Bubuka
This manual provides essential information for the safe installation, operation, and maintenance of the Satco Nuvo TL104 Track Live End Current Limiter. Please read these instructions thoroughly before installation and retain them for future reference.
Fitur konci:
- Electrifies track systems while limiting current.
- Integrated resettable circuit breaker for overload protection.
- Features a knockout for direct electrical feed.
- Pre-wired leads for simplified connection.
- Designed for 120V, 60Hz Satco track systems.
Émbaran Kasalametan
WARNING: Risk of electric shock. Installation should only be performed by a qualified electrician.
- Always disconnect power at the circuit breaker before installing or servicing the unit.
- Pastikeun sadaya sambungan listrik sasuai sareng kodeu lokal sareng ordinances.
- Ulah ngaleuwihan rating ayeuna maksimum 5 Amps pikeun alat ieu.
- produk ieu dimaksudkeun pikeun pamakéan indoor wungkul.
- Pariksa yén suplai voltage is 120V, 60Hz before connection.
Eusi pakét
- 1 x Satco Nuvo TL104 Track Live End Current Limiter (5 Amps, White)
Setup sareng Instalasi
The TL104 Live End Current Limiter is designed for direct connection to a 120V, 60Hz power source and integration into a Satco track lighting system. An optional canopy plate (Satco SKUs TP212/TP213) may be used for direct junction box mounting.
- Pegatkeun daya: Before beginning any installation, ensure the main power supply to the circuit is turned OFF at the circuit breaker.
- Nyiapkeun Wiring: If using the knockout for direct electrical feed, remove the appropriate knockout. Connect the pre-wired leads from the current limiter to the building's electrical supply wires (black to live, white to neutral, green/bare to ground) according to local electrical codes. Secure connections with approved wire connectors.
- Mounting to Track: Align the live end connector with the end of the track section. Ensure the polarity is correct (usually indicated by markings on the track and connector).
- Sambungan Aman: Push the live end firmly into the track until it clicks into place. Tighten any securing screws on the connector to ensure a stable and continuous electrical connection.
- Optional Junction Box Mounting: If using an optional canopy plate for junction box mounting, follow the instructions provided with the canopy plate to secure the limiter to the junction box and then to the track.
- Cék ahir: Double-check all connections and ensure the unit is securely mounted.
- Mulangkeun Daya: Sakali pamasangan parantos réngsé sareng diverifikasi, balikkeun kakuatan dina pemutus sirkuit.

Image: Close-up of the live end connector for track integration.

Image: Product dimensions for planning installation space.

Gambar: Top view illustrating internal components and wiring access.

Gambar: Tungtung view showing the track connection interface.
Parentah Operasi
The Satco Nuvo TL104 Track Live End Current Limiter functions as a protective device within your track lighting system. Once properly installed and connected to power, it will automatically electrify the track and limit the total current draw to 5 Amps.
- Hurungkeun/Pareuman: The unit features a rocker switch (ON/OFF) to control power to the track system. Toggle the switch to the 'ON' position to supply power to the track and 'OFF' to cut power.
- Watesan ayeuna: The built-in resettable circuit breaker will automatically trip if the total current drawn by the track fixtures exceeds 5 Amps, protecting the system from overload.

Image: ON/OFF rocker switch for controlling power to the track.
Pangropéa
The Satco Nuvo TL104 Track Live End Current Limiter requires minimal maintenance. Regular inspection is recommended to ensure optimal performance and safety.
- beberesih: Ensure power is OFF before cleaning. Wipe the exterior with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Pamariksaan: Periodically check for any signs of physical damage, loose connections, or discoloration. If any issues are found, disconnect power and consult a qualified electrician.
- Pamutus Sirkuit: The built-in circuit breaker is resettable. If it trips, refer to the Troubleshooting section.
Pamérésan masalah
If your track lighting system is not functioning as expected, refer to the following common issues and solutions:
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| No power to track lights. | 1. Saklar kakuatan OFF. 2. Circuit breaker tripped. 3. sambungan listrik leupas. | 1. Ensure the ON/OFF switch on the limiter is in the 'ON' position. 2. Reset the circuit breaker on the limiter (if applicable) or at the main panel. Reduce load if it trips again. 3. Disconnect power and check all wiring connections. Tighten as necessary. |
| Circuit breaker repeatedly trips. | Overload on the track system (total wattage ngaleuwihan 5 Amps). | Ngurangan jumlah atawa wattage of fixtures on the track. Ensure total current draw does not exceed 5 Amps (600 Watts at 120V). |
| Unit is warm to the touch. | Operasi normal dina beban. | This can be normal. If it is excessively hot or emits a burning smell, immediately disconnect power and consult a qualified electrician. |
If troubleshooting steps do not resolve the issue, contact a qualified electrician or Satco customer support.
spésifikasi
| Fitur | Spésifikasi |
|---|---|
| merek | Satco |
| Ngaran modél | TL104 |
| Peunteun ayeuna | 5 Amps |
| Warna | Bodas |
| Bahan | palastik |
| Voltage | 120 volt |
| Frékuénsi | 60 Hz |
| Max Wattage Load | 600 Watts (at 120V) |
| Pamakéan jero rohangan / outdoor | jero rohangan |
| Tipe Pamasangan | Pemasangan di Langit-langit (Sistem Trek) |
| Pindah Tipe | Rocker |
| Dimensi produk | 6.63 x 2.5 x 1.25 inci |
| Item Beurat | 8 ons |
| UPC | 045923511240 |
Garansi
This Satco Nuvo TL104 Track Live End Current Limiter is covered by a 1-taun jaminan kawates from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from improper installation, misuse, abuse, or unauthorized modifications. For warranty claims, please retain your proof of purchase and contact Satco customer support.
Ngarojong
For technical assistance, replacement parts, or further information regarding your Satco Nuvo TL104 Track Live End Current Limiter, please contact Satco customer support through their official websitus atawa inpo kontak disadiakeun kalawan pameseran Anjeun.
Sumberdaya Online: www.satco.com