bulanan - Juni 2009 - Morris ngadaptar Newsletter
Morris Bulanan Juni 2009, buletin resmi klub Morris Register, nampilkeun warta klub, carita anggota, artikel téknis, sareng laporan acara pikeun peminat kendaraan Morris.
Praview MORRIS T73344DBN/2 & D73345DBN/2 Ψυγειοκαταψύκτης Εγχειρίδιο Χρήσης
Οδηγίες χρήσης και ασφάλειας για τους ψυγειοκαταψύκτες MORRIS μοντέλα T73344DBN/2 και D73345DBN/2. Βρείτε πληροφορίες για εγκατάσταση, συντήρηση, λειτουργία και αντιμετώπιση προβλημάτων.
Praview Οδηγίες Χρήσης MORRIS RETRO SERIES Φούρνος Μικροκυμάτων
Αναλυτικός οδηγός χρήσης για τον φούρνο μικροκυμάτων MORRIS RETRO SERIES, 20700R/2ματ έως MWRS-20704LB/2. Περιλαμβάνει οδηγίες ασφαλείας, εγκατάστασης, καθαρισμού, λεν,νίρ ελέγχου, συμβουλές μαγειρέματος και οδηγό σκευών.
Praview Manual Pangguna sareng Pituduh Pamasangan Kompor Keramik MORRIS MVD-65352
Dokumén ieu nyayogikeun pitunjuk lengkep pikeun kompor keramik internal MORRIS MVD-65352, kalebet pedoman kaamanan, spésifikasi téknis, prosedur pamasangan, pitunjuk operasi, tip beberesih sareng pangropéa, sareng saran ngungkulan masalah.
Praview Morris LED Floodlight Installation Guide and Safety Instructions
Comprehensive installation guide for Morris LED Floodlights, covering safety warnings, step-by-step instructions, and symbol explanations. Ensure safe and correct setup.
Praview MORRIS T73344DBN/2 D73345DBN/2 Refrigerator User Manual
Comprehensive user manual for MORRIS T73344DBN/2 and D73345DBN/2 refrigerators, covering installation, operation, safety, maintenance, and troubleshooting. Includes detailed instructions and warranty information.