This manual provides essential information for the safe and efficient installation, operation, and maintenance of the BENINCA Gate Opener VN M.20. This system is designed for automating warehouse or heavy garage doors, specifically those installed directly on the shaft (1-inch diameter) without a rail or trolley system. Please read this manual thoroughly before attempting any installation or operation.

2. Parentah Kasalametan penting

WARNING: Failure to follow these safety instructions may result in serious injury or death, and/or damage to property.

3. Produk Langkungview

3.1. komponén

The BENINCA VN M.20 system includes the following main components:

3.2. Fitur

3.3. Visuals produk

BENINCA Gate Opener VN M.20 Motor and Control Panel

Gambar 1: Leuwihview of the BENINCA Gate Opener VN M.20 system, showing the motor unit with its chain drive mechanism and the separate control panel with green operational buttons.

BENINCA Gate Opener VN M.20 Control Panel

Gambar 2: Pahareup-hareup view of the BENINCA Gate Opener VN M.20 control panel, featuring the BENINCA logo and two prominent green buttons for operation.

4. Setup jeung Instalasi

Professional installation is highly recommended for this product. Ensure all safety precautions are followed.

4.1. Pamariksaan Pra-instalasi

4.2. Mounting the Motor Unit

  1. Securely attach the motor base to the wall or ceiling structure using appropriate fasteners. Ensure the base is level and robust enough to support the motor's weight (approximately 60 pounds).
  2. Mount the motor unit onto the base, ensuring it is correctly aligned with the door shaft.
  3. Connect the motor's drive mechanism to the 1-inch door shaft.

4.3. Wiring the Control Panel

  1. Mount the control panel in a secure, accessible location, away from moving parts and potential damage.
  2. Connect the 230 Vac power supply to the designated terminals on the control panel. Refer to the wiring diagram provided with the product packaging for specific connections.
  3. Connect the motor unit to the control panel using the provided cables, ensuring correct polarity and terminal assignments.
  4. If external safety devices (e.g., photocells, safety edges) are used, connect them to the appropriate terminals on the control panel.

4.4. Adjusting Limit Switches

The VN M.20 features adjustable limit switches to define the door's fully open and fully closed positions.

  1. With power applied, manually operate the door to its desired fully open position.
  2. Adjust the 'Open' limit switch on the motor unit or control panel (refer to specific product diagrams) until the door stops precisely at this position.
  3. Repeat the process for the 'Close' limit switch, setting the desired fully closed position.
  4. Test the limits multiple times to ensure consistent and accurate stopping.

5. Parentah Operasi

5.1. Operasi dasar

5.2. Papasangan Jauh Jauh

To pair a new remote control with the integrated receiver:

  1. Locate the 'Learn' or 'Program' button on the control panel (refer to the control panel diagram).
  2. Press and hold the 'Learn' button until an indicator light (LED) illuminates or flashes.
  3. Within a few seconds, press the desired button on your remote control. The indicator light should change or flash differently to confirm successful pairing.
  4. Test the remote control to ensure it operates the gate opener correctly.

6. Pangropéa

Regular maintenance ensures the longevity and safe operation of your BENINCA Gate Opener VN M.20.

6.1. Pamariksaan Rutin (Bulanan)

6.2. beberesih

6.3. Lubrication (Annually or as needed)

7. Cara ngungkulan

This section provides solutions to common issues. For complex problems, contact qualified technical support.

MasalahMungkin Cukang lantarananaSolusi
Motor teu ngabales paréntah.No power supply; Blown fuse; Remote control battery dead; Safety device activated.Check power connection; Replace fuse; Replace remote battery; Check safety sensors for obstructions or misalignment.
Door stops unexpectedly during operation.Obstruction detected; Safety device triggered; Limit switch malfunction.Remove obstruction; Check safety sensors; Inspect and readjust limit switches.
Door does not fully open or close.Limit switches incorrectly set; Door balance issue.Readjust limit switches (Section 4.4); Check door for proper balance and smooth movement.
Sora-sora anu teu biasa tina motor.Lack of lubrication; Worn components; Misalignment.Lubricate moving parts; Inspect for worn gears or bearings; Check alignment of motor and shaft. Contact service if noise persists.

8. Spésifikasi Téknis

FiturRincian
ModélVN M.20
merekBENINCA
ProdusénBénika
Voltage230 Waktos
Item Beurat60 pon
BahanBeusi sténless
Warnapérak
Tipe PamasanganScrew-In
UPC669737589198

9. Garansi jeung Rojongan

For specific warranty details, please refer to the warranty card included with your product packaging or contact your authorized BENINCA dealer. General warranty terms typically cover manufacturing defects for a specified period from the date of purchase.

For technical support, spare parts, or service inquiries, please contact your BENINCA distributor or visit the official BENINCA website for contact information. When contacting support, please have your model number (VN M.20) and purchase date readily available.

Sumberdaya Online: Kanggo inpormasi sareng dukungan tambahan, anjeun tiasa nganjang ka BENINCA official websitus.

Dokumén Patali - VN M.20

Praview Manual Pangguna Sistem Gerbang Geser Otomatis Benincà BISON 35 OTI
Manual pangguna anu lengkep pikeun sistem gerbang geser otomatis Benincà BISON 35 OTI, anu ngawengku pamasangan, spésifikasi, kaamanan, pangropéa, sareng detil téknis pikeun gerbang geser industri dugi ka 3500kg.
Praview Beninca BOB5024 / BOB5024E Gate Automation System User Manual
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Beninca BOB5024 and BOB5024E gate automation systems. It covers safety precautions, technical specifications, wiring diagrams, and troubleshooting.
Praview Beninca BOB50M and BOB5024E Gate Automation Installation and Parts Manual
This manual provides detailed installation instructions, technical specifications, wiring diagrams, and a parts list for the Beninca BOB50M and BOB5024E automatic gate operators. It covers safety guidelines, manual release procedures, and maintenance information.
Praview Beninca KS4 ngageser Gate Automation Kit Instalasi Guide
Pituduh instalasi komprehensif pikeun kit automation Gerbang geser Beninca KS4, nampilkeun unit kontrol CP.MS4. Nyertakeun spésifikasi teknis, ningkatna, wiring, konfigurasi, sarta ngungkulan pikeun automation Gerbang padumukan.
Praview Beninca DU.350N/NV Swing Gate Operator Installation and Maintenance Manual
This document provides installation, technical specifications, and safety guidelines for the Beninca DU.350N and DU.350NV swing gate operators. It details the components, mounting procedures, and maintenance requirements for these automated gate systems.
Praview Beninca BEN24 Knikarm Poortopener en CP.BN Sturing Installatiehandleiding
Uitgebreide installatie- en gebruikershandleiding voor de Beninca BEN24 knikarm poortopener en de CP.BN besturingseenheid. Bevat technische spésifikasi, montage-instructies, aansluitschema urang, programmeeropties en veiligheidsrichtlijnen.