VENTS Frigate ERV 80 Energy Recovery Ventilator User Manual

Model: Frigate ERV 80 | Brand: VENTS

1. Bubuka

The VENTS Frigate ERV 80 is a whole-house energy recovery ventilation system designed to provide a continuous supply of fresh air while exhausting an equal amount of stale air. This system helps maintain indoor air quality and recover energy from the outgoing air stream, contributing to a more comfortable and energy-efficient living environment.

2. Émbaran Kasalametan

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in property damage, personal injury, or death.

  • Sok pegatkeun sambungan listrik sateuacan ngalayanan atanapi ngabersihkeun unit.
  • Pamasangan sareng perawatan kedah dilaksanakeun ku tanaga anu mumpuni saluyu sareng sadaya kode sareng peraturan lokal.
  • Ulah ngoperasikeun unit ieu upami kabel atanapi komponénna rusak.
  • Pastikeun grounding ditangtoskeun pikeun nyegah shock listrik.
  • Keep foreign objects away from air inlets and outlets.

3. Produk Langkungview

The Frigate ERV 80 unit is a compact and efficient energy recovery ventilator. Key components include:

  • Enthalpy Core: Facilitates heat and humidity transfer between incoming and outgoing air streams without requiring drainage.
  • Integrated Control Board: Allows independent adjustment of supply and exhaust fan speeds from 0% to 100%.
  • Fans: High-efficiency fans for optimal airflow.
  • saringan: (e.g., MERV13, if applicable) for air purification.
  • Automatic Recirculation Dampeh: Provides anti-freeze protection.
VENTS Frigate ERV 80 Energy Recovery Ventilator, front-side view

Gambar 1: Pahareup-hareup view of the VENTS Frigate ERV 80 unit, showing the main casing and power cord.

VENTS Frigate ERV 80 Energy Recovery Ventilator, top view kalayan panel kontrol

Gambar 2: Puncak view of the VENTS Frigate ERV 80, displaying the closed casing and the integrated control panel.

4. Setup jeung Instalasi

The Frigate ERV 80 is designed for quick and easy mounting, particularly suitable for ceiling installation in limited spaces. An included bracket system facilitates the installation process.

4.1 Daptar pariksa Pra-Pamasangan

  • Verify that the installation location provides adequate clearance for maintenance and airflow.
  • Pastikeun catu dayana cocog sareng sarat unit (120 Volt, 72 Watt).
  • Confirm all necessary ductwork and mounting hardware are available.
  • Consult local building codes and regulations for ventilation system installation.

4.2 Pasang Unit

  1. Securely attach the provided mounting brackets to a sturdy structural element (e.g., ceiling joists).
  2. Carefully lift and position the ERV unit onto the brackets, ensuring it is level and stable.
  3. Fasten the unit to the brackets using appropriate hardware.

4.3 Sambungan Saluran

Connect the supply and exhaust ducts to the corresponding ports on the ERV unit. Ensure all connections are sealed to prevent air leakage.

VENTS Frigate ERV 80 Energy Recovery Ventilator, side view némbongkeun sambungan saluran

Gambar 3: Samping view of the VENTS Frigate ERV 80, illustrating the circular ports for duct connections.

4.4 Sambungan Listrik

  • Connect the unit to a dedicated 120V AC power supply.
  • Pastikeun sadaya sambungan listrik saluyu sareng kode listrik lokal.
  • The unit is equipped with a power cord for direct connection.

5. Parentah Operasi

The Frigate ERV 80 features an integrated control board for precise airflow management.

5.1 Mimiti Power-Up

  1. After completing installation, restore power to the unit.
  2. Unit éta bakal ngalaksanakeun pamariksaan mandiri.

5.2 Adjusting Fan Speeds

The integrated control board allows independent adjustment of both supply and exhaust fan speeds from 0% to 100%. Refer to the control board interface for specific adjustment procedures. This flexibility enables optimization of airflow based on specific ventilation needs and external conditions.

5.3 Anti-Freeze Protection

The unit is equipped with an automatic recirculation damper for anti-freeze protection, ensuring continuous operation even in colder climates by temporarily recirculating a portion of the exhaust air to prevent frost buildup on the enthalpy core.

6. Pangropéa

Regular maintenance ensures optimal performance and longevity of your VENTS Frigate ERV 80 unit.

6.1 Filter ngagantian

The unit utilizes filters (e.g., MERV13) to maintain air quality. Filters should be inspected every 3 months and replaced every 6-12 months, or more frequently depending on air quality and usage.

  1. Pegatkeun sambungan kakuatan ka unit.
  2. Open the access panel (refer to Figure 4 for internal view).
  3. Leupaskeun saringan heubeul tur buang aranjeunna leres.
  4. Insert new, clean filters, ensuring they are correctly seated.
  5. Close the access panel and restore power.
VENTS Frigate ERV 80 Energy Recovery Ventilator, internal view showing enthalpy core and filters

Gambar 4: Internal view of the VENTS Frigate ERV 80, showing the enthalpy core and filter compartments.

6.2 Enthalpy Core Cleaning

The enthalpy core typically does not require drainage. However, periodic inspection and gentle cleaning (e.g., vacuuming) may be necessary to remove dust buildup. Refer to the manufacturer's guidelines for detailed cleaning instructions.

6.3 beberesih umum

Usap bagian luar unit nganggo iklanamp lawon. Ulah make cleaners abrasive atawa pangleyur.

7. Cara ngungkulan

This section addresses common issues you might encounter with your Frigate ERV 80 unit.

MasalahMungkin Cukang lantarananaSolusi
Unit teu hurungNo power supply; tripped circuit breaker; loose electrical connection.Check power outlet and circuit breaker. Ensure power cord is securely plugged in. Consult a qualified electrician if issues persist.
Ngurangan aliran hawaClogged filters; blocked ducts; fan speed set too low.Inspect and replace filters. Check ducts for obstructions. Increase fan speed via the control board.
Sora kaleuleuwihiLoose mounting; fan imbalance; foreign object in fan; duct vibration.Ensure unit is securely mounted. Check for any obstructions in the fan. Inspect ductwork for proper installation and insulation. If noise persists, contact customer support.
No heat/humidity recoveryDamaged enthalpy core; incorrect settings.Verify operating settings. If the issue continues, the enthalpy core may require inspection by a professional.

For problems not listed here, or if solutions do not resolve the issue, please contact VENTS customer support.

8. Spésifikasi

Detailed technical specifications for the VENTS Frigate ERV 80.

VENTS Frigate ERV 80 Energy Recovery Ventilator, dimension diagram

Gambar 5: Dimensional diagram for the VENTS Frigate ERV 80, showing key measurements.

FiturRincian
merekKULIAH
ModélFrigate ERV 80
Warnapérak
Dimensi produk55.88 x 53.34 x 22.86 cm (22 x 21 x 9 inci)
Beurat15.6 kg (34.4 lbs)
Wattage72 watt
Voltage120 volt
Tingkat Noise1.4 Sareng
Dianjurkeun MangpaatAir Circulation, Exhausting, Ventilation
Fitur hususAdjustable Height (referring to installation flexibility), Enthalpy Core, Integrated Control Board, Anti-freeze Protection
Alat nu cocogAM 125 VRF, KOM 125 U, MERV13 Filter
Kapasitas Aliran Udara85 to 178 CFM (as per feature bullet, product title mentions 80 CFM, but the feature bullet is more specific about the range)

9. Garansi jeung Rojongan

Specific warranty details are not provided in this manual. For warranty information, technical support, or to purchase replacement parts, please contact VENTS customer service directly or visit their official website. Please have your model number (Frigate ERV 80) and purchase date available when contacting support.