AI fe439f2e-30b4-4bdd-85ba-076feed9ea82

Detektor Termo Bosch GIS 500 - Buku Panduan Pangguna Detektor Infrabeureum

Model: fe439f2e-30b4-4bdd-85ba-076feed9ea82

1. Bubuka

This user manual provides essential information for the safe and effective operation of the Bosch GIS 500 Thermo Detector. This infrared detector is designed for non-contact temperature measurement, offering precise readings within a wide range. Please read this manual thoroughly before first use and keep it for future reference.

2. Émbaran Kasalametan

Salawasna perhatikeun tindakan pencegahan kaamanan ieu pikeun nyegah tatu sareng karusakan kana alat:

The Bosch GIS 500 utilizes Laser Technology. Observe all warnings related to laser use.

3. Produk Langkungview

The Bosch GIS 500 Thermo Detector is a compact and ergonomic infrared thermometer designed for various applications. It provides immediate temperature readings with a simple press of a button.

Bosch GIS 500 Thermo Detector, front view

Gambar 3.1: Hareupeun view of the Bosch GIS 500 Thermo Detector, showing the display and trigger.

Bosch GIS 500 Thermo Detector with labeled features

Figure 3.2: Bosch GIS 500 with key features highlighted, including wide temperature range, simple operation, compact design, and versatility.

Icons representing functions of Bosch GIS 500

Figure 3.3: Icons illustrating key functions: 2xAA battery, battery indicator, -30°C to +500°C range, D:S=12:1 distance-to-spot ratio, laser technology, and laser warning.

Bosch GIS 500 Thermo Detector and carrying pouch

Figure 3.4: The Bosch GIS 500 Thermo Detector shown alongside its included carrying pouch.

Fitur konci:

4. Setélan

4.1 Ngabongkar bungkusan sareng Inspeksi Awal

Carefully remove the Bosch GIS 500 Thermo Detector and its accessories from the packaging. Verify that all components listed in the "Scope of Delivery" are present and undamaged:

4.2 Pamasangan batré

The Bosch GIS 500 is powered by one 1.5 V LR6 (AA) battery. To install the battery:

  1. Locate the battery compartment cover, typically on the handle of the device.
  2. Buka panutup kompartemen batré.
  3. Insert one 1.5 V LR6 (AA) battery, ensuring correct polarity (+/-) as indicated inside the compartment.
  4. Tutup panutup kompartemen batré aman.

The device features a battery indicator on its display to show the current battery level.

5. Parentah Operasi

5.1 Powering on / Pareum

To power on the device, press the measurement trigger. The display will illuminate. The device will automatically power off after a period of inactivity to conserve battery life.

5.2 Nyandak Pangukuran

The Bosch GIS 500 provides immediate, non-contact temperature measurements:

  1. Point the front of the detector towards the surface you wish to measure. Ensure the laser pointer (if activated) is aimed at the desired spot.
  2. Press and hold the measurement trigger. The device will continuously measure the temperature of the target area.
  3. The temperature reading will be displayed on the easy-to-read illuminated display.
  4. Release the trigger to hold the last measured value on the display.

5.3 Emissivity adjustment

The Bosch GIS 500 allows for the selection of 3 emissivity grades to ensure more accurate measurements for different surface types. Refer to the device's on-screen menu or dedicated button (if available) to cycle through the emissivity settings. Consult a reference table for typical emissivity values of common materials if precise measurements are critical.

5.4 Measurement Range and Distance

The device measures temperatures between -30°C and +500°C. The optimal distance-to-spot ratio (D:S) for this device is 12:1, meaning that at a distance of 12 units, the measurement spot diameter is 1 unit. For example, at 12 inches distance, the spot measured is 1 inch in diameter. Maintain an appropriate distance to ensure accurate readings of the target area.

6. Pangropéa

6.1 beberesih

To maintain the accuracy and longevity of your Bosch GIS 500, keep it clean:

6.2 Panyimpenan

When not in use, store the device in its carrying pouch in a cool, dry place, away from direct sunlight and extreme temperatures. If storing for extended periods, remove the battery to prevent leakage.

7. Cara ngungkulan

This section addresses common issues you might encounter with your Bosch GIS 500 Thermo Detector.

MasalahMungkin Cukang lantarananaSolusi
Alat teu hurung.Batré pareum atawa salah dipasang.Replace the battery or check its polarity.
Bacaan suhu teu akurat.Incorrect emissivity setting; lens is dirty; target is too far or too small.Adjust emissivity setting; clean the lens; move closer to the target or ensure it fills the measurement spot.
Tampilanna taram atawa kedip-kedip.batré lemah.Ganti batréna.
Device only displays Celsius.The device model may not support Fahrenheit display.This model (Bosch GIS 500) is noted to primarily display in Celsius and may not have a Fahrenheit conversion option. Please refer to product specifications at purchase.

Lamun masalah persists sanggeus nyobian solusi ieu, mangga ngahubungan rojongan customer.

8. Spésifikasi

AtributRincian
Nomer modélfe439f2e-30b4-4bdd-85ba-076feed9ea82
merekAI
ProdusénBosch
Rentang Suhu-30°C to +500°C (5E+2 Degrees Celsius)
Sumber DayaBattery Powered (1 x 1.5 V LR6 AA)
WarnaBiru
Ukuran Paket10.47 x 6.42 x 3.46 inci
Item Beurat1.18 pon
Tanggal Sadia munggaran26 April 2022

9. Garansi jeung Rojongan

Please note that this product is a parallel import. While it is authentic and functionally equivalent to officially distributed items, it may not be eligible for manufacturer warranty service in the United States. It may also differ in model number, included accessories, packaging design, user manuals, and warranty coverage compared to products sold in the United States. Please review the product details carefully before purchasing.

For support regarding this product, please refer to the seller or the point of purchase. Keep your proof of purchase for any inquiries.

For general information about Bosch products, you may visit the official Bosch website, however, specific warranty claims for this parallel import model should be directed to your retailer.