FireAngel FA6115-FRT

FireAngel FA6115-FRT Optical Smoke Detector User Manual

Model: FA6115-FRT

1. Bubuka

This manual provides essential information for the installation, operation, and maintenance of your FireAngel FA6115-FRT Optical Smoke Detector. Designed for home and caravan use, this detector features an advanced optical sensor for early detection of slow-burning fires and is a direct replacement for the ST-625 model. Please read these instructions carefully before installation and retain them for future reference.

FireAngel FA6115-FRT Optical Smoke Detector, front view

Gambar 1: Hareupeun view of the FireAngel FA6115-FRT Optical Smoke Detector.

FireAngel FA6115-FRT Optical Smoke Detector, side view

Gambar 2: Sisi view of the FireAngel FA6115-FRT Optical Smoke Detector, showing the ventilation grilles.

2. Émbaran Kasalametan

  • This smoke detector is designed to detect smoke. It cannot prevent fires.
  • Regularly test your smoke detector as described in this manual.
  • Do not paint the smoke detector. Paint can block the smoke entry points and interfere with the sensor's ability to detect smoke.
  • Do not attempt to repair the unit yourself. Refer to the warranty section for service information.
  • Ensure batteries are installed correctly and replaced when indicated by the low battery warning.

3. Eusi Paket

Pastikeun yén sadaya item aya dina pakét anjeun:

  • FireAngel FA6115-FRT Optical Smoke Detector
  • Platform ningkatna
  • 2 x Batré AA
  • Screws and Anchors for installation
  • Manual pangguna (dokumén ieu)
Contents of the FireAngel FA6115-FRT smoke detector package

Figure 3: Package contents including the detector, mounting plate, batteries, and manual.

4. Setup jeung Instalasi

4.1 Milih Lokasi

For optimal protection, install smoke detectors in all rooms, especially bedrooms and hallways leading to sleeping areas. Avoid placing detectors in or near:

  • Kitchens or bathrooms, due to steam and cooking fumes that can cause false alarms.
  • Areas with high humidity or extreme temperatures.
  • Within 50 cm (20 inches) of walls or corners when mounted on the ceiling.
  • Near ventilation outlets or fans that could prevent smoke from reaching the detector.

The FA6115-FRT is an optical smoke detector, highly effective at detecting slow-burning fires, which produce thick, visible smoke. For comprehensive fire safety, consider installing a heat alarm in the kitchen and a carbon monoxide alarm where fuel-burning appliances are present.

Smoke detector installed on a ceiling in a hallway

Gambar 4: Kelample of a smoke detector installed on a ceiling in a hallway, a recommended location.

4.2 Pamasangan Parentah

  1. Nyiapkeun Surface Mounting: Choose a flat ceiling or wall surface. Use the mounting platform as a template to mark the screw holes.
  2. liang bor: Drill two holes at the marked positions. Insert the provided anchors if installing into drywall or plaster.
  3. Attach Mounting Platform: Secure the mounting platform to the ceiling or wall using the provided screws.
  4. Pasang Batré: Open the battery compartment on the back of the detector. Insert the two AA batteries, ensuring correct polarity (+/-).
  5. Pasangkeun Detektor: Align the detector with the mounting platform. Push and twist the detector clockwise until it clicks securely into place.
  6. Tés awal: Press and hold the large 'TEST' button on the front of the detector for a few seconds. The alarm should sound loudly, and the red LED should flash. This confirms the unit is functioning correctly.
Close-up of the smoke detector mounting plate and screw

Figure 5: The removable mounting plate is secured to the ceiling or wall using screws.

Internal view of the smoke detector showing the battery compartment

Figure 6: The battery compartment requires two AA batteries, which are included.

5. Parentah Operasi

5.1 Operasi normal

Under normal operating conditions, the red LED indicator will flash approximately once every 45 seconds to indicate that the detector is powered and functioning correctly.

5.2 Tés / Tombol tiiseun

The large central button serves two primary functions:

  • Uji coba: Press and hold the button for a few seconds to perform a functional test. The alarm will sound, and the red LED will flash rapidly. This should be done monthly.
  • Ngajempékeun: In the event of a known false alarm (e.g., from cooking fumes), press the button briefly to temporarily silence the alarm for approximately 10 minutes. The detector will automatically reset after this period.
Close-up of the smoke detector test button with red LED indicator

Figure 7: The central button is used for testing the alarm and silencing false alarms.

5.3 Sleep Easy™ Function (Low Battery Silence)

If the batteries are low, the detector will emit a short chirp approximately every 45 seconds, accompanied by a red LED flash. If this occurs during the night, you can activate the Sleep Easy™ function:

  • Press the 'TEST' button once. The low battery chirp will be silenced for 8 hours.
  • The red LED will continue to flash, indicating the low battery status.
  • Even in Sleep Easy™ mode, the detector remains active and will sound the alarm if smoke is detected.
  • Replace the batteries as soon as possible, ideally within 30 days of the first low battery warning.
Diagram illustrating the Sleep Easy function for silencing low battery chirps

Figure 8: The Sleep Easy function allows temporary silencing of low battery chirps for 8 hours.

Diagram showing the optical sensor detecting smoke particles

Figure 9: The optical sensor detects smoke particles entering the chamber, providing rapid detection for slow-burning fires.

