1. Bubuka
This manual provides detailed instructions for the safe and effective operation of the GVDA GD166B True RMS Digital Clamp Meter. This high-performance smart digital clamp meter is designed to simplify and enhance your electrical measurement tasks. It integrates a wide range of functions, making it an essential tool for professionals and enthusiasts alike.
The GD166B is capable of measuring AC/DC voltage, AC/DC current, frequency, duty cycle, resistance, capacitance, temperature, diode, continuity, NCV (Non-Contact Voltage) detection, live wire detection, and more.
2. Émbaran Kasalametan
WARNING: To avoid electric shock or personal injury, read and understand all safety information before using this product.
- Salawasna taat kana kode kaamanan lokal jeung nasional.
- Do not use the meter if it appears damaged or if the insulation is compromised.
- Ulah nerapkeun leuwih ti dipeunteun voltage, sakumaha ditandaan dina méter, antara terminal atawa antara sagala terminal jeung taneuh taneuh.
- Paké caution nalika gawé bareng voltagdi luhur 30V AC RMS, puncak 42V, atanapi 60V DC. Voltase sapertos kitutagÉta nyababkeun bahaya shock.
- Cabut lead test tina sirkuit sateuacan ngarobah fungsi.
- Ensure the battery cover is closed and secured before operation.
- Do not operate the meter with the battery compartment open.
- Ganti batré pas indikator batré lemah nembongan.
- Ulah make méter dina gas ngabeledug, uap, atawa lingkungan berdebu.
- Anggo terminal, fungsi, sareng rentang anu pas pikeun pangukuran anjeun.
3. Produk Langkungview
The GVDA GD166B is a versatile digital clamp meter designed for accurate and reliable electrical measurements. Below are its key features and components.
3.1 Fitur konci
- Pangukuran RMS anu leres pikeun bacaan anu akurat dina bentuk gelombang non-sinusoidal.
- Ukur AC/DC Voltage, AC/DC Current, Resistance, Capacitance, Frequency, and Temperature.
- Fungsi Uji Dioda sareng Uji Kontinuitas.
- Non-Kontak Voltage (NCV) detection and Live Wire detection for enhanced safety.
- AC Inrush Current measurement.
- Smart Measurement (Auto) mode for simplified operation.
- Data Hold, Backlight, and Flashlight functions.
- Large LCD display with 6000 counts.
- Compact and ergonomic design with a 36mm clamp bubuka.
3.2 Komponén

Gambar 3.2.1: Hareupeun View of the GD166B Clamp Méter. This image shows the main unit of the GVDA GD166B digital clamp meter along with its red and black test leads. The large display, function buttons, and the clamp jaw are clearly visible.

Figure 3.2.2: GVDA GD166B with Brand Logo. A ngadeukeutan view of the GD166B clamp meter, highlighting the GVDA brand logo and model number on the device's body.

Figure 3.2.3: AC/DC Clamp Meter Comparison. This image displays two GVDA clamp meters, GD168B and GD166B, side-by-side, showcasing their similar design and functionality as AC/DC clamp méter.

Gambar 3.2.4: Eusi Paket. This image shows the complete package contents, including the GD166B clamp meter, test leads, a thermocouple probe, a carrying case, and the user manual.
4. Setélan
4.1 Pamasangan batré
The GD166B requires 3 x 1.5V AAA batteries (not included) for operation.
- Teang kompartemen batré dina tonggong méter.
- Paké obeng pikeun muka panutup kompartemen batré.
- Insert three AAA batteries, ensuring correct polarity (+ and -).
- Ganti panutup kompartemen batré jeung amankeun ku screw nu.
4.2 Nyambungkeun Test Leads
Pikeun pangukuran anu meryogikeun uji lead (contona, voltage, resistance, continuity, diode, capacitance, temperature), connect them as follows:
- Selapkeun kabel tés hideung kana jack input "COM" (umum).
- Insert the red test lead into the "INPUT" (positive) input jack.

Figure 4.2.1: Test Lead Connection. This image illustrates the correct way to connect the test leads to the meter's input jacks for various measurements.
5. Parentah Operasi
5.1 Daya Hurung/Pareuman
Pencét éta Tombol daya (⑂) to turn the meter on or off.
5.2 Pamilihan Fungsi
The GD166B features a "Smart Measurement (Auto)" mode, which automatically identifies the measurement type (voltage, resistance, continuity) when test leads are connected. For other specific functions, use the FUNC button to cycle through modes or the rotary dial if present (though this model appears button-driven).
5.3 Common Measurements
5.3.1 AC/DC Voltage Pangukuran
- Connect the red test lead to the "INPUT" jack and the black test lead to the "COM" jack.
- Pilih vol anu cocogtage range (or use Smart Auto mode).
- Sambungkeun kabel tés sacara sajajar jeung sirkuit atawa komponén anu rék diukur.
- Baca voltage nilai dina tampilan.
5.3.2 Pangukuran Arus AC/DC (Clamp)
For current measurements, use the clamp jaw. Ensure the circuit is de-energized before clamping.
- Select the AC or DC current function.
- Buka clamp jaw and enclose only one conductor of the circuit.
- Tutup clamp rahang sagemblengna.
- Baca nilai ayeuna dina tampilan.
5.3.3 Résistansi Ukur
- Pastikeun sirkuit geus dipareuman énergina sateuacan ngukur résistansi.
- Connect the test leads to the "INPUT" and "COM" jacks.
- Select the resistance function.
- Sambungkeun lead test kana komponén anu bakal diukur.
- Maca nilai résistansi dina tampilan.
5.3.4 Tés Continuity
- Pastikeun sirkuit de-energized.
- Connect the test leads to the "INPUT" and "COM" jacks.
- Select the continuity function.
- Sambungkeun kabel tés ka sakuliah sirkuit atanapi komponén. Bunyi bip anu terus-terusan nunjukkeun kontinuitas (résistansi rendah).
5.3.5 Non-Kontak Voltage (NCV) Deteksi
Fungsi NCV ngamungkinkeun pikeun ngadeteksi voltase ACtage tanpa kontak langsung.
- Pilih fungsi NCV.
- Place the top end of the meter near the conductor or outlet.
- The meter will beep and the NCV indicator will light up if AC voltage dideteksi.

Figure 5.3.5.1: NCV Measurement in Progress. This image demonstrates the GD166B clamp meter being used to perform a Non-Contact Voltage (NCV) measurement on an electrical outlet, indicating its ability to detect live voltage tanpa kontak fisik.
5.3.6 AC Inrush Current Measurement
This function measures the initial surge of current when a device is turned on.
- Select the Inrush Current function.
- Buka clamp jaw and enclose only one conductor of the circuit.
- Turn on the device to be measured. The meter will capture the peak inrush current.

Figure 5.3.6.1: Inrush Current Measurement. This image shows the GD166B clamp meter actively measuring inrush current on a set of electrical wires, demonstrating its capability to capture transient current peaks.
5.3.7 Fungsi séjén
- Tahan Data: Pencét éta TAHAN tombol pikeun ngabekukeun bacaan ayeuna dina tampilan. Pencét deui pikeun ngaleupaskeun.
- MAX / Mnt: Pencét éta MAX/MIN button to record the maximum and minimum readings.
- Lampu tukang/Senter: Pencét éta Tombol lampu to turn on/off the display backlight or the integrated flashlight.
- DCA Zero: Used to zero out the DC current reading before measurement to ensure accuracy.
6. Pangropéa
6.1 beberesih
Ngusap kasus kalayan iklanamp lawon sareng deterjen hampang. Entong nganggo bahan abrasif atanapi pangleyur. Jaga terminal input bébas tina kokotor atanapi kalembaban.
6.2 Ngagantian batré
When the low battery indicator (ikon batré) appears on the display, replace the batteries immediately to ensure accurate readings. Refer to Section 4.1 for battery installation instructions.
6.3 Panyimpenan
Upami méteran ieu teu bade dianggo kanggo waktos anu lami, cabut batréna pikeun nyegah bocor sareng karusakan kana méteran. Simpen méteran ieu di tempat anu tiis sareng garing, jauh tina sinar panonpoé langsung sareng suhu anu ekstrim.
7. Cara ngungkulan
| Masalah | Mungkin Cukang lantaranana | Solusi |
|---|---|---|
| Méter teu hurung. | Batré paéh atawa salah dipasang. | Pariksa polaritasna batré; ngaganti accu. |
| "OL" displayed. | Overload or out of range. | Select a higher range (if applicable) or ensure the measured value is within the meter's limits. |
| Bacaan teu akurat. | Low battery; incorrect function/range; poor test lead connection. | Replace batteries; select correct function/range; ensure secure test lead connection. |
| Taya bip continuity. | Circuit not continuous; high resistance; meter not in continuity mode. | Check circuit; ensure resistance is low; select continuity mode. |
8. Spésifikasi
| Parameter | Range/Nilai |
|---|---|
| DC Voltage | 600mV, 6V, 60V, 600V |
| AC Voltage | 600mV, 6V, 60V, 600V |
| AC Ayeuna | 60A, 600A |
| DC Ayeuna | 60A, 600A |
| Résistansi | 600Ω, 6kΩ, 60kΩ, 600kΩ, 6MΩ, 60MΩ |
| Arus Masuk AC | 60A, 600A |
| Kapasitansi | 6nF, 60nF, 600nF, 6µF, 60µF, 600µF, 6mF, 60mF |
| Frékuénsi | 100Hz, 1000Hz, 10kHz, 100kHz, 1000kHz, 10MHz |
| Siklus tugas | 1-99% |
| Suhu | -40℃ ~ 1000℃, -40℉ ~ 1832℉ |
| Max. Voltage antara terminal jeung Bumi Ground | 600V |
| tampilan | 6000 cacah |
| Over Range Indikasi | "OL" |
| Indikasi Batré Lemah | Sumuhun |
| Input Polarity Indication | Display "-" |
| Clamp Ukuran Bubuka | 36 mm |
| Sarat kakuatan | Batré 3x 1.5V AAA |
| Ukuran produk | 199 * 81 * 32 mm |
| Beurat (Pakét) | 440g |
9. Garansi jeung Rojongan
This product is manufactured to high-quality standards. For information regarding warranty coverage, technical support, or service, please refer to the documentation provided with your purchase or contact your retailer.
Punten tahan bukti pameseran anjeun pikeun klaim garansi.