6. Pangropéa

6.1 Monthly Testing

Test your smoke detector at least once a month by pressing and holding the 'TEST' button until the alarm sounds. This ensures the unit is functioning correctly.

6.2 beberesih

Dust and debris can accumulate on the detector, potentially affecting its performance. Clean your smoke detector every 3-6 months:

  • Gently vacuum around the detector's casing and ventilation openings using a soft brush attachment.
  • Do not use cleaning sprays or solvents on the detector.

6.3 Ngagantian batré

The FA6115-FRT uses two replaceable AA batteries with a typical lifespan of 5 years. When the low battery warning sounds (chirp every 45 seconds), replace both batteries immediately. Refer to Section 4.2 for battery installation steps.

7. Cara ngungkulan

MasalahMungkin Cukang lantarananaSolusi
Detector chirps every 45 secondsbatré lemahReplace both AA batteries immediately. Use Sleep Easy™ function if chirping occurs at night.
False alarms (e.g., during cooking)Detector too close to kitchen/bathroom, steam, or cooking fumes.Press the 'TEST' button to silence for 10 minutes. Relocate the detector if false alarms persist due to placement. Ensure proper ventilation during cooking.
Alarm henteu disada nalika tésNo power, faulty unit, or incorrect battery installation.Check battery installation and replace if necessary. If the problem persists, the unit may be faulty and requires replacement.
LED beureum teu kedip-kedipTaya kakuatan atawa unit faulty.Ensure batteries are correctly installed and charged. If the issue persists, the unit may be faulty.

8. Spésifikasi

FiturRincian
Nomer modélFA6115-FRT
Tipe sénsorOptical (Photoelectric)
Sumber Dayabatré powered
Batré2 x AA (included, replaceable)
Komposisi batréAlkali
Hirup sénsor10 taun
Ukuran produk (L x W x H)11.81 x 11.81 x 3.15 cm
diaméterna118.1 mm
Beurat70 gram
Bahanpalastik
WarnaBodas
Métode PamasanganWall or Ceiling (screws and anchors provided)
Suhu OperasiNepi ka 38 ° C
Kalembaban OperasiNepi ka 90% RH (non-condensing)
SertifikasiCE certified, EN 14604:2005+AC:2008 compliant
Technical drawing of the smoke detector with dimensions

Figure 10: Technical drawing showing the dimensions of the FireAngel FA6115-FRT detector.

9. Garansi jeung Rojongan

9.1 Garansi Produsén

The FireAngel FA6115-FRT Optical Smoke Detector comes with a 10-taun jaminan produsén urang ti tanggal beuli. Garansi ieu nyertakeun cacad dina bahan sareng pagawean dina panggunaan normal. Punten tahan bukti pameseran anjeun pikeun klaim garansi.

9.2 Rojongan Palanggan

If you experience any issues with your smoke detector that cannot be resolved using the troubleshooting guide, or for warranty inquiries, please contact FireAngel customer support. Refer to the FireAngel official websitus atawa bungkusan produk pikeun inpo kontak panganyarna.

Catetan: Do not attempt to open or repair the unit yourself, as this may void the warranty and compromise the device's safety features.

Dokumén Patali - FA6115-FRT

Praview FireAngel FA6111, FA6115, FA6120 Smoke Alarms & FA6215 Heat Alarm User Manual
Comprehensive user manual for FireAngel FA6111, FA6115, FA6120 optical smoke alarms and FA6215 heat alarm, covering installation, maintenance, troubleshooting, features like Silence and Sleep Easy, warranty, and disposal.
Praview Buku Panduan Pangguna Alarm Haseup FireAngel ST-625-INT
Buku panduan lengkep pikeun alarm haseup FireAngel ST-625-INT, anu ngawengku pamasangan, fitur, pangropéa, sareng garansi. Buku panduan ieu nyayogikeun inpormasi kaamanan penting sareng pitunjuk operasional.
Praview Manual Pangguna Alarm Haseup sareng Panas FireAngel: FA6611, FA6615, FA6620, FA6720
User manual for FireAngel Optical Smoke Alarms (FA6611, FA6615, FA6620) and Heat Alarms (FA6720). Provides detailed information on positioning, installation, maintenance, troubleshooting, silence and sleep easy features, warranty, and disposal instructions for ensuring home fire safety.
Praview Buku Panduan Pangguna Alarm Haseup & Panas FireAngel: FA6611, FA6615, FA6620, FA6720
Buku pituduh lengkep pikeun alarm haseup optik FireAngel FA6611, FA6615, FA6620 sareng alarm panas FA6720. Ngawengku pamasangan, pangropéa, ngungkulan masalah, garansi, sareng pembuangan.
Praview FireAngel FA6611, FA6615, FA6620 Smoke & FA6720 Heat Alarm User Manual
User manual for FireAngel FA6611, FA6615, FA6620 optical smoke alarms and FA6720 heat alarm. Includes installation, positioning, maintenance, troubleshooting, warranty, and disposal information.
Praview FireAngel: Important Information for Home Occupiers on Fire Detection and Alarm Systems
Guidance for homeowners on using, maintaining, and understanding FireAngel fire detection and alarm systems, including actions during alarms, avoiding false alarms, and routine checks